Microwave Digester

Microwave Digester

 

A well-known method for preparing solid materials into solutions fit for examination by ICP-AES, ICP-MS, atomic absorption spectroscopy, or polarography is microwave digestion.

 
(16) items
Compare Selected (0)
Go
Series : 100
Vessel Quantity : 6 8 10 6 8 10 12 12 18 40
Microwave Digester BMWD-101

Microwave Digester BMWD-101

  • Vessel Quantity: 6
  • Temperature Monitoring System: Contactless IR sensor All vessels scanning monitoring
  • Pressure Monitoring System: Contactless pressure sensors. All vessels scanning monitoring
  • Working Pressure Range: 0-6MPa
  • Working Temperature Range: 50-400 °C Accuracy: ±0.1 °C
Microwave Digester BMWD-102

Microwave Digester BMWD-102

  • Vessel Quantity: 8
  • Pressure Monitoring System: Contactless pressure sensors. All vessels scanning monitoring
  • Working Pressure Range: 0-6MPa
  • Working Temperature Range: 50-400 °C Accuracy: ±0.1°C
  • Vessel Volume: 100mL
Microwave Digester BMWD-103

Microwave Digester BMWD-103

  • Vessel Quantity: 10
  • Pressure Monitoring System: Contactless pressure sensors. All vessels scanning monitoring
  • Working Pressure Range: 0-6MPa
  • Working Temperature Range: 50-400 °C Accuracy: ±0.1 °C
  • Vessel Volume: 100mL
Microwave Digester BMWD-104

Microwave Digester BMWD-104

  • Vessel Quantity: 6
  • Temperature Monitoring System: Temperature Monitoring: Contactless IR Sensor Scan monitoring for each vessel Temperature Controlling Range: 50-400 ?C Temperature Accuracy: ?0.1 ?C Display Accuracy: ?0.1 ?C
  • Pressure Monitoring System: Pressure monitoring: Contactless Sensor Scan monitoring for each vessel Pressure Controlling Range: 0-15MPa Pressure Accuracy:?0.01MPa Display Accuracy: ?0.01Mpa
  • Vessel Volume: 100mL
  • Sample Vessel Material: lmported TFM
Microwave Digester BMWD-105

Microwave Digester BMWD-105

  • Vessel Quantity: 8
  • Temperature Monitoring System: Temperature Monitoring: Contactless IR Sensor Scan monitoring for each vessel Temperature Controlling Range: 50-400 ?C Temperature Accuracy: ?0.1 ?C Display Accuracy: ?0.1 ?C
  • Pressure Monitoring System: Pressure monitoring: Contactless Sensor Scan monitoring for each vessel Pressure Controlling Range: 0-15MPa Pressure Accuracy:?0.01MPa Display Accuracy: ?0.01Mpa
  • Vessel Volume: 100mL
  • Sample Vessel Material: lmported TFM
Microwave Digester BMWD-106

Microwave Digester BMWD-106

  • Vessel Quantity: 10
  • Temperature Monitoring System: Temperature Monitoring: Contactless IR Sensor Scan monitoring for each vessel Temperature Controlling Range: 50-400 ?C Temperature Accuracy: ?0.1 ?C Display Accuracy: ?0.1 ?C
  • Pressure Monitoring System: Pressure monitoring: Contactless Sensor Scan monitoring for each vessel Pressure Controlling Range: 0-15MPa Pressure Accuracy:?0.01MPa Display Accuracy: ?0.01Mpa
  • Vessel Volume: 100mL
  • Sample Vessel Material: lmported TFM
Microwave Digester BMWD-107

Microwave Digester BMWD-107

  • Vessel Quantity: 12
  • Temperature Monitoring System: Temperature Monitoring: Contactless IR Sensor Scan monitoring for each vessel Temperature Controlling Range: 50-400 ?C Temperature Accuracy: ?0.1 ?C Display Accuracy: ?0.1 ?C
  • Pressure Monitoring System: Pressure monitoring: Contactless Sensor Scan monitoring for each vessel Pressure Controlling Range: 0-15MPa Pressure Accuracy:?0.01MPa Display Accuracy: ?0.01Mpa
  • Vessel Volume: 100mL
  • Sample Vessel Material: lmported TFM
Microwave Digester BMWD-108

Microwave Digester BMWD-108

  • Vessel Quantity: 12
  • Vessel Volume: 100mL
  • Vessel material: Inner.Imported TFM Outer.Imported PEEK+Glass Fiber
  • Temperature Monitoring System: Contactless IR sensor
  • Temperature Control: Scanning control of each vessel
Microwave Digester BMWD-109

Microwave Digester BMWD-109

  • Vessel Quantity: 18
  • Vessel Volume: 100mL
  • Vessel material: Inner.Imported TFM Outer.Imported PEEK+Glass Fiber
  • Temperature Monitoring System: Contactless IR sensor
  • Temperature Control: Scanning control of each vessel
Microwave Digester BMWD-110

Microwave Digester BMWD-110

  • Vessel Quantity: 40
  • Vessel Volume: 50mL
  • Vessel material: Inner.Imported TFM Outer.Imported PEEK Glass Fiber
  • Temperature Monitoring System: Contactless IR sensor
  • Temperature Control: Scanning control of each vessel
Series : 200
Vessel Quantity : 12126RT +5 ± 450 °C12pcs40pcs
Microwave Digester BMWD-201

Microwave Digester BMWD-201

  • Vessel Quantity: 12
  • Vessel Volume: 100mL
  • Vessel Pressure Capacity: 80Mpa
  • Cavity: 48L Resonant Cavity
  • Microwave Cavity Material: SS316 with 10 layers Telflon
Microwave Digester BMWD-202

Microwave Digester BMWD-202

  • Vessel Quantity: 12
  • Vessel Volume: 100mL
  • Vessel Pressure Capacity: 75Mpa
  • Cavity: 48L Resonant Cavity
  • Microwave Cavity Material: SS316 with 8 layers Telflon
Microwave Digester BMWD-203

Microwave Digester BMWD-203

  • Vessel Quantity: 6
  • Vessel Volume: 100mL
  • Vessel material: Aerospace composite fiber for outer Vessel, Modified TFM material for inner Vessel
  • Temperature Range: 0-300 °C
  • Temperature Control Accuracy: ±1 °C
Microwave Digester BMWD-204

Microwave Digester BMWD-204

  • Temperature Range: RT +5 ± 450 °C
  • Temperature Accuracy: ±1 °C (450 °C)
  • Heating Method: Infrared heating and high-purity graphite conduction
  • Heating Insulation Method: Unique air duct insulation technology
  • Digestion Tube Capacity: 300ml
Microwave Digester BMWD-205

Microwave Digester BMWD-205

  • Vessel Quantity: 12pcs
  • Accuracy: ±1 °C
  • Maximum Working Temperature: 240 °C
  • Hole Diameter: 39.5 mm
  • Hole Depth: 107 mm
Microwave Digester BMWD-206

Microwave Digester BMWD-206

  • Vessel Quantity: 40pcs
  • Vessel Volume: 55mL
  • Vessel material: TFM
  • Temperature Range: 0-300 °C
  • Temperature Control Accuracy: ±1 °C