Lifting method : One-click, AutomaticAutomatic stroke timerFully automaticAutomatic when temperature is too highDry heating,avoiding toxicity produced by traditional wood's metal heat conductionAutomatic41 – 4Upto 0.01 s6, simultaneously924 groups sample expandable to 8 groupsMain unit and gas source controller8 groups sample simultaneouslyMain unit and gas source controllerReleased and lifted automaticallyMain unit and gas source controller2 sample simultaneouslyTwo, temperature controlled separatelyIR heating furnace no radiation, fast temperature rising speedStatic and Dynamic3, can be extended to 4-6 unitsfixed speed 600 rpmCan reach to -75 °C4 sample simultaneouslyAutomatically fill in or discharge oxygen and detect leakageSCM controlling system can automatically complete raising temperature, cooling, tempeature recording,printing etcCoal gas (or civil gas)Coal gas (or civil gas)Electric ignitionElectric ignition50.7 mm~50.8 mm(1) The furnace is silicon carbide material. Power is 600W. (2) The heating power is adjustable from 0 W to 600W(5~6) ℃/min-30℃~+50℃-10℃~+100℃Can be continuously adjusted by a silicon knob, manual.6 pieces in total, inner diameter for each:0.6mm, 0.8mm, 1.0mm, 1.2mm, 1.5mm, 2.0mm6 pieces in total, inner diameter for each:0.6mm, 0.8mm, 1.0mm, 1.2mm, 1.5mm, 2.0mm6 pieces in total. The inner diameter for each: 0.6mm, 0.8mm, 1.0mm, 1.2mm, 1.5mm, 2.0mm125 ml125 ml125 ml125 ml(0~60)℃1000 ml(0~1300)W, adjustableAmbient+5℃(Min. 30℃)~80℃±3℃; adjustable500mlTwo test baths in one chamber. The temperatures are the same.-17℃~0℃,accuracy±0.5℃, temperatures in two cold baths are the same.-54℃~2℃Four positionsOne furnace with four holes500℃1s∼9min59s4 sample(Room temp.~99.9)℃5 positions(Room temp.~90)℃Can do 3 bomb tests at the same time≤1000W, The actual heating power is automatically controlled by the computerIt can determine 6 samples at a timeTwo-bomb design, can do two samples at one time. Convenient to do parallel test.Nitrogen cylinder (or air compressor,compressed air bottle)600ml Beaker6mlRoom temperature~90 ℃, adjustable1000℃220 V, 100 WAmbient to 200℃1000 ml10ml1500mPa•s ~27000mPa•s
- Lifting method: One-click, Automatic
- Viscosity and Gelation curve: Automatic scan
- Gelation index and Temperature analysis: Automatic
- Temperature: Multi-point calibration
- Timing method: Automatic stroke timer
- Temperature control range: 30 – 35 °C
- Rotation speed: 925 ± 25 r/min
- Power: 1100 W
- Mode: Fully automatic
- Structure: Adopt split
- Record test result: 100 groups
- Refrigeration method: Automatic forced air cooling
- Air cooling: Automatic when temperature is too high
- Stop: Automatic if there isn't operation after heating 20 minutes
- Heating: Can only be started if press switch 3 seconds,avoiding touch by mistake.
- Safety: Use heat resistant glass interlayer on the heater,avoid oil splash and fire breaking out
- Heating: Dry heating,avoiding toxicity produced by traditional wood's metal heat conduction
- Temperature sensor: Measures oil temperature in crucible directly
- Air cooling: Makes the next test faster
- Pressure gauge: Red oil differential pressure gauge with level meter inside
- Alarm: Buzzer prompts when test is finished
- Lifting system: Automatic
- Opening lid and Ignition: Automatic
- Flame size: Adjustable
- Air cooling: Automatic forced air cooling after test.
