Tester Petroleum Equipment

Machine Petroleum Equipment Meters Petroleum Equipment Tester Petroleum Equipment Viscometer Petroleum Equipment
81 products
No products match the selected specifications. Clear one or more filters to see products.
Tester Petroleum Equipment
Water Content Tester
Power Supply: AC (220±10%) V, 50Hz
Total Power Consumption: ≤ 2200W
Heating Control: Continuously adjustable by a silicon knob, manual
Ambient Temperature: (15-35) °C
Tester Petroleum Equipment
Dropping Point Tester
Oil Bath: 600ml Beaker
Grease Cup: Chrome plated brass, inner diameter 9.92mm, oil dripping hole 2.8mm, cup height 12mm
Test Tube: Heat resistant borosilicate glass tube with edge, inner diameter 11.1mm to 12.7mm, with three grooves 19mm from bottom
Stirring Motor: 60 R/min
Tester Petroleum Equipment
Cleveland Open-cup Flash Point Tester
Ignition Source: Coal gas (or civil gas)
Nozzle Aperture: About 0.8 mm
Thermometer: (-6 ~ 400) °C. Scale is 2 °C
Ambient Temperature: (15 ~ 35) °C
Tester Petroleum Equipment
Distillation Tester
Distillation Flask: 125 ml
Water Bath Temperature Controlling Range: (ambient temp. +10) °C ~ 60°C
Water Bath Temperature Controlling Accuracy: ±0.5°C
Receiving Cylinder: 100 ml, scale division 1 ml
Tester Petroleum Equipment
Pensky-martens Closed-cup Flash Point Tester
Inner Diameter: 50.7 mm ~ 50.8 mm
Depth: 55.7 mm ~ 56.0 mm
The Scribed Line Depth Of Capacity Of Testing Oil: 33.9mm ~ 34.3mm
Capacity Of Testing Oil: About 70ml
Tester Petroleum Equipment
Crude Petroleum Water Content Tester
Distillation Flask: 1000 ml
Receiver: 5ml, graduation is 0.05 ml
Condenser: 400mm±5mm
Heater: heating mantle cap, 500Wx2, continuous adjustment
Tester Petroleum Equipment
Cleveland Open Cup Flash Point Tester
Applicable Standards: GB/T3536, ASTM D92, ISO2592
Heating Method: Sealed stove, imported heating wire
Temperature Adjusting Method: Imported solid regulator
Scanning Method: Automatic scanning and igniting
Tester Petroleum Equipment
Equilibrium Boiling Point Tester
Applicable Standards: ASTM D1120, SH/T0089
Heating Mode: electric heating-jacket
Refrigeration Mode: tap water circulation
Temperature Control Mode: solid state voltage regulator (SSVD)
Tester Petroleum Equipment
Kinematic Viscosity Tester
Capillary Viscometer Tubes: 6 pieces total; inner diameters: 0.6mm, 0.8mm, 1.0mm, 1.2mm, 1.5mm, 2.0mm
Temperature Control Range: Ambient to 100°C
Temperature Control Accuracy: ±0.1°C
Temperature Sensor: RTD, Pt100
Tester Petroleum Equipment
Mechanical Impurity Tester
Temperature Control Range For Water Bath: Room temperature ~ 90°C, adjustable
Bath Temperature Display: Digitally displayed by LED
Temperature Control Accuracy For Water Bath: ±1°C
Temperature Control Range For Funnel: Room temperature ~ 90°C, adjustable
Tester Petroleum Equipment
Ash Content Tester
Rated Temperature: 1000°C
Temperature Rising Time For Empty Furnace: ≤50 min
Power Consumption For Empty Furnace: ≤800W
Furnace Temperature Uniformity: ≤15°C
Tester Petroleum Equipment
Carbon Residue Tester
Test Furnace: One furnace with four holes
Heating Mode: Electric furnace
Temp Control Range: (0 ~ 520)°C
Temp Control Accuracy: ±5°C
Tester Petroleum Equipment
Density Tester
Capacity Of Cylinder: 500ml
Range: (Ambient +5) °C to 100°C
Accuracy: ±0.2°C
Sensor: Pt100
Tester Petroleum Equipment
Petroleum Products Color Tester
Light Source: 220 V, 100 W
Temperature: 2750±50 K
