Tissue Embedding System
Embedding is a fixation process during which tissues or the specimens of interest are entrapped in the embedding media. The choice of the media depends on type of tissue, type of microtome and types of microscope to examine the tissue.
(9) items
Go
Series : 600
Main Console Nominal supply voltage : 220 V / 50 Hz220 V / 50 Hz or 110 V / 60 Hz6 LAmbient~100 ℃150x220 mmAmbient to 90 °C (constant adjusting)Ambient to 90 °C (constant adjusting).510×340×220 mm (WxDxH)2.5 L
Tissue Embedding System BHTP-601
- Main Console Nominal supply voltage: 220 V / 50 Hz
- Main Console Maximum power draw: 800-1000 W
- Main Console Working temperature: From ambient to 99 ℃ increments 1 ℃
- Main Console Capacity Paraffin reservoir: 6.0 Lt
- Main Console Capacity Cassette/mold tray: 1.6 Lt
Tissue Embedding System BHTP-602
- Main Console Nominal supply voltage: 220 V / 50 Hz or 110 V / 60 Hz
- Main Console Maximum power draw: 600-800 W
- Main Console Working temperature: Ambient to 99℃
- Main Console Increments: 1 centigrade
- Main Console Capacity Paraffin reservoir: 3.2 L
Tissue Embedding System BHTP-603
- Main Console Wax cylinder volume: 6 L
- Main Console Heater temperature setting range: Ambient to 99 ℃
- Main Console Temperature for the heat preservation tank: ambient to 99 ℃
- Main Console Temperature for the operation table: ambient to 99 ℃
- Main Console Working environmental temperature: 0 ℃ - 45 ℃
Paraffin Dispenser BHTP-604
- Range of temperature: Ambient~100 ℃
- Precision: ± 1 %
- Voltage: AC 110 V 60 Hz
- Power: 1200 VA
- Capacity: 10000 ml
Paraffin Trimmer BHTP-605
- Working area dimension: 150x220 mm
- Temperature range: Ambient to 75 ℃
- Temperature control accuracy: ± 1 ℃
- Supply voltage: 220 V ± 10 % 50 / 60 Hz OR 110 V ± 10 % 50 / 60 Hz
- Max power: 240 W
Tissue Water Bath BHTP-606
- Range of setting temperature: Ambient to 90 °C (constant adjusting)
- Temperature precise error: + 2 °C
- Allowance ambient temperature: 0 – 40 °C
- Working voltage: 220 V / 50 Hz
- Power: 250 W
Tissue Baking Processor BHTP-607
- Range of setting temperature: Ambient to 90 °C (constant adjusting).
- Temperature precise error: + 2 °C.
- Allowance ambient temperature: 0 – 40 °C
- Working voltage: 220 V / 50 Hz
- Power: 250 W
Tissue Flotation Workstation BHTP-608
- Dimension: 510×340×220 mm (WxDxH)
- Dimension of Water Bath: 190×140×70 mm (WxDxH)
- Temperature control range: Three parts all adjustable from 30 – 90 ℃, automatic constant temperature
Tissue Floating Water Bath BHTP-609
- Capacity: 2.5 L
- Temperature range: RT to 75 ˚ C
- Outside Size: 270x210 mm (D)x(H)
- Interior Size: 210x65 mm (D)x(H)
- Power consumption: 400 W