- Touch screen: Displays test temperature,number of oil sampler,test time etc
- Working units: 4
- Stirrer: Independent quiet, controls rotating speed, test time and automatically stop
- Liquid circulator: Sputtering multi-channel
- Mixing blade: Sliding automatic
- Safety protection device: Prevent over-low liquid level
- Working units: 1 – 4
- Temperature: Upto 400 °C
- Metal bath heating: Eco-friendly,high effect of heat insulation
- Test bomb: Standard stainless steel with inlet valve of 20m1
- Safety protection device: Air filling and releasing device with pressure gauge,adjusted by needle valve.
- Accuracy: Upto 0.01 s
- Samples size: 2, simultaneously
- Tube: Press-on joint make it easy to dismantle
- Blowing time and Defoaming time control: Automatic
- Liquid circulator: Sputtering multi-channel
- Samples size: 6, simultaneously
- Test samples: Lubricating oil and grease with different cylinders
- Safety: Safety protection device an prevent over-high liquid level
- Metal bath: Eco-friendly heating,no need heat-conducting medium
- Working units: 9
- Stirrer: Digital, rotating, adjustable speed
- Stirring time and record separation time: Automatically controlled
- Unit of separation time: Selective
- Safety: Safety protection device an prevent over-low liquid level
- Working units: 2
- Test sample: Antifreeze
- Temperature control range: Ambient to 20 °C ± 0. 1 °C
- Refrigeration: Shock absorption compressor, fluorine free
- Bath: Low temperature with lighting
- Samples size: 4 groups sample expandable to 8 groups
- Sample bottle: Automatic 360° turn
- Air cooling system: Starts heat radiation automatically when temperature of instrument surface is too high
- Enamel tank: High quality, corrosion resistant, easy to clean with fan circulation and lighting.
- Door: New V type door opening mode, completely transparent high temperature resistant glass door.
- Units: Main unit and gas source controller
- Flow meter: Electronic, controls flow at 94 ± 5 ml/min (optional)
- Air filter: With molecular sieve
- Bath: Refrigerated, 360° circulating, complete transparent.
- Holding device: Special holding device, can prevent cylinder floating upward very well press block is unnecessary.
- Samples size: 8 groups sample simultaneously
- Air cooling system: Starts heat radiation automatically when temperature of instrument surface is too high
- Tank: High quality enamel tank, corrosion resistant and easy to clean
- Fan: With fan circulation and lighting inside.
- Door: New V type door opening mode, completely transparent high temperature resistant glass door.
- Units: Main unit and gas source controller
- Flow meter: Electronic, controls flow at 200 ± 5 ml/min (optional)
- Air filter: With molecular sieve
- Case: Metal protective,with reinforced glass viewing window.
- Holding device: Special holding device, can prevent cylinder floating upward very well press block is unnecessary.
- Probe: Released and lifted automatically
- Cooling speed: 300 °C
- Test medium: Oil, Water, Quench liquid, Saline-alkaline solution, Steel rolling coolant, Cutting fluid.
- Results: Curves of multi test results can be superimposed on one picture to contrast and analyze.
- Display: Maximum cooling speed, Temperature of maximum cooling speed
- Units: Main unit and gas source controller
- Flow meter: Electronic, controls flow at 1000 ± 5 ml/min (optional)
- Air filter: With molecular sieve
- Holding device: Special holding device, can prevent cylinder floating upward very well press block is unnecessary.
