(7) items
Go
Premium
Editable programs : 16 sets, programmable arbitrarily
Processing volume per cylinder : 1000 ml
Loading capacity : 65 pieces each time
Single-cylinder processing time : 0~99 min 99 sec
Number of shaking adjustments : Adjustable
Staining System BHM1O1 (BHTP-403)
Slide StainerEditable programs : 16 sets, programmable arbitrarily
Processing volume per cylinder : 1000 ml
Loading capacity : 65 pieces each time
Single-cylinder processing time : 0~99 min 99 sec
Number of shaking adjustments : Adjustable
Premium
Temperature control range : RT+5 °C ~ 100 °C
Temperature set range : 0 °C ~ 100 °C
Accuracy of temperature : ≤ ±1 °C
Temperature stability : ≤ ±1 °C
Heating time : ≤2 min (37 °C to 95 °C)
Staining System BHM1S1 (BHTP-407)
HybridizerTemperature control range : RT+5 °C ~ 100 °C
Temperature set range : 0 °C ~ 100 °C
Accuracy of temperature : ≤ ±1 °C
Temperature stability : ≤ ±1 °C
Heating time : ≤2 min (37 °C to 95 °C)
Elite
Rated voltage : 220V ±10% AC
Power frequency : 50 ±1 Hz
Rated power : ≤500 W
Reagent tanks : 18 cylinders
Tank volume : 1000 ml
Staining System BHM1N1 (BHTP-402)
Tissue Slide StainerRated voltage : 220V ±10% AC
Power frequency : 50 ±1 Hz
Rated power : ≤500 W
Reagent tanks : 18 cylinders
Tank volume : 1000 ml
Elite
Number of liquid cylinders : 15
First cylinder function : Automatic start-up saving cylinder
Number of cleaning tanks : 3
Number of hematoxylin tanks : 1 (water bath heating)
Number of differentiation tanks : 1
Staining System BHM1P1
Slide StainerNumber of liquid cylinders : 15
First cylinder function : Automatic start-up saving cylinder
Number of cleaning tanks : 3
Number of hematoxylin tanks : 1 (water bath heating)
Number of differentiation tanks : 1
Elite
Specimen slide throughput : At least 200 specimen slides per hour (depend on program)
Loading capacity : 3-5 slides rack
Slide rack capacity : 30 specimen slides
Total number of stations : 26
Number of reagent stations : 18
Staining System BHM1M1 (BHTP-401)
Automatic Slide StainerSpecimen slide throughput : At least 200 specimen slides per hour (depend on program)
Loading capacity : 3-5 slides rack
Slide rack capacity : 30 specimen slides
Total number of stations : 26
Number of reagent stations : 18
Elite
Slides Capacity : 48
Reagents Capacity : 64
Minimum dropping reagent : 50 μl
Dropping reagent increment : 50 μl, 100 μl, 150 μl, 200 μl
Maximal output power : ≤350 VA
Staining System BHM1Q1 (BHTP-405)
Immuno Auto StainerSlides Capacity : 48
Reagents Capacity : 64
Minimum dropping reagent : 50 μl
Dropping reagent increment : 50 μl, 100 μl, 150 μl, 200 μl
Maximal output power : ≤350 VA
Elite
Slides Capacity : 48 pcs
Reagents Capacity : 48 pcs
Reagent Usage : 50-600 μl
Cross-contamination : <10^-6
Operation Temperature : Ambient
Staining System BHM1R1 (BHTP-406)
Immuno Auto StainerSlides Capacity : 48 pcs
Reagents Capacity : 48 pcs
Reagent Usage : 50-600 μl
Cross-contamination : <10^-6
Operation Temperature : Ambient