Single Beam UV Visible Spectrophotometer BHV1C6 (BSSBV-304-PC)

Spectrophotometer
  • Sea, Air, Door to Door Shipping
  • 1 Year Warranty
  • US & European Standards



Single Beam UV Visible Spectrophotometer 320-1100 nm 2 nm

Specifications

ModelBHV1C6
Wavelength Range320-1100 nm
Spectral Bandwidth2 nm
Optical SystemSingle Beam, Grating 1200 lines/mm
Wavelength Accuracy±0.5 nm
Wavelength Repeatability0.3 nm
Photometric Accuracy±0.5%T or ±0.004A @ 1A
Photometric Range0-200%T,-0.3-3 A, 0-9999 Conc
Stray Light0.05%T @ 360 nm
Stability±0.001 A/h @ 500 nm
DisplayGraphic LCD (128*64 dots)
Keyboard22 Membrane keypad
Standard Cell HolderStandard 10 mm pathlength cuvette
Sample Compartment4-position 10 mm cell changer
Light SourceTungsten lamp
OutputUSB Port & Parallel Port (Printer)
Power RequirementAC 110/220 V 50/60 Hz
Dimensions (LxWxH)470x373x187 mm
Weight12 kg

Description

Simple-to-use instruments with advanced performance, its stray light is only 0.05%T. The local stand-alone software provides functions of Photometry, Quantitative Test, Kinetics and System Utilities functions.

Features

Large LCD screen (128*64 Dots).
The system can also save the test results, a total of 200 groups of data and 200 standard curves can be saved in the RAM. Convenient for check and reload.
Data can be restored after a sudden power cut.
Auto setting wavelength.
Tungsten lamp & Deuterium lamp can be turned on/off individually to extend lifetime.
The optional application software M. Wave Professional provides complete control of the spectrophotometer from a computer through the built-in USB port. It can expand to the following functions: Quantitative, Kinetics, Wavelength Scan, Multi-wavelength & DNA/Protein Test.
Pre-aligned design makes it convenient to change lamps.
Large sample compartment; it can accommodate 5-100 mm path length cuvettes with optional holders. A variety of optional accessories are available.


Main Menu:
Move the cursor on the function menu you want, then press ENTER key to go into the corresponding interface.
Large LCD screen (128*64 Dots). The system can also save the test results, a total of 200 groups of data and 200 standard

Basic Mode:
Absorbance, Transmittance or Concentration measurements.
It can display and save 200 groups of data, 5 groups per screen.
Basic Mode: Absorbance, Transmittance or Concentration measurements. It can display and save 200 groups of data, 5 groups

Kinetics:
This mode may be used for time course scanning or reaction rate calculations. Abs. VS Time graphs are displayed on the screen in real time. It can record 1000 data.
Kinetics: This mode may be used for time course scanning or reaction rate calculations. Abs. VS Time graphs are displayed on

Quantitative:
Standard Curve
At most, 9 standard samples can be used to establish a standard curve. The curve and its equation will be displayed on the screen simultaneously. You can measure your unknown concentration solutions by the curve. Total 200 curves can be saved in the RAM.
Coefficient Method
If you have known the coefficient K*a + b is known, you can input them directly by the button, and then test your unknown solutions.
Quantitative: Standard Curve At most, 9 standard samples can be used to establish a standard curve. The curve and its

System Utilities:
Lamp management, time & date set, obtain dark current, calibrate wavelength, default system, and some other system functions.
System Utilities: Lamp management, time & date set, obtain dark current, calibrate wavelength, default system, and some


M. Wave Professional PC-Control Software:

Brief Introduction:
M. Wave Professional application software is based Microsoft Windows, the instrument can be controlled by PC software through the built-in USB communication port, which makes the UV/Vis Series with more functions and easy to control.

Quantitative:
Use up to 20 standards to establish a standard curve. Three methods for fitting a curve:
Linear fit.
Linear through zero.
Square fit.
Quantitative: Use up to 20 standards to establish a standard curve. Three methods for fitting a curve: Linear fit. Linear

Multi-wavelength Test:
You can set up to 20 wavelengths to measure a sample.
Multi-wavelength Test: You can set up to 20 wavelengths to measure a sample. Single Beam UV Visible Spectrophotometer

Wavelength Scan:
Automatically records peaks and valleys.
The quantity of the curves stored is unlimited.
Post-run manipulation and processing includes:
Re-scaling axes, curve.
Smoothing, combination, zooming, overlap.1 to 4 derivatives.
Wavelength Scan: Automatically records peaks and valleys. The quantity of the curves stored is unlimited. Post-run

Kinetics:
The Kinetics mode may be used for scanning time courses or reacting rate calculations. Abs. Vs. Time graphs are displayed.
Kinetics: The Kinetics mode may be used for scanning time courses or reacting rate calculations. Abs. Vs. Time graphs are

DNA/Protein Test:
Optional two formulas:
DNA Concentration = 62.9A260 - 36.0A280 or 49.1A260 - 75.8A230
You can also enter other wavelengths and factors to calculate.
DNA/Protein Test: Optional two formulas: DNA Concentration = 62.9A260 - 36.0A280 or 49.1A260 - 75.8A230 You can also enter
Functions:
Photometry
Absorbance, Transmittance or Energy measurements. It can display and save 200 groups of data, 5 groups per screen.
Quantitative
Standard Curve
At most, 9 standard samples can be used to establish a standard curve. The curve and its equation will be displayed on the screen simultaneously. You can measure your unknown concentration solutions by the curve.
A total of 200 curves can be saved in the Memory.
Coefficient Method
If the coefficient k & b in the formula C = k*a + b is known, you can input them directly by the button, and then test your unknown solutions.
Kinetics
This mode may be used for time course scanning or reaction rate calculations. Abs. VS Time graphs are displayed on the screen in real time. It can record 1000 data.
System Utilities
Lamp management, time & date set, obtain dark current, calibrate wavelength, default system, and some other system functions.

Accessories For Purchase

Images
Name
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Micro Cell Holder
(Beam height: 15mm)
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
8-Position Auto Cell Changer
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
4-Cell Holder for 10mm SQU.cuvette
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
4-Cell Holder for 50mm SQU.cuvette
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
4-Cell Holder for 100mm SQU.cuvette
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Square Cuvettes
Glass :10 mm
20 mm
30 mm
50 mm
100 mm
Square cuvettes Quartz:10 mm
20 mm
30 mm
50 mm
100 mm
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Micro cell, Quartz
(Beam height: 15mm)
100UL
200UL
500UL
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Sipper System
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Constant-Temperature System
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Constant-Temperature Sipper System
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Test Tube Holder
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Cylindrical Cell Holder
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Solid Sample Holder (Single Cell)
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Water-Jacketed Cell Holder
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
10mm Water-Jacketed
4-Cell Holder
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Milas Deuterium
Lamp
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Halogen Lamp(Philips)
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Halogen Lamp(Philips)
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Halogen Lamp(Osram)
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Self Masking Cont. Flowthrough G.Cell
(Beam height: 15mm)
5mm
10mm
20mm
30mm
Self Masking Cont. Flowthrough Q. Cell
(Beam height: 15mm)
5mm
10mm
20mm
30mm
ImagesNameMicro Cell Holder(Beam height: 15mm)8-Position Auto Cell Changer4-Cell Holder for 10mm SQU.cuvette4-Cell Holder
Thermal Printer





Request Quote
Name*:
Email*:
I am *: Distributor End User Others
WhatsApp :
Product :
Subject :
Message :