- Structure: 360° complete transparent structure,easy to observe
- Samples size: 2 sample simultaneously
- Calculate: Adverage value
- Temperature: - 70 °C
- Refrigerant: Dual air compressors
- Stirrer: Mechanical stirrer, which can avoid uneven mixing and influencing measuring accuracy
- Trough: Two, temperature controlled separately
- Samples size: 2 samples in each trough
- Tempearture Range: Reach -30°C in 30 minutes and the lowest temperature is -70°C ,
- Refrigeration: Dry type over speed refrigeration technology without medium
- Refrigerant: Fluorine free
- Furnace: IR heating furnace no radiation, fast temperature rising speed
- Test requirements: Comply with test requirements of antifreeze and brake fluid
- Glass partition: High temperature resistant
- Display: Control voltage
- Tests: Static and Dynamic
- Motor: Automatic stop when test is finished
- Operation: Observe bearing through reflector with zoom function
- Time: Can edit working time and stop time
- Bearing seat: Made of engineering plastics can avoid corrosive influence
- Working units: 3, can be extended to 4-6 units
- Circulator: Sputtering multi-channel liquid circulator can guarantee temperature uniformity
- Condenser: Quick detachable device
- Safety protection device: Can prevent over-low liquid level
- Motor: fixed speed 600 rpm
- Temperature: Control test temperature at 38 °C and 79 °C as per ASTM standard
- Independent start: Test shaft and Start water pump circulating system
- Shaft: Upgraded connecting shaft can quickly install and dismantle bearing and inside and outside baffle
- Cooling capacity: Can reach to -75 °C
- Motor: Fixed speed
- Refrigerant: Tecumseh compressor
- Time: Automatically controlled
- Viewing window: Transparent and anti-frosting
- Samples size: 4 sample simultaneously
- Flow control system: Independent system, can automatically control flow of every sample.
- Curve of conductivity and Induced knee point: Automatically recorded
- Test curve: Can re-evaluate every test curve
- Software: Functions of multi-curve comparing and curve analysis, measure induced response time and evaluate stable time
- Oxygen: Automatically fill in or discharge oxygen and detect leakage
- Oxygen bombs: Two independent, can work separately
- Pressure-time curve and turning point: Automatic draw and determine
- Safety protection devices: Over-temperature protection device, automatic power off when temperature exceeds set value
- Heating device: Auxiliary heating device guarantees the uniform temperature field of bombs
- Controlling system: SCM controlling system can automatically complete raising temperature, cooling, tempeature recording,printing etc
- Liquid level tracking: High accuracy by laser tracking system
- Flow speed of sample: Controlled within 4 – 5ml every minute from initial boiling point to 95%
- Heating of distillation furnace: Automatically controlled
- Test processes: Complies with standards, data is reliable, can supply initial boiling point and final boiling point
- Igniting device: Ignition source: Coal gas (or civil gas)
- Igniting device: Nozzle aperture: About 0.8 mm
- Thermometer: (-6~400) ℃. Scale is 2 ℃
- Ambient temperature: (15∼35) ℃
- Relative humidity: ≤ 85 %
- Igniting device: Ignition source: Coal gas (or civil gas)
- Igniting device: Flame diameter: 3.2 mm~4.8 mm
- Temperature range: 0 ℃~400 ℃
- Display accuracy: 0.1 ℃
- Temperature control: Single chip microcomputer
- Mode: Electric ignition
- Ignition mode: Gas flame diameter: 3.2 mm~4.8 mm
- Flash point determination: Range: Ambient to 400℃
- Repeatability: ≤ 8℃ (Flash Point)
- Reproducibility: ≤ 17 ℃ (Flash Point)
- Mode: Electric ignition
- Ignition mode: Diameter of igniter: 0.7 mm~0.8 mm
- Heating rate: Initial heating: 14~17 ℃/min
- Heating_rate: It is (5-6)℃/ min after reaching the preset flash point 20℃
- Flash point determination: Range: Ambient to 400 ℃
- Oil cup: Inner diameter: 50.7 mm~50.8 mm
- Oil cup: Depth: 55.7 mm~56.0 mm
- Oil cup: The scribed line depth of capacity of testing oil: 33.9mm~34.3mm
- Oil cup: Capacity of testing oil: About 70ml
- Igniting source: Gas(or other civilian fuels)
- Heating device: (1) The furnace is silicon carbide material. Power is 600W. (2) The heating power is adjustable from 0 W to 600W
- Heating_rate: Procedure A: (5~6)℃/min, Procedure B: (1~1.5)℃/min
- Stirring device: (1)Stirring motor: BYGH101 stepping motor. (2) Driving mode: flexible shaft. (3) Shaft size: 8mm×40mm
- Stirring rate: Procedure A: (90~120) rpm, Procedure B: (250±10) rpm
- Stand oil cup: Internal diameter: 50.7mm~50.8mm
- Heating rate: Procedure A: (5~6) ℃/min
- Heating rate: Procedure B: (1~1.5) ℃/min
- Heating rate: Procedure C: (3.0±0.5) ℃/min
- Stirring rate:Procedure A and C: (90~120) rpm
- Stirring rate:Procedure B: (250±10) rpm
- Flash point measuring range: -30℃~+50℃
- Temperature resolution: ± 0.1℃
- Igniting device: Electric igniting gun
- Cooling mode: Semiconductor(with cold water cycle at external connection)
- Igniting source: Gas,LPG(or other civilian fuels)
- Flash point measuring range: -10℃~+100℃
- Temperature resolution: ± 0.1℃
- Igniting device: Electric igniting gun
- Cooling mode: Semiconductor(with cold water cycle at external connection)
- Igniting source: Gas,LPG(or other civilian fuels)
- Heating control: Can be continuously adjusted by a silicon knob, manual.