Observation Lens Composition: concave mirror and separated bar
Standard Color Dial: 26 pieces of Φ14 light holes
Tester Petroleum Equipment
Kinematic Viscosity Tester
Capillary Viscometer Tubes: 6 pieces in total; inner diameter for each: 0.6mm, 0.8mm, 1.0mm, 1.2mm, 1.5mm, 2.0mm
Temperature Control Range: Ambient to 100°C
Temperature Control Accuracy: ±0.1°C
Temperature Sensor: RTD, Pt100
Tester Petroleum Equipment
Distillation Tester
Distillation Flask: 125 ml
Receiving Cylinder: 100 ml, scale division 1 ml
Temperature Controller Range: (Ambient +10)°C ~ 60°C
Temperature Controller Accuracy: ±0.5°C
Tester Petroleum Equipment
Distillation Tester (low-temperature)
Distillation Flask: 125 ml
Receiving Cylinder: 100 ml, scale division 1 ml
Heating Power: ≤2300W
Electric Furnace Heating Power: 1300W
Tester Petroleum Equipment
Cleveland Open-cup Flash Point Tester
Ignition Source: Coal gas (or civil gas)
Flame Diameter: 3.2 mm ~ 4.8 mm
Temperature Range: 0 °C ~ 400 °C
Display Accuracy: 0.1 °C
Tester Petroleum Equipment
Pensky-martens Closed-cup Flash Point Tester
Heating Device: (1) The furnace is silicon carbide material. Power is 600W. (2) The heating power is adjustable from 0W to 600W
Heating Rate: Procedure A: (5~6)°C/min, Procedure B: (1~1.5)°C/min
Stirring Device: (1) Stirring motor: BYGH101 stepping motor. (2) Driving mode: flexible shaft. (3) Shaft size: 8mmx40mm
Stirring Rate: Procedure A: (90~120) rpm, Procedure B: (250±10) rpm
Tester Petroleum Equipment
Low Temperaturetester
Working Chamber: Two test baths in one chamber. The temperatures are the same.
Range: Ambient to -70°C
Accuracy: ±0.5°C
Refrigeration: New-type refrigeration compressor
Tester Petroleum Equipment
Aniline Point Tester
Temperature Range: Ambient to 200°C
Temperature Precision: ≤0.5°C
Heating Power: ≤2100W
Ambient Temperature: 15°C ~ 35°C
Tester Petroleum Equipment
Demulsibility Characteristics Tester
Timing Range: 1s~9min59s
Stirring Rate: (1500±15) r/min
Temperature Range: (Room temp.+5~99.9)°C
Temperature Control Accuracy: ±1°C
Tester Petroleum Equipment
Water Separability Tester
Applicable Standards: GB/T7305, ASTM D1401, ISO6614
Temperature Controlling Method: Imported PID digital display temperature controller
Temperature Controlling Accuracy: Ambient ~ 100°C ±0.1°C
Heating Method: Water bath
Tester Petroleum Equipment
Copper Strip Corrosion Tester
Sample Testing Positions: Four positions
Sample Quantity At One Test: 4 pieces ~ 12 pieces
Temperature Range: Ambient to 100°C, can be set at will
Temperature Control Accuracy: ±1°C
Tester Petroleum Equipment
Vapor Pressure Tester (reid Method)
Temperature Control Range Of Bath: (Room temp.~90)°C
Temperature Control Accuracy Of Bath: ±0.1°C
Accuracy Of Pressure Meter: 0.4% F·S
Ambient Temperature: 15°C ~ 35°C
Tester Petroleum Equipment
Distillation Tester (low-temperature)
Distillation Flask: 125 ml
Receiving Cylinder: 100 ml, scale division 1 ml
Thermometer: (-2~300)°C and (-2~400)°C, division value 1°C
Furnace Heating Power: 1300W x 2
Tester Petroleum Equipment
Foaming Characteristic Tester
Temperature Control Range For High Temperature Bath: (Room temp.~99.9)°C
Temperature Control Range For Low Temperature Bath: (5~99.9)°C
Temperature Control Accuracy: ±0.5°C
Air Flow Rate: (94±5) ml/min, adjustable
Tester Petroleum Equipment
Density And Specific Gravity Testing Equipment
Applicable Standards: GB/T1884 ISO3675 ASTM D1298
Working Unit: double units
