Staining is a process in which the tissue sample is exposed to colored dye which penetrates specific cell components to make the component of interest more visible under the microscope. Slide stainer stain prepared slides of processed tissue to enhance the contrast within a specimen for microscopic study. The operator to be heat the slides loads it into the solution reservoir and depending on requirement it is stained once or twice then rinsed and dried.

 
(7) items
Compare Selected (0)
Go
Series : 400
Specimen slide throughput : At least 200 specimen slides per hour (depend on the selected program)7 – inch color touch screen operation16 sets can be programmed arbitrarilyprovides starting protection48Single stainingRT + 5 ℃ ~ 100 ℃
Automatic Slide Stainer BHTP-401

Automatic Slide Stainer BHTP-401

  • Specimen slide throughput: At least 200 specimen slides per hour (depend on the selected program)
  • Loading capacity: 3 slides rack
  • Slide rack capacity: 30 specimen slides
  • Total number of stations: 26
  • Number reagent stations: 18
Automatic Slide Stainer BHTP-402

Automatic Slide Stainer BHTP-402

  • Screen: 7 – inch color touch screen operation
  • Cylinder design reagents: 18
  • Dye cylinder volume: 1000 ml
  • Rated voltage: 220 v ± 10 % AC
  • Power frequency: 50 ± 1 Hz
Slide Stainer BHTP-403

Slide Stainer BHTP-403

  • Programs: 16 sets can be programmed arbitrarily
  • Volume of a single cylinder: 1000 ml
  • Loading capacity of a single cylinder: 62 pieces each time
  • Single-cylinder processing time: 0~99 min 99 s
  • Number of shaking time of the cylinder: can be adjusted arbitrarily
Slide Stainer BHTP-404

Slide Stainer BHTP-404

  • First cylinder: provides starting protection
  • Cleaning cylinder: 5
  • Hematoxylin cylinder: 1
  • Differentiation cylinder: 1
  • Eosin cylinder: 1
Immuno Autostainer BHTP-405

Immuno Autostainer BHTP-405

  • Slides Capacity: 48
  • Reagents Capacity: 64
  • Minimum dropping reagent: 50 μl
  • Dropping reagent increment: 50 μl, 100 μl, 150 μl, 200 μl
  • Maximal output power: ≤ 350 VA
Fully Immuno Autosatiner BHTP-406

Fully Immuno Autosatiner BHTP-406

  • Staining mode: Single staining
  • Reagent consumption: General use 120 μl
  • Reagent positions: 36 (29 for antibody reagent bottles, 7 for detection system bottles)
  • Self-calibration: When opening the instrument, it will run self-calibration automatically
  • Mixing station: 6 positions
Hybridizer BHTP-407

Hybridizer BHTP-407

  • Temperature control range: RT + 5 ℃ ~ 100 ℃
  • Temperature set range: 0 ℃ ~ 100 ℃
  • Accuracy of temperature: ≤ ± 1 ℃
  • Uniformity temperature: ≤ ± 1 ℃
  • Heating time: ≤ 2 min (37 ℃ to 95 ℃)