- Ambient temperature: (15-35)℃
- Relative humidity: ≤ 85%
- Power supply: AC(220±10%)V,50Hz
- Total power consumption: ≤2200 W
- Capillary viscometer tubes: 6 pieces in total, inner diameter for each:0.6mm, 0.8mm, 1.0mm, 1.2mm, 1.5mm, 2.0mm
- Temperature control range: Ambient to 100℃
- Temperature control accuracy: ±0.1℃
- Temperature sensor: RTD, Pt100
- Timing range: 0s~9999.9s
- Capillary viscometer tubes: 6 pieces in total, inner diameter for each:0.6mm, 0.8mm, 1.0mm, 1.2mm, 1.5mm, 2.0mm
- Temperature control range: Ambient to 100℃
- Temperature control accuracy: ±0.1℃
- Temperature sensor: RTD, Pt100
- Timing range: 0s~9999.9s
- Capillary viscometer tubes: 6 pieces in total. The inner diameter for each: 0.6mm, 0.8mm, 1.0mm, 1.2mm, 1.5mm, 2.0mm
- Amount of capillary viscometer tubes: 4 capillary viscometers
- Bath capacity: 20L
- Working condition: 15℃~35℃
- Relative humidity: ≤ 85%
- Distillation flask: 125 ml
- Water bath temperature controlling: Range: (ambient temp.+10)℃~60℃
- Water bath temperature controlling: Accuracy: ±0.5℃
- Receiving cylinder: 100ml,scale division 1ml
- Ambient temperature: 15℃~35℃
- Distillation flask: 125 ml
- Receiving cylinder: 100 ml,scale division 1 ml
- Temperature controller: Range: (Ambient +10)℃~60℃
- Temperature controller: Accuracy: ±0.5℃
- Temperature controller: Display: LED
- Distillation flask: 125 ml
- Receiving cylinder: 100 ml,scale division 1 ml
- Thermometer: (-2~300)℃ and (-2~400)℃, division value 1℃
- Furnace heating power: 1300W*2
- Condenser temperature controlling: Range: 0 ℃ to 60 ℃
- Distillation flask: 125 ml
- Receiving cylinder: 100 ml,scale division 1 ml
- Heating power: ≤2300W
- Electric furnace heating power: 1300W
- Thermometer: Total immersion. They are from ( -2 to 300 )℃ and from (-2 to 400) ℃. The scale divisions of them are 1 ℃
- Temperature range of bath: (0~60)℃
- Temperature control precision of bath: ±0.5℃
- Temperature range of receiving chamber: (0~60)℃
- Temperature control precision of receiving chamber: ±1℃
- Distillate liquid detection: (0~100) ml,resolution 0.01 ml
- Capacity of buffer vessel: 1000 ml
- Heating power:Heater for distillation flask: 1300W
- Heating power:Heater for receiver: 350W
- Heating furnace of distillation flask: (0~1300)W, continuously adjustable
- Max. residual pressure: 2 mmHg
- Heating furnace of distillation flask: (0~1300)W, adjustable
- Setting range of vacuum residual pressure: (2~50) mmHg
- Accuracy of vacuum residual pressure: ±0.5 mmHg
- Heating power of receiver: 350W,automatically controlled
- Temperature control point of receiver: (20~50)℃±3℃, adjustable
- Temperature control range of condensate circulating water: Ambient+5℃(Min. 30℃)~80℃±3℃; adjustable
- Working Mode of condensate trap: Semiconductor refrigeration
- Minimum temperature: ≤ - 40 ℃
- Absolute pressure setting: 2 mmhg, 5 mmhg, 10 mmhg, 20 mmhg, 50 mmhg
- Absolute pressure measurement range: (2.00-170.00) mmHg ± 0.01 mmHg automatic constant pressure
- Capacity of cylinder: 500ml
- Temperature controller: Range: (Ambient +5)℃ to 100℃
- Temperature controller: Accuracy: ±0.2℃
- Temperature controller: Sensor: Pt100
- Dimension of constant temperature bath: Ф300mm×340mm
- Working chamber: Two test baths in one chamber. The temperatures are the same.
