Meters Petroleum Equipment

Meters Petroleum Equipment

 

Meters of Petroleum Equipment measure the consistency of lubricating greases (Penetrometer) or determining their heat value which do not contain water, coal, paraffin and other combustible substance (Oxygen Bomb Calorimeter) or can trace low levels of free, emulsified and dissolved (Coulometric Karl Fischer Titrator)

 
(6) items
Compare Selected (0)
Go
Series : 300
Measurement range : 0 penetration~600 penetrations0 penetration~600 penetrations14400 J/K~14500 J/K14000 J/K~15000 J/K20 MPaMicroprocessor controlled titration
Penetrometer BPTL-301

Penetrometer BPTL-301

  • Measurement range: 0 penetration~600 penetrations
  • Resolution: 0.1 penetration(0.01mm)
  • Timing range: 5s, 8s, 10s, 12s, 30s, 60 s, and the error is less than ±0.1 s
  • Temperature control accuracy: 25 ℃± 0.1 ℃
  • Constant temperature bath: hard glass chamber
Penetrometer (For Wax & With Constant Temperature Bath) BPTL-302

Penetrometer (For Wax & With Constant Temperature Bath) BPTL-302

  • Measurement range: 0 penetration~600 penetrations
  • Resolution: 0.1 penetration(0.01mm)
  • Timing range: 5s, 8s, 10s, 12s, 30s, 60 s, and the error is less than ±0.1 s
  • Temperature control accuracy: 25 ℃± 0.1 ℃
  • Constant temperature bath: hard glass chamber
Automatic Oxygen Bomb Calorimeter BPTL-303

Automatic Oxygen Bomb Calorimeter BPTL-303

  • Heat capacity: 14400 J/K~14500 J/K
  • Pressure endurance of oxygen bomb: 20 MPa
  • Temperature measurement range: 10 ℃~35 ℃
  • Repeatability: ≤0.2% (Grade C)
  • Resolution: 0.001 K
Oxygen Bomb Calorimeter BPTL-304

Oxygen Bomb Calorimeter BPTL-304

  • Heat capacity: 14000 J/K~15000 J/K
  • Pressure endurance of oxygen bomb: 20 MPa
  • Temperature measurement range: 15 ℃~28 ℃
  • Repeatability error: ≤0.2% (Grade C)
  • Resolution: 1.001 K
Automatic Oxygen Bomb Calorimeter BPTL-305

Automatic Oxygen Bomb Calorimeter BPTL-305

  • Pressure endurance of oxygen bomb: 20 MPa
  • Measuring temperature range: 5℃~40℃
  • Temperature resolution: 0.0001℃
  • RSD(Relative standard deviation): ≤0.1%
  • Test time period:main period: about 8mins
Coulometric Karl Fischer Titrator BPTL-306

Coulometric Karl Fischer Titrator BPTL-306

  • Titration method: Microprocessor controlled titration
  • Sensitive valve: 0.1ugH2O
  • Accuracy: 10ug - 1mgH2O is ±3ug,1mgH2O above, 0.3% (excluding injection error).
  • Electrolytic current output: 0-400MA automatic control
  • Display system: LCD color 7 inch large screen display