Refrigeration Method: Air compressor
Temperature Controlling Method: Imported digital PID
Tester Petroleum Equipment
Engine Coolant Foaming Tendency Analyzer
Applicable Standards: ASTM D1881, SH/T0066
Temperature Controlling Range: 88±1°C
Velocity Of Flow: 1000±25ml/min
Working Units: 2 holes
Tester Petroleum Equipment
Kinematic Viscosity Tester
Capillary Viscometer Tubes: 6 pieces total; inner diameters: 0.6mm, 0.8mm, 1.0mm, 1.2mm, 1.5mm, 2.0mm
Amount Of Capillary Viscometer Tubes: 4 capillary viscometers
Bath Capacity: 20L
Working Condition: 15°C ~ 35°C
Tester Petroleum Equipment
Vacuum Distillation Tester
Capacity Of Buffer Vessel: 1000 ml
Heating Power Distillation Flask: 1300W
Heating Power Receiver: 350W
Heating Furnace Of Distillation Flask: (0 ~ 1300)W, continuously adjustable
Tester Petroleum Equipment
Existent Gum Tester
Sample Positions: 5 positions
Dimension Of Sample Position: φ51mmx70mm
Working Temperature: (160 ~ 165)°C
Dimension Of Evaporation Bath: φ260mmx130mm
Tester Petroleum Equipment
Copper Strip Test Bath Corrosiveness Testing Equipment
Applicable Standards: GB/T5096, ASTM D130, ISO3735, DIN51789
Temperature Controlling Method: imported PID digital display temperature controller
Temperature Controlling Accuracy: room temperature~150±0.1°C
Heating Method: oil bath
Tester Petroleum Equipment
Automatic Demulsibility Characteristics Tester
Testing Hole: 4 sample
Stirring Rate: (1500±15) r/min
Stirring Time: (0~99) min
Timing: (0~99) h
Tester Petroleum Equipment
Hydraulic Oil Thermal Stability Tester
Applicable Standard: SH/T 0209
Temperature Control Method: Imported PID Digital Temperature Controller
Temperature Control Accuracy: Room temperature to 200°C ± 0.1°C
Heating Method: Metal Bath Heating
Tester Petroleum Equipment
Engine Coolants Corrosion Tester
Applicable Standards: ASTM D1384, SH/T0085
Heating Mode: electric heating pipe
Temperature Control Mode: digital PID temperature controller
Pressure Display: Pressure gauge
Tester Petroleum Equipment
Automatic Coc Flash Point Tester
Mode: Electric ignition
Gas Flame Diameter: 3.2 mm ~ 4.8 mm
Range: Ambient to 400°C
Repeatability: ≤ 8°C (Flash Point)
Tester Petroleum Equipment
Automatic Cleveland Open Cup Flash Point Tester, Cleveland Open-cup Flash Point Tester
Ignition Mode: Electric ignition
Diameter Of Igniter: 0.7 mm ~ 0.8 mm
Initial Heating: 14 ~ 17 °C/min
Heating Rate: It is (5-6)°C/min after reaching the preset flash point 20°C
Tester Petroleum Equipment
Vacuum Distillation Tester
Heating Furnace Of Distillation Flask: (0 ~ 1300)W, adjustable
Setting Range Of Vacuum Residual Pressure: (2 ~ 50) mmHg
Accuracy Of Vacuum Residual Pressure: ±0.5 mmHg
Heating Power Of Receiver: 350W, automatically controlled
Tester Petroleum Equipment
Lubricating Oil Air Release Value Tester
Applicable Standard: SH/T0308, ASTM D3427, DIN51585, NFT60151, IP135
Power Supply: AC 220V ±10%, 50Hz ±5%
Heating Mode: Electric bar
Temperature Controlling Range: Ambient ~ 80 ±1°C; if using silicon oil, it can reach higher temperature
Tester Petroleum Equipment
Rust Prevention Tester
Applicable Standards: ASTM D665, GB/T11143
Temperature Control Method: Imported digital PID temperature controller
Temperature Control Accuracy: 60 ± 0.1°C
Heating Method: Electrical heating rod
Tester Petroleum Equipment
Multifunctional Low Temperature Tester
Chamber I: -17°C ~ 0°C, accuracy ±0.5°C, temperatures in two cold baths are the same.
