Colorimeter BHJ1C1

Differential Scanning Calorimeter
  • Sea, Air, Door to Door Shipping
  • 1 Year Warranty
  • US & European Standards



Colorimeter -40°C ~ 600°C 0.01°C

Specifications

ModelBHJ1C1
Temperature range-40°C ~ 600°C
Temperature resolution0.01°C
Temperature fluctuation±0.01°C
Temperature repeatability±0.1°C
Heating rate0.1 ~ 100°C/min
Cooling rate0.1 ~ 20°C/min
Constant temperature timeProgram setting ≤ 24h
Curve scanningHeating scan, Cooling scan
DSC range0 ~ ±800 mW
DSC resolution0.01 μW
DSC accuracy0.001 mW
Temperature control modeHeating, constant temperature, and cooling
Working power supplyAC 220V 50Hz or customized
Atmosphere control gasNitrogen, oxygen (instrument automatic switch)
Gas flow0 ~ 300 mL/min
Gas pressure0.3 MPa
Display mode24-bit color, 7-inch LCD touch screen display
Data interfaceStandard USB interface
Parameter standardEquipped with reference materials (indium, tin, lead) - user can correct temperature manually
Thermocouple configurationMultiple thermocouples: one for sample temperature, one for instrument internal ambient temperature

Description

The DSC is a touch screen type, which can be used for glass transition temperature test,
phase transition test, melting and enthalpy test, product stability and oxidation induction
period test.Wide range of application.

Features

1. Industrial grade 7-inch touch screen with rich display information.
2. New metal furnace structure, better baseline and higher accuracy. Indirect conduction
mode is adopted for heating, which has high uniformity and stability, reduces pulse radiation, and is superior to the traditional heating mode.
3. USB communication interface has strong universality, reliable and uninterrupted communication, and supports self recovery connection function.
4. Automatic switching of two-way atmosphere flow, fast switching speed and short stability time. At the same time, one protective gas input is added.
5. The software is simple and easy to operate.


1. Industrial grade 7-inch touch screen with rich display information. 2. New metal furnace structure, better baseline and
Furnace structure

Melting point, heat enthalpy, phase change temperature analysis :
Melting point, heat enthalpy, phase change temperature analysis : Glass analysis: Colorimeter -40°C ~ 600°C 0.01°C
Glass analysis:
Melting point, heat enthalpy, phase change temperature analysis : Glass analysis: Colorimeter -40°C ~ 600°C 0.01°C

Initial melting point, final melting point analysis:
Initial melting point, final melting point analysis: Colorimeter -40°C ~ 600°C 0.01°C

Analysis of two or more section lifting temperatures:
Analysis of two or more section lifting temperatures: Colorimeter -40°C ~ 600°C 0.01°C

Test report:
Test report: Colorimeter -40°C ~ 600°C 0.01°C




Request Quote
Name*:
Email*:
I am *: Distributor End User Others
WhatsApp :
Product :
Subject :
Message :