- Temperature controller: Range: Ambient to -70℃
- Temperature controller: Accuracy: ±0.5℃
- Refrigeration: New-type refrigeration compressor
- Ambient temperature: ≤30℃
- Cold bath temperature control: Chamber I: -17℃~0℃,accuracy±0.5℃, temperatures in two cold baths are the same.
- Cold bath temperature control: Chamber II: -30℃
- Cold bath temperature control: Chamber III: -51℃~-34℃,accuracy±0.5℃,temperatures in two cold baths are the same.
- Cold bath temperature control: Chamber IV: -70℃
- Suitable temperature: 15℃~28℃
- Freezing point range: -54℃~2℃
- Working bath: stainless steel,double vacuum glass observing window.
- Cold bath measurement temperature: -70℃~30℃
- Temperature controlling accuracy: ±0.1℃
- Sample stirring: mechanical stirring is(60~80)r/min,continuously adjustable
- Sample testing positions: Four positions
- Sample quantity at one test: 4 pieces~12 pieces
- Temperature range: Ambient to 100 ℃,can be set at will
- Temperature control accuracy: ±1 ℃
- Time controlling range: 1 minute~24 hours, can be set at will.
- Test furnace: One furnace with four holes
- Heating mode: Electric furnace
- Temp. Control range: (0~520)℃
- Temp. Control accuracy: ±5℃
- Ambient temperature: Room temperature~ 35℃
- Temperature of coke chamber: 500℃
- Temperature control accuracy: ±2 ℃
- Heating power: 1200W
- Ambient temperature: 5℃~35℃
- Relative humidity: ≤ 85%
- Timing range: 1s∼9min59s
- Stirring rate: (1500±15)r/min
- Temperature range: (Room temp.+5∼99.9)℃
- Temperature control accuracy: ±1℃
- Ambient temperature: 15℃~35℃
- Testing hole: 4 sample
- Stirring rate: (1500±15)r/min
- Stirring time: (0~99)min
- Timing: (0~99)h
- Temperature range: (Room temp.∼110)℃
- Temperature control range for high temperature bath: (Room temp.~99.9)℃
- Temperature control range for low temperature bath: (5~99.9)℃
- Temperature control accuracy: ±0.5℃
- Air flow rate: (94±5)ml/min,adjustable
- Timer: 5min and 10min,accurate to second
- Sample positions: 5 positions
- Dimension of sample position: φ51mm×70mm
- Working temperature: (160~165)℃
- Dimension of evaporation bath: φ260mm×130mm
- Temperature control method: Automatic
- Temperature control range of bath: (Room temp.~90)℃
- Temperature control accuracy of bath: ±0.1℃
- Accuracy of pressure meter: 0.4%F·S
- Ambient temperature: 15℃~35℃
- Relative humidity: ≤ 85%
- Test bomb: Can do 3 bomb tests at the same time
- Water bath temperature: 37.8℃
- Pressure range: (0~200)kPa or (0~29)psi
- Temperature control accuracy: ±0.1℃
- Ambient temperature: 15℃~35℃
- Heating Tube Power: ≤1000W, The actual heating power is automatically controlled by the computer
- Measuring range of oxygen bomb pressure transmitter: (0~1600)kPa, accuracy:±2%
- Temperature control point of metal bath: 100.0℃±0.5℃
- Thermometer: Mercury-in glass thermometer, can correct coefficient as need
- Ambient temperature: ≤40℃
- Sample quantity: It can determine 6 samples at a time
- Temperature measuring component: Thermal resistance
- Temperature control mode: Automatically controlled by digital temperature controller
- Temperature control range: Ambient to 100℃
- Temperature control accuracy: ±0.2℃
- Test sample: Two-bomb design, can do two samples at one time. Convenient to do parallel test.