Chamber Ii: -30°C
Chamber Iii: -51°C ~ -34°C, accuracy ±0.5°C, temperatures in two cold baths are the same.
Chamber Iv: -70°C
Tester Petroleum Equipment
Foam Tendency Bath Instrument With Cooler
Applicable Standards: GB/T12579, ASTM D892, ISO6247, NFT60129
Working Unit: 4 units
Heating Method: oil bath
Temperature Controlling Method: Imported digital PID
Tester Petroleum Equipment
Distillate Fuel Oils Oxidation Stability Tester
Sample Quantity: It can determine 6 samples at a time
Temperature Measuring Component: Thermal resistance
Temperature Control Mode: Automatically controlled by digital temperature controller
Temperature Control Range: Ambient to 100°C
Tester Petroleum Equipment
Hydrolytic Stability Tester
Applicable Standards: SH/T0301, ASTM D2619
Heating Mode: Stainless steel electrical heating tube
Heating Power: 1.2KW
Temperature Control Range: Ambient~93°C
Tester Petroleum Equipment
Water Washout Properties Tester
Applicable Standard: SH/T0109, ASTM D1264
Temperature Control Accuracy: ±0.1°C
Temperature Control Range: Ambient~100°C
Working Temperature: 37.8 ± 0.1°C and 79 ± 0.1°C
Tester Petroleum Equipment
Automatic Pmcc Flash Point Tester
Heating Rate Procedure A: (5 ~ 6) °C/min
Heating Rate Procedure B: (1 ~ 1.5) °C/min
Heating Rate Procedure C: (3.0 ± 0.5) °C/min
Stirring Rate Procedure A And C: (90 ~ 120) rpm
Tester Petroleum Equipment
High Temperature Foaming Apparatus
Applicable Standards: ASTM D6082, SH/T0722
Temperature Control Method: Imported PID digital temperature controller
Temperature Control Accuracy: 150 ± 0.1°C
Heating Method: Liquid bath heating
Tester Petroleum Equipment
Oxidation Stability Tester
Applicable Standards: ASTM D2274, ISO12205, SH/T0175
Temperature Control Method: Digital PID temperature controller
Circulating Method: Magnetic pump circulation
Temperature Control Range: 20-95°C ±0.2°C
Tester Petroleum Equipment
Oil Oxidation Stability Tester
Temperature Control Point For Test Bath: 140°C, 150°C
Temperature Control Accuracy: ±0.1°C
Range For Pressure Sensor: (0~1.6) MPa
Pressure Accuracy: ±0.5%
Tester Petroleum Equipment
Automatic Vapor Pressure Tester (reid Method)
Test Bomb: Can do 3 bomb tests at the same time
Water Bath Temperature: 37.8°C
Pressure Range: (0 ~ 200) kPa or (0 ~ 29) psi
Temperature Control Accuracy: ±0.1°C
Tester Petroleum Equipment
Automatic Freezing Point Tester
Freezing Point Range: -54°C ~ 2°C
Working Bath: stainless steel, double vacuum glass observing window
Cold Bath Measurement Temperature: -70°C ~ 30°C
Temperature Controlling Accuracy: ±0.1°C
Tester Petroleum Equipment
Liquid Petroleum Product Hydrocarbon Tester
Air Supply: Nitrogen cylinder (or air compressor, compressed air bottle)
Pressure Regulating Range Of Reducing Valve: (0~400) kPa
Electric Agitator: Independently controlled for each way
Ultraviolet Light Source Pipe: 1220mm in length, wavelength is 365mm±5nm
Tester Petroleum Equipment
Multifunctional Pour Point Test Instrument
Applicable Standards: GB/T2525, GB/T510, ASTM D97
Temperature Controlling Method: imported PID digital display temperature controller
Temperature Controlling Accuracy: -70±0.1°C
Refrigeration Method: imported double compressor
Tester Petroleum Equipment
Fully Automatic Cleveland Open Flash Point Meter
Applicable Standards: GB/T3536, ISO2592, ASTM D92
Display Mode: LCD
Display Contents: Controlling temperature and expected set flash pointFault promptEvery model specifications and atmosphere setting
Measuring Range: Ambient ~ 400°C
Tester Petroleum Equipment
Carbon Residue Tester (micromethod)
Temperature Of Coke Chamber: 500°C
Temperature Control Accuracy: ±2°C
