Get Price

Microwave Digester

Microwave Digester
16 products
No products match the selected specifications. Clear one or more filters to see products.
Microwave Digester
Graphite Digester
Temperature Range: RT +5~450°C
Temperature Accuracy: ±1°C(450°C)
Heating Method: Infrared heating and high-purity graphite conduction
Heating Insulation Method: Unique air duct insulation technology
Microwave Digester
Microwave Digestion System
Vessel Quantity: 6
Pressure Monitoring: Contactless pressure sensor
Max Working Pressure Range: 6MPa
Temperature Monitoring: Contactless IR sensor
Microwave Digester
Microwave Digestion System
Vessel Quantity: 8
Pressure Monitoring: Contactless pressure sensor
Max Working Pressure Range: 6MPa
Temperature Monitoring: Contactless IR sensor
Microwave Digester
Microwave Digestion System
Vessel Quantity: 10
Pressure Monitoring: All vessels scanning monitoring
Max Working Pressure Range: 6MPa
Temperature Monitoring: All vessels scanning monitoring
Microwave Digester
Microwave Digestion System
Vessel Quantity: 6
Temperature Monitoring: Contactless IR Sensor Temperature MonitoringEach Vessel Temperature ControlledTemperature Controlling Range: 50-400°CMax. Working Temperature: 250°CTemperature Accuracy: ±0.1°C
Pressure Monitoring: Contactless Sensor Pressure monitoringEach Vessel Pressure ControlledPressure Controlling Range: 0-15MPaMax. Working Pressure: 6MPaPressure Accuracy: ±0.01MPa
Vessel Volume: 100mL
Microwave Digester
Microwave Digestion System
Vessel Quantity: 8
Temperature Monitoring: Contactless IR Sensor Temperature MonitoringEach Vessel Temperature ControlledTemperature Controlling Range: 50-400°CMax. Working Temperature: 250°CTemperature Accuracy: ±0.1°C
Pressure Monitoring: Contactless Sensor Pressure monitoringEach Vessel Pressure ControlledPressure Controlling Range: 0-15MPaMax. Working Pressure: 6MPaPressure Accuracy: ±0.01MPa
Vessel Volume: 100mL
Microwave Digester
Microwave Digestion System
Vessel Quantity: 10
Temperature Monitoring: Contactless IR Sensor Temperature MonitoringEach Vessel Temperature ControlledTemperature Controlling Range: 50-400°CMax. Working Temperature: 250°CTemperature Accuracy: ±0.1°C
Pressure Monitoring: Contactless Sensor Pressure monitoringEach Vessel Pressure ControlledPressure Controlling Range: 0-15MPaMax. Working Pressure: 6MPaPressure Accuracy: ±0.01MPa
Vessel Volume: 100mL
Microwave Digester
Microwave Digestion System
Vessel Quantity: 12
Temperature Monitoring: Contactless IR Sensor Temperature MonitoringEach Vessel Temperature ControlledTemperature Controlling Range: 50-400°CMax. Working Temperature: 250°CTemperature Accuracy: ±0.1°C
Pressure Monitoring: Contactless Sensor Pressure monitoringEach Vessel Pressure ControlledPressure Controlling Range: 0-15MPaMax. Working Pressure: 6MPaPressure Accuracy: ±0.01MPa
Vessel Volume: 100mL
Microwave Digester
Microwave Digestion System
Vessel Quantity: 12
Temperature Monitoring: Contactless IR Sensor Temperature Monitoring; Each Vessel Temperature Controlled; Temperature Controlling Range: 50-400°C; Max. Working Temperature: 250°C; Temperature Accuracy: ±0.1°C
Pressure Monitoring: Contactless Sensor Pressure Monitoring; Each Vessel Pressure Controlled; Pressure Controlling Range: 0-15 MPa; Max. Working Pressure: 6 MPa; Pressure Accuracy: ±0.01 MPa
Vessel Volume: 100 mL
Microwave Digester
Microwave Digestion System
Vessel Quantity: 18
Temperature Monitoring: Contactless IR Sensor Temperature Monitoring; Each Vessel Temperature Controlled; Temperature Controlling Range: 50-400°C; Max. Working Temperature: 250°C; Temperature Accuracy: ±0.1°C
Pressure Monitoring: Contactless Sensor Pressure Monitoring; Each Vessel Pressure Controlled; Pressure Controlling Range: 0-15 MPa; Max. Working Pressure: 6 MPa; Pressure Accuracy: ±0.01 MPa
Vessel Volume: 100 mL
Microwave Digester
Microwave Digestion System
Vessel Quantity: 40
Temperature Monitoring: Contactless IR Sensor Temperature Monitoring; Each Vessel Temperature Controlled; Temperature Controlling Range: 50-400°C; Max. Working Temperature: 250°C; Temperature Accuracy: ±0.1°C
Pressure Monitoring: Contactless Sensor Pressure monitoring; Each Vessel Pressure Controlled; Pressure Controlling Range: 0-15 MPa; Max. Working Pressure: 6 MPa; Pressure Accuracy: ±0.01 MPa
Vessel Volume: 50 mL
Microwave Digester
Microwave Digester
Vessel Quantity: 12pcs
Accuracy: ±1 °C
Maximum Working Temperature: 240 °C
Hole Diameter: 39.5 mm
Microwave Digester
Microwave Digester
Vessel Quantity: 6
Vessel Volume: 100mL
Vessel Material: Aerospace composite fiber for outer Vessel, Modified TFM material for inner Vessel
Temperature Range: 0-300 °C
Microwave Digester
Microwave Digester
Vessel Quantity: 12
Vessel Volume: 100 mL
Vessel Pressure Capacity: 75 MPa
Cavity: 48 L Resonant Cavity
Microwave Digester
Microwave Digester
Vessel Quantity: 12
Vessel Volume: 100 mL
Vessel Pressure Capacity: 80 MPa
Cavity: 48 L Resonant Cavity
Microwave Digester
Microwave Digester
Vessel Quantity: 40 pcs
Vessel Volume: 55 mL
Vessel Material: TFM
Temperature Range: 0-300 °C
0/6 selected