Section thickness Range : 0-60 μm
Section thickness setting : 0-2 um in 0.5 um -incrementsa) 2-10um in 1 um-incrementsb) 10-20 um in 2 um-incrementsc) 20-60um in 5 um-increments
Specimen Horizontal stroke : 20 mm
Specimen Vertical stroke : 50 mm
Slip precision : ±5%
Microtome BHM1I1 (BHTP-203)
Rotary MicrotomeSection thickness Range : 0-60 μm
Section thickness setting : 0-2 um in 0.5 um -incrementsa) 2-10um in 1 um-incrementsb) 10-20 um in 2 um-incrementsc) 20-60um in 5 um-increments
Specimen Horizontal stroke : 20 mm
Specimen Vertical stroke : 50 mm
Slip precision : ±5%
Premium
Section thickness Range : 0.5 μm - 100 μm (best slicing: 3-5 μm)
Section thickness setting : 0.5~5μm,in 0.5μm incrementa) 5~20μm,in 1μm incrementsb) 20~60μm,in 5μm incrementsc) 60~100μm,in 10μm increments
Trimming thickness Range : 1-600 μm
Trimming thickness setting : 1-10 μm step 1 μm1~10μm,in 1μm increment ;a) 10~20μm,in 2μm incrementsb) 20~50μm,in 5μm increments;c) 50~100μm,in 10μm increments;d) 100~600μm,in 50μm increments
Specimen Horizontal stroke : 20 mm
Microtome BHM1H1 (BHTP-202)
Semi- Automatic MicrotomeSection thickness Range : 0.5 μm - 100 μm (best slicing: 3-5 μm)
Section thickness setting : 0.5~5μm,in 0.5μm incrementa) 5~20μm,in 1μm incrementsb) 20~60μm,in 5μm incrementsc) 60~100μm,in 10μm increments
Trimming thickness Range : 1-600 μm
Trimming thickness setting : 1-10 μm step 1 μm1~10μm,in 1μm increment ;a) 10~20μm,in 2μm incrementsb) 20~50μm,in 5μm increments;c) 50~100μm,in 10μm increments;d) 100~600μm,in 50μm increments
Specimen Horizontal stroke : 20 mm
Elite
Section thickness Range : 0.5 μm - 100 μm (best slicing: 3-5 μm)
Section thickness setting : 0.5~5μm,in 0.5μm incrementa) 5~20μm,in 1μm incrementsb) 20~60μm,in 5μm incrementsc) 60~100μm,in 10μm increments
Trimming thickness Range : 1-600 μm
Trimming thickness setting : 1~10μm,in 1μm increment ;a) 10~20μm,in 2μm incrementsb) 20~50μm,in 5μm increments;c) 50~100μm,in 10μm increments;d) 100~600μm,in 50μm increments;
Specimen Retraction : 10-150 μm adjustable (can be closed), step 1 μm
Microtome BHM1G1 (BHTP-201)
Fully Automatic MicrotomeSection thickness Range : 0.5 μm - 100 μm (best slicing: 3-5 μm)
Section thickness setting : 0.5~5μm,in 0.5μm incrementa) 5~20μm,in 1μm incrementsb) 20~60μm,in 5μm incrementsc) 60~100μm,in 10μm increments
Trimming thickness Range : 1-600 μm
Trimming thickness setting : 1~10μm,in 1μm increment ;a) 10~20μm,in 2μm incrementsb) 20~50μm,in 5μm increments;c) 50~100μm,in 10μm increments;d) 100~600μm,in 50μm increments;
Specimen Retraction : 10-150 μm adjustable (can be closed), step 1 μm