Nano Spectrophotometer
Biolab Nano spectrophotometer is a compact, micro volume UV Visible Spectrophotometer with enhanced sensitivity that can detect samples at 3ng/µl. It gives you fast measurement typically less than 5sec\sample and provides rapid and reproducible results without prior dilution. With robust instrumentation and ease of use, our product is most preferred for quick analysis in labs.
Operating Manuals
(11) items
Go
Series : 100
Minimum Sample Size : 1-2.0 μl 0.5-2.0 µl 0.5-2.0 µl 0.5-2.0 µl
Nano Spectrophotometer BSNA-101
- Minimum Sample Size: 1-2.0 μl
- Wavelength Range: 260nm, 280nm
- Absorbance Range: 0.02-80A
- Absorbance Accuracy: 1% (7.332Abs at 260nm)
- Absorbance Precision: 0.005Abs
Nano Spectrophotometer BSNA-102
- Minimum Sample Size: 0.5-2.0 µl
- Wavelength Range: 200-800 nm
- Wavelength Accuracy: 1 nm
- Spectral Resolution: ≤ 3 nm (FWHM at Hg 546 nm)
- Absorbance Range: 0.02-90A
Nano Spectrophotometer BSNA-103
- Minimum Sample Size: 0.5-2.0 µl
- Wavelength Range: 200-800 nm
- Wavelength Accuracy: 1 nm
- Spectral Resolution: ≤ 3 nm (FWHM at Hg 546 nm)
- Absorbance Range: 0.02-100A
Nano Spectrophotometer BSNA-104
- Minimum Sample Size: 0.5-2.0 µl
- Wavelength Range: 200-800 nm
- Wavelength Accuracy: 1 nm
- Spectral Resolution: ≤ 3 nm (FWHM at Hg 546 nm)
- Absorbance Range: 0.02-100A
Series : 200
Minimum Sample Size : 0.3-2.0 µl 0.3-2.0 µl 0.3-2.0 µl 0.3-2.0 µl
Nano Spectrophotometer BSNA-201
- Minimum Sample Size: 0.3-2.0 µl
- Wavelength Range: 260 nm, 230 nm and 280 nm
- Wavelength Accuracy: Fixed wavelength point
- Wavelength Reproducibility: <±0.2 nm
- Spectral Bandwidth: ≤5 nm
Nano Spectrophotometer BSNA-202
- Minimum Sample Size: 0.3-2.0 µl
- Wavelength Range: 200-850 nm
- Wavelength Accuracy: ±1 nm
- Wavelength Reproducibility: <±0.2 nm
- Spectral Bandwidth: ≤5 nm
Nano Spectrophotometer BSNA-203
- Minimum Sample Size: 0.3-2.0 µl
- Wavelength Range: 200-850 nm
- Wavelength Accuracy: ±1 nm
- Wavelength Reproducibility: <±0.2 nm
- Spectral Bandwidth: ≤5 nm
Nano Spectrophotometer BSNA-204
- Minimum Sample Size: 0.3-2.0 µl
- Wavelength Range: 190-850 nm
- Wavelength Accuracy: ±1 nm
- Spectral Resolution: 2 nm (FWHM at Hg 546)
- Temperature Range: 4°C-42°C
Series : 300
Test sample capacity : 2.0-2000 ng/μl (dsDNA) Measurement Sample Size:2.0 μl
Nano Spectrophotometer BSNA-301
- Minimum Sample Size: 2.0-2000 ng/μl (dsDNA) Measurement Sample Size:2.0 μl
- Wavelength Range: OD230nm, OD260nm, OD280nm, OD320nm
- Measurement Data output: 1. Sample concentration (ng/ μl) 2. OD230nm/OD260nm, OD280nm/OD320nm
- Absorbance Range: 0.04~40 ( 10 mm )
- Path Length: ~0.5 mm
Series : 400
Test sample capacity : 0.5~2 μl0.5~2 μl
Nano Spectrophotometer BSNA-401
- Test sample capacity: 0.5~2 μl
- Detection concentration range: 2~15000 ng/μl(dsDNA)
- Measurement Time: About 5 s
- Light absorption accuracy: 0.002 Abs (1mm)
- Absorbance accuracy: 1% (0.76 Abs at 256 nm)
Nano Spectrophotometer BSNA-402
- Test sample capacity: 0.5~2 μl
- Cuvette specifications: 12.5mm(L)x12.5mm(W)x45mm(H) Stirring speed of cuvette
- Measurement Time: About 5 s
- Cuvette optical path length: 10, 5, 2, 1mm
- Cuvette beam height: 6mm