Heating Power: 1200W
Ambient Temperature: 5°C ~ 35°C
Tester Petroleum Equipment
Closed Cup Flash Point Tester
Applicable Standards: GB/T261, ISO2719, ASTM D93, DIN51751
Display Mode: LCD big screen in English
Display Content: Control temperature and set temperature of expected flash point; Fault warning; Each simulated parameters and pressure setting
Measuring Range: 40~370°C
Tester Petroleum Equipment
Automatic Vapor Pressure Tester
Power Supply: AC(220±10%)V, 50Hz
Maximum Power Consumption: ≤1700W
Test Bomb: Can do 3 bomb tests at the same time
Water Bath Temperature: 37.8°C
Tester Petroleum Equipment
Automatic Gasoline Oxidation Stability Tester (induction Period Method)
Heating Tube Power: ≤1000W, The actual heating power is automatically controlled by the computer
Measuring Range Of Oxygen Bomb Pressure Transmitter: (0 ~ 1600) kPa, accuracy: ±2%
Temperature Control Point Of Metal Bath: 100.0°C ± 0.5°C
Thermometer: Mercury-in-glass thermometer, can correct coefficient as need
Tester Petroleum Equipment
Rapid Low Temperature Closed Cup Flash Point Tester
Flash Point Measuring Range: -30°C ~ +100°C
Precision Of Determination: Meets standard GB/T 5208
Temperature Resolution: ±0.1°C
Igniting Device: Electric igniting gun
Tester Petroleum Equipment
Gasoline Oxidation Stability Tester
Power Supply: AC (220±10%) V, 50Hz
Total Power Consumption: 1400W
Measuring Range Of Oxygen Bomb Pressure Transmitter: (0~1600) kPa, Accuracy: ±2%
Temperature Control Point Of Metal Bath: 100.0°C ±0.1°C
Tester Petroleum Equipment
Rapid Low Temperature Closed Cup Flash Point Tester
Flash Point Measuring Range: -10°C ~ +100°C
Temperature Resolution: ± 0.1°C
Igniting Device: Electric igniting gun
Cooling Mode: Semiconductor (with cold water cycle at external connection)
Tester Petroleum Equipment
Thermal Stability Test Equipment
Applicable Standard: ASTM D6743, DIN 51528, SH/T0680, GB/T23971, GB/T23800
Temperature Control Method: imported PID digital temperature controller
Temperature Control Range: RT~400°C
Temperature Control Accuracy: ± 0.1°C
Tester Petroleum Equipment
Automatic Cfpp Tester
Temperature Range: -70~40°C
Resolution: 0.1°C
Pressure Measuring Range: 0~200.0 KPa; resolution 1Pa
Filter: 363 mesh stainless steel wire mesh
Tester Petroleum Equipment
Total Acid Number Tester
Burette Volume: 10ml
Burette Precision: ±0.1%F•S
Burette Dripping Time: (60±20)S(F·S)
Potential Measurement Range: (0~±1800.0)mV
Tester Petroleum Equipment
Evaporating Loss Tester
Applicable Standards: SH/T 0059; ASTM D5800 B
Temperature Range: Ambient ~ 300°C
Temperature Setting: Resolution accuracy ±0.1°C; temperature accuracy ±0.5°C
Heating Unit: Environmentally friendly lightweight heating unit
Tester Petroleum Equipment
Vacuum Distillation Tester
Temperature Control Range Of Condensate Circulating Water: Ambient+5°C (Min. 30°C) ~ 80°C±3°C; adjustable
Working Mode Of Condensate Trap: Semiconductor refrigeration
Minimum Temperature: ≤ - 40 °C
Absolute Pressure Setting: 2 mmhg, 5 mmhg, 10 mmhg, 20 mmhg, 50 mmhg
Tester Petroleum Equipment
X-ray Fluorescence Sulfurin- Oil Analyzer
Oil Sample Quantity: 6 ml
Powder Sample Quantity: 3 g
Detection Limit: 50 ppm
Measuring Range: 0.005% ~ 5%
Tester Petroleum Equipment
Automatic Engine Oils Apparent Viscosity Tester
Viscosity Measurement Range: 1500mPa·s ~27000mPa·s
Cold Bath Temperature Control Range: Ambient ~ -60°C
Cold Bath Temperature Control Accuracy: ±0.5°C
Stator Temperature Control Accuracy: ±0.05°C
Tester Petroleum Equipment
Automatic Lubricating Oils Oxidation Stability Tester
Test Sample: Two-bomb design, can do two samples at one time. Convenient to do parallel test.
