Conductivity Meter
Conductivity meter is an instrument that measures the amount of electric conductivity or current in a solution. The conductance can be measured by applying an alternating electrical current to the two electrodes present in the solution, after which the cations move to the negative electrode and the anions move to the positive electrode. This movement ultimately leads the solution to be conductive.
Operating Manuals
(7) items
Go
Series : 300
Conductivity: Range : 0.00 μS/cm to 100 mS/cm0.00 μS/cm to 200 mS/cm0.000 μS/cm to 1000 mS/cm0.000 μS/cm to 3000 mS/cm0.00 μS/cm to 100 mS/cm0.000 μS/cm to 500 mS/cm0.000 μS/cm to 3000 mS/cm
Conductivity Meter BMET-301
- Conductivity: Range: 0.00 μS/cm to 100 mS/cm
- Conductivity: Resolution: 0.01 μS/cm minimum; changed with range
- Conductivity: Accuracy: ± 1.5 % FS
- Conductivity: Reference Temperature: 25 °C
- Measurement: Reading Mode: Continuous
Conductivity Meter BMET-302
- Conductivity: Range: 0.00 μS/cm to 200 mS/cm
- Conductivity: Resolution: 1.01 μS/cm minimum; changed with range
- Conductivity: Accuracy: ± 1.0 % FS
- Conductivity: Reference Temperature: 25 °C
- Conductivity: Standard Recognition: 84 μS/cm, 1413 μS/cm; 12.88 mS/cm
Conductivity Meter BMET-303
- Conductivity: Range: 0.000 μS/cm to 1000 mS/cm
- Conductivity: Resolution: 0.001 μS/cm minimum; changed with range
- Conductivity: Accuracy: ± 1.0 % FS
- Conductivity: Reference Temperature: 20, 25 °C
- Conductivity: Standard Recognition: 85 μS/cm, 1413 μS/cm; 12.88 mS/cm
Conductivity Meter BMET-304
- Conductivity: Range: 0.000 μS/cm to 3000 mS/cm
- Conductivity: Resolution: 0.001 μS/cm minimum; changed with range
- Conductivity: Accuracy: ± 0.5 % FS
- Conductivity: Reference Temperature: 5, 10, 15, 18, 20, 25 °C
- Conductivity: Calibration Points: Up to 5
Conductivity Meter BMET-305
- Conductivity: Range: 0.00 μS/cm to 100 mS/cm
- Conductivity: Resolution: 0.01 μS/cm minimum; changed with range
- Conductivity: Accuracy: ± 1.0 % FS
- Conductivity: Reference Temperature: 25 °C
- Measurement: Reading Mode: Continuous
Conductivity Meter BMET-306
- Conductivity: Range: 0.000 μS/cm to 500 mS/cm
- Conductivity: Resolution: 0.001 μS/cm minimum; changed with range
- Conductivity: Accuracy: ± 1.0 % FS
- Conductivity: Reference Temperature: 20, 25 °C
- Conductivity: Calibration Points: Up to 3
Conductivity Meter BMET-307
- Conductivity: Range: 0.000 μS/cm to 3000 mS/cm
- Conductivity: Resolution: 1.001 μS/cm minimum; changed with range
- Conductivity: Accuracy: ± 0.5 % FS
- Conductivity: Reference Temperature: 5, 10, 15, 18, 20, 25 °C
- Conductivity: Calibration Points: Up to 5