Microwave Digester
A well-known method for preparing solid materials into solutions fit for examination by ICP-AES, ICP-MS, atomic absorption spectroscopy, or polarography is microwave digestion.
Operating Manuals
(16) items
Go
Series : 100
Vessel Quantity : 6 8 10 6 8 10 12 12 18 40
Microwave Digester BMWD-101
- Vessel Quantity: 6
- Temperature Monitoring System: Contactless IR sensor All vessels scanning monitoring
- Pressure Monitoring System: Contactless pressure sensors. All vessels scanning monitoring
- Working Pressure Range: 0-6MPa
- Working Temperature Range: 50-400 °C Accuracy: ±0.1 °C
Microwave Digester BMWD-102
- Vessel Quantity: 8
- Pressure Monitoring System: Contactless pressure sensors. All vessels scanning monitoring
- Working Pressure Range: 0-6MPa
- Working Temperature Range: 50-400 °C Accuracy: ±0.1°C
- Vessel Volume: 100mL
Microwave Digester BMWD-103
- Vessel Quantity: 10
- Pressure Monitoring System: Contactless pressure sensors. All vessels scanning monitoring
- Working Pressure Range: 0-6MPa
- Working Temperature Range: 50-400 °C Accuracy: ±0.1 °C
- Vessel Volume: 100mL
Microwave Digester BMWD-104
- Vessel Quantity: 6
- Temperature Monitoring System: Temperature Monitoring: Contactless IR Sensor Scan monitoring for each vessel Temperature Controlling Range: 50-400 ?C Temperature Accuracy: ?0.1 ?C Display Accuracy: ?0.1 ?C
- Pressure Monitoring System: Pressure monitoring: Contactless Sensor Scan monitoring for each vessel Pressure Controlling Range: 0-15MPa Pressure Accuracy:?0.01MPa Display Accuracy: ?0.01Mpa
- Vessel Volume: 100mL
- Sample Vessel Material: lmported TFM
Microwave Digester BMWD-105
- Vessel Quantity: 8
- Temperature Monitoring System: Temperature Monitoring: Contactless IR Sensor Scan monitoring for each vessel Temperature Controlling Range: 50-400 ?C Temperature Accuracy: ?0.1 ?C Display Accuracy: ?0.1 ?C
- Pressure Monitoring System: Pressure monitoring: Contactless Sensor Scan monitoring for each vessel Pressure Controlling Range: 0-15MPa Pressure Accuracy:?0.01MPa Display Accuracy: ?0.01Mpa
- Vessel Volume: 100mL
- Sample Vessel Material: lmported TFM
Microwave Digester BMWD-106
- Vessel Quantity: 10
- Temperature Monitoring System: Temperature Monitoring: Contactless IR Sensor Scan monitoring for each vessel Temperature Controlling Range: 50-400 ?C Temperature Accuracy: ?0.1 ?C Display Accuracy: ?0.1 ?C
- Pressure Monitoring System: Pressure monitoring: Contactless Sensor Scan monitoring for each vessel Pressure Controlling Range: 0-15MPa Pressure Accuracy:?0.01MPa Display Accuracy: ?0.01Mpa
- Vessel Volume: 100mL
- Sample Vessel Material: lmported TFM
Microwave Digester BMWD-107
- Vessel Quantity: 12
- Temperature Monitoring System: Temperature Monitoring: Contactless IR Sensor Scan monitoring for each vessel Temperature Controlling Range: 50-400 ?C Temperature Accuracy: ?0.1 ?C Display Accuracy: ?0.1 ?C
- Pressure Monitoring System: Pressure monitoring: Contactless Sensor Scan monitoring for each vessel Pressure Controlling Range: 0-15MPa Pressure Accuracy:?0.01MPa Display Accuracy: ?0.01Mpa
- Vessel Volume: 100mL
- Sample Vessel Material: lmported TFM
Microwave Digester BMWD-108
- Vessel Quantity: 12
- Vessel Volume: 100mL
- Vessel material: Inner.Imported TFM Outer.Imported PEEK+Glass Fiber
- Temperature Monitoring System: Contactless IR sensor
- Temperature Control: Scanning control of each vessel
Microwave Digester BMWD-109
- Vessel Quantity: 18
- Vessel Volume: 100mL
- Vessel material: Inner.Imported TFM Outer.Imported PEEK+Glass Fiber
- Temperature Monitoring System: Contactless IR sensor
- Temperature Control: Scanning control of each vessel
Microwave Digester BMWD-110
- Vessel Quantity: 40
- Vessel Volume: 50mL
- Vessel material: Inner.Imported TFM Outer.Imported PEEK Glass Fiber
- Temperature Monitoring System: Contactless IR sensor
- Temperature Control: Scanning control of each vessel
Series : 200
Vessel Quantity : 12126RT +5 ± 450 °C12pcs40pcs
Microwave Digester BMWD-201
- Vessel Quantity: 12
- Vessel Volume: 100mL
- Vessel Pressure Capacity: 80Mpa
- Cavity: 48L Resonant Cavity
- Microwave Cavity Material: SS316 with 10 layers Telflon
Microwave Digester BMWD-202
- Vessel Quantity: 12
- Vessel Volume: 100mL
- Vessel Pressure Capacity: 75Mpa
- Cavity: 48L Resonant Cavity
- Microwave Cavity Material: SS316 with 8 layers Telflon
Microwave Digester BMWD-203
- Vessel Quantity: 6
- Vessel Volume: 100mL
- Vessel material: Aerospace composite fiber for outer Vessel, Modified TFM material for inner Vessel
- Temperature Range: 0-300 °C
- Temperature Control Accuracy: ±1 °C
Microwave Digester BMWD-204
- Temperature Range: RT +5 ± 450 °C
- Temperature Accuracy: ±1 °C (450 °C)
- Heating Method: Infrared heating and high-purity graphite conduction
- Heating Insulation Method: Unique air duct insulation technology
- Digestion Tube Capacity: 300ml
Microwave Digester BMWD-205
- Vessel Quantity: 12pcs
- Accuracy: ±1 °C
- Maximum Working Temperature: 240 °C
- Hole Diameter: 39.5 mm
- Hole Depth: 107 mm
Microwave Digester BMWD-206
- Vessel Quantity: 40pcs
- Vessel Volume: 55mL
- Vessel material: TFM
- Temperature Range: 0-300 °C
- Temperature Control Accuracy: ±1 °C