Rotation Speed: (100±1)r/min
Included Angle Between Oxygen Bomb And Water Level: 30°
Range For Pressure Sensor: (0 ~ 1.6)MPa
Tester Petroleum Equipment
Lubricating Greases Corrosion-preventive Properties Tester
Applicable Standards: ASTM D6138
Rotating Method: AC motor drive
Rotating Speed: 80~85r/min
Timing Method: Digital timer
Tester Petroleum Equipment
Fully Automatic Quenching Medium Cooling Performance Tester
Applicable Standards: SH/T 0220, JIS K2242 (or optionally ISO 9950)
Heating Method: Electric heating wire
Temperature Control Range: 80 ± 2°C, 810 ± 2°C
Control Method: Digital Display PID Automatic Temperature Control
Tester Petroleum Equipment
Low-temperature Torque Tester
Applicable Standards: SH/T0338, ASTM D1478
Refrigeration Method: Imported French Tecumseh compressor unit
Temperature Controlling Range: ambient-70°C
Temperature Control: Digital timer
Tester Petroleum Equipment
Automatic Distillation Tester
Temperature Range Of Bath: 0 ~ 60°C
Temperature Control Precision Of Bath: ±0.5°C
Temperature Range Of Receiving Chamber: 0 ~ 60°C
Temperature Control Precision Of Receiving Chamber: ±1°C
Tester Petroleum Equipment
Automatic Freezing Point Tester
Applicable Standard: SH/T0090, ASTM D1177, NFT 78102
Temperature Control Method: Imported PID temperature controller
Temperature Control Range: -70 ± 0.1°C
Refrigerator System: Imported dual air compressors
Tester Petroleum Equipment
Ultraviolet Fluorescence Sulfurin-oil Analyzer
Sample Injection Quantity: Solid: 1-20 mg; Liquid: 5-20 μL; Gas: 1-5 mL
Determination Method: Ultraviolet fluorescence method (S)
Measuring Range: 5 ppm ~ 5000 ppm (High concentration should be diluted, low concentration gas sample is up to 0.1 ppm)
Temperature Range: Ambient to 1150°C
Tester Petroleum Equipment
Fully Automatic Distilled Oil Analyzer
Applicable Standards: GB/T6536; ASTM D 86, ISO 3405;
Measuring Temperature: Ambient~+400°C
Temperature Controlling Accuracy: +/- 0.1°C
Volume Accuracy: +/- 0.1 ml
Tester Petroleum Equipment
Oil Oxidation Stability Tester
Temp Controlling: Import PID temp.controller
Flow Range: 8~12L/h±10%
Measuring Range: 0~800 μS/cm
Resolution: 0.1μS/cm
Tester Petroleum Equipment
Apparent Viscosity Tester
Applicable Standard: SH/T0703, ASTM D5481
Heating Method: Electric heating rod
Test Temperature: Ambient to 150°C
Temperature Control Accuracy: ±0.1°C
Tester Petroleum Equipment
Scanning Brookfield Gelation Index Test Instrument
Power Supply: AC(220±10%)V, 50Hz
Refrigeration: Semiconductor
Temperature Control Range: Room temperature ~ -40°C (-70°C is customized)
Temperature Control Accuracy: ±0.1°C
Tester Petroleum Equipment
Shear Stability Tester
Applicable Standards: SH/T0103, ASTM D3945
Timing Method: Automatic stroke timer
Refrigeration Method: Air compressor
Temperature Control Range: 35±0.2°C