- Rotation speed: (100±1)r/min
- Included angle between oxygen bomb and water level: 30°
- Range for pressure sensor: (0~1.6)MPa
- Accuracy: ±2%
- Air supply: Nitrogen cylinder (or air compressor,compressed air bottle)
- Pressure regulating range of reducing valve: (0~400)kPa
- Electric agitator: independently controlled for each way
- Ultraviolet light source pipe: 1220mm in length,wavelength is 365mm±5nm
- Illuminating lamp: 1220mm in length,power is 40W
- Oil Bath: 600ml Beaker
- Grease Cup: It is made of chrome plated brass, inner diameter: 9.92mm, oil dripping hole:2.8mm, cup height: 12mm
- Test Tube: Heat resistant borosilicate glass tube with edge, inner diameter: 11.1 mm to 12.7 mm, and there are three grooves on the circumference 19 mm away from the bottom to support the grease cup
- Stirring motor: 60 R / min
- Working environment:Temperature: (- 5 ~ 300) ℃
- Oil sample quantity: 6ml
- Powder sample quantity: 3g
- Detection limit: 50 ppm
- Measuring range: 0.005%~5%
- Repeatability (r): <0.4347 X0.6446
- Temperature control range for water bath: Room temperature~90 ℃, adjustable
- Bath temperature display: Digitally displayed by LED
- Temperature control accuracy for water bath: ±1 ℃
- Temperature control range for funnel: Room temperature~90 ℃, adjustable
- Temperature control accuracy for funnel: ±2 ℃
- Box-type heating furnace: Rated temperature: 1000℃
- Box-type heating furnace: Temperature rising time for empty furnace: ≤50 min
- Box-type heating furnace: Power consumption for empty furnace: ≤800W
- Box-type heating furnace: Furnace temperature uniformity: ≤15℃
- Box-type heating furnace: Heat savings: ≤5kW.h
- Light_source: 220 V, 100 W
- Light source: temperature: 2750±50 K
- Observation lens composition: concave mirror and separated bar
- Standard color dial: 26 pieces of Φ14 light holes
- Color comparing tube: Φ32 mm, 120~130 mm high non-colorful flat bottom glass tube
- Temperature range: Ambient to 200℃
- Temperature precision: ≤0.5℃
- Heating power: ≤2100W
- Ambient temperature: 15℃~35℃
- Relative humidity: ≤ 85%
- Distillation flask: 1000 ml
- Receiver: 5ml,graduation is 0.05 ml
- Condenser: 400mm±5mm
- Heater: heating mantle cap,500W×2,continuous adjustment
- Ambient temperature: -10℃~+35℃
- Burette volume: 10ml
- Burette precision: ±0.1%F•S
- Burette dripping time: (60±20)S(F·S)
- Potential measurement range: (0~±1800.0)mV
- Basic error of electronic unit: 0.1%±0.5mV of full reading
- Viscosity measurement range: 1500mPa•s ~27000mPa•s
- Cold bath temperature control range: Ambient ~ -60℃
- Cold bath temperature control accuracy: ±0.5℃
- Stator temperature control accuracy: ±0.05℃
- Environment temperature: 10℃~40℃