Chromatography

Chromatography

 

 
(10) items
Compare Selected (0)
Go
Series : 100
Ion Chromatographic Pump: Type : High-pressure and low-pulse two-piston tandem advection pumpHigh-pressure and low-pulse two-piston tandem advection pumpHigh-pressure and low-pulse two-piston tandem advection pumpHigh-pressure and low-pulse two-piston tandem advection pump35 Mpa (PEEK)High-pressure and low-pulse two-piston tandem advection pump15°C – 399°C above room temperature (increment: 1°C)22 LAmbient temperature +7°C ~ 400°C (in 1°C increment)Split / Splitless
Ion Chromatography BCHR-101

Ion Chromatography BCHR-101

  • Ion Chromatographic Pump: Type: High-pressure and low-pulse two-piston tandem advection pump
  • Ion Chromatographic Pump: Maximum Pressure: 42 Mpa (Stainless steel)
  • Ion Chromatographic Pump: Pressure Display Accuracy: ≤ 0.1 MPa
  • Ion Chromatographic Pump: Flow Range: 0.001 ~ 9.999 mL/min
  • Ion Chromatographic Pump: Pressure Fluctuation: ≤ 0.5%
Ion Chromatography BCHR-102

Ion Chromatography BCHR-102

  • Ion Chromatographic Pump: Type: High-pressure and low-pulse two-piston tandem advection pump
  • Ion Chromatographic Pump: Maximum Pressure: 35 Mpa (PEEK)
  • Ion Chromatographic Pump: Pressure Display Accuracy: ≤ 0.1 MPa
  • Ion Chromatographic Pump: Flow Range: 0.001 ~ 9.999 mL/min
  • Ion Chromatographic Pump: Pressure Pulse: ≤ 0.5%
Ion Chromatography BCHR-103

Ion Chromatography BCHR-103

  • Ion Chromatographic Pump: Type: High-pressure and low-pulse two-piston tandem advection pump
  • Ion Chromatographic Pump: Maximum Pressure: 35 Mpa (PEEK)
  • Ion Chromatographic Pump: Pressure Display Accuracy: ≤ 0.1 MPa
  • Ion Chromatographic Pump: Flow Range: 0.001 ~ 9.999 mL/min
  • Ion Chromatographic Pump: Flow Precision: ≤ 0.1%
Ion Chromatography BCHR-104

Ion Chromatography BCHR-104

  • Ion Chromatographic Pump: Type: High-pressure and low-pulse two-piston tandem advection pump
  • Ion Chromatographic Pump: Maximum Pressure: 35 Mpa (PEEK)
  • Ion Chromatographic Pump: Pressure Display Accuracy: ≤ 0.1 MPa
  • Ion Chromatographic Pump: Flow Range: 0.001 ~ 9.999 mL/min
  • Ion Chromatographic Pump: Pressure Pulse: ≤ 0.5%
Ion Chromatography BCHR-105

Ion Chromatography BCHR-105

  • Ion Chromatographic Pump: Maximum Pressure: 35 Mpa (PEEK)
  • Ion Chromatographic Pump: Pressure Display Accuracy: ≤ 0.1 MPa
  • Ion Chromatographic Pump: Flow Range: 0.001 ~ 9.999 mL/min
  • Ion Chromatographic Pump: Resolution of Flow Rate: 0.001 ml
  • Ion Chromatographic Pump: Flow Precision: < 0.1%
Portable Ion Chromatography BCHR-106

Portable Ion Chromatography BCHR-106

  • Ion Chromatographic Pump: Type: High-pressure and low-pulse two-piston tandem advection pump
  • Ion Chromatographic Pump: Maximum Pressure: 35 Mpa (PEEK)
  • Ion Chromatographic Pump: Flow Range: 0.001 ~ 9.999 mL/min
  • Ion Chromatographic Pump: Flow Accuracy: ±0.5%
  • Ion Chromatographic Pump: Flow Repeatability: RSD≤0.1%
Gas Chromatography BCHR-107

Gas Chromatography BCHR-107

  • Column Oven: Temperature Range: 15°C – 399°C above room temperature (increment: 1°C)
  • Column Oven: Temperature Control Accuracy: Better than ± 0.1°C (measured at 200°C)
  • Hydrogen flame ionization detector (FID): Detection limit: Dt ≤ 1x10-10 g/s (octane and hexadecane)
  • Hydrogen flame ionization detector (FID): Baseline drift: ≤ 2x10– 12 A/h
  • Hydrogen flame ionization detector (FID): Linear range: ≥ 106
Gas Chromatography BCHR-108

Gas Chromatography BCHR-108

  • Column Oven: Inner volume: 22 L
  • Column Oven: Temperature Range: 5°C – 400°C (room temperature)
  • Column Oven: Temperature Control Accuracy: ± 0.1°C
  • Column Oven: Heating Rate: 0.1 - 60°C /min
  • Column Oven: The order of heating of the program: 9
Gas Chromatography BCHR-109

Gas Chromatography BCHR-109

  • Column Oven: Temperature Range: Ambient temperature +7°C ~ 400°C (in 1°C increment)
  • Column Oven: Temperature Control Accuracy: ± 0.02°C
  • Column Oven: Programmed temperature setting: 0.1°C ~ 40°C/min (in 1°C increment)
  • Column Oven: Program ramps: 7 ramps in total (10 ramps available with control workstation)
  • Column Oven: Cooling time: 400°C to 50°C in 8-10 min at 25°C ambient
Gas Chromatography-Mass Spectrometry BCHR-110

Gas Chromatography-Mass Spectrometry BCHR-110

  • GC Specification: Inlet: Split / Splitless
  • GC Specification: Inlet Temperature: Highest temperature 450°C
  • GC Specification: Electronic Pressure Control(EPC)Range: 0-50 Psi, accuracy 0.1 Psi, support constant
  • GC Specification: Maximum Diffluent Ratio: 500:1
  • GC Specification: Working Temperature in column oven: +10°C - 450°C