Tester Petroleum Equipment BJL1BA1 (BPTL-218)

Fully Automatic Quenching Medium Cooling Performance Tester
  • Sea, Air, Door to Door Shipping
  • 1 Year Warranty
  • US & European Standards



Tester Petroleum Equipment SH/T 0220, JIS K2242 (or optionally ISO 9950) Electric heating wire

Specifications

ModelBJL1BA1
Applicable StandardsSH/T 0220, JIS K2242 (or optionally ISO 9950)
Heating MethodElectric heating wire
Temperature Control Range80 ± 2°C, 810 ± 2°C
Control MethodDigital Display PID Automatic Temperature Control
Temperature Control Accuracy0.5%
Displayed DataProcess curve, cooling rate curve, characteristic temperature
Result DeterminationAutomatic calculation
Operating EnvironmentIndoor use only
Temperature0 ~ 45°C
Relative Humidity≤ 80%
Power SupplyAC 220V ±10% / 50Hz
Total Power< 2 kW
Dimensions415 x 455 x 700 mm³
Net Weight< 40 kg

Description

This instrument is a fully computer-automated product that replaces earlier chart
recorders. It simplifies operation, reduces manual procedures, and ensures more
accurate results. The system consists of a main unit, a computer-controlled automatic
testing system, a heating furnace, and a stirring system. Users only need to place the
sample into the test cup and press the "Start" key on the computer; the instrument will
automatically measure and save the results.
Over the years, testing methods for quenching media have evolved from the magnetic
method, five-second method, and hot wire method to today's cooling curve method,
transitioning from relative backwardness to advanced technology and becoming
increasingly scientific and rational. The introduction of computer-automated testing
has further perfected this technology, enabling fast, precise, and reliable evaluation.

Features

Microcomputer temperature control system automatically detects the laboratory temperature and calculates the heating rate
based on the working environment to ensure temperature accuracy.
The instrument housing is made of cold-rolled steel plate, treated with electrostatic spraying and high-temperature baking for easy
cleaning and corrosion resistance.
The high-temperature furnace uses Swiss-imported electric heating wires as heating elements, ensuring uniform temperature and
long service life.
The furnace chamber features an 8-hole cyclic heating , avoiding the common issue of heating wire burnout.
The furnace body is made of stainless steel.
The low-temperature furnace uses mold-formed construction and aluminum bath conduction to prevent samples from splashing
into the heater and causing fires.
The furnace chamber connection adopts a standard slide rail design, allowing sliding for easy maintenance.
The inner holes of the furnace chamber are equipped with anti-signal interference slots to prevent electromagnetic interference
during testing, which could disrupt data collection by the silver probe.
Standard test probe testing complies with experimental standards.
Automatic test probe release requires no manual intervention.
When the furnace temperature reaches the set value, the computer prompts automatically and initiates the test.
Testable media: oils, water, quenching fluids, salt-alkali solutions, rolling cooling fluids, cutting fluids, etc.
Data acquisition uses a high-speed data acquisition card.
The instrument features an overtemperature alarm function.
Results are displayed in both curve and data formats.
Parameters are adjustable.
Stirring rate can be adjusted for different samples.
Capable of storing 500 sets of result data.
Allows simultaneous comparison of three sets of test curves.
Enables querying of any temperature or time data from the test.




Request Quote
Name*:
Email*:
I am *: Distributor End User Others
WhatsApp :
Product :
Subject :
Message :