Nano Spectrophotometer BGH1S1

Micro-spectrophotometer
  • Sea, Air, Door to Door Shipping
  • 1 Year Warranty
  • US & European Standards



Nano Spectrophotometer 200~800 nm 0.5~2.0 μL

Specifications

ModelBGH1S1
Wavelength range200~800 nm
Minimum sample size0.5~2.0 μL
Path length0.2 mm 1.0 mm
Light sourceXenon flash lamp
Detector type2048-linear CCD array
Wavelength accuracy1 nm
Spectral resolution≤ 3 nm
Absorbance precision0.003 Abs
Absorbance accuracy1 % (7.332 Abs at 260 nm)
Absorbance range0.04~90 A
Nucleic acid detection range2~4500 ng/μL (dsDNA)
Measurement time< 5 s
Dimension (WxDxH) mm200x250x166
Weight2.6 kg
Sample pedestal materialAluminum alloy and quartz fiber
Operating voltageDC 24 V 2 A
Operating power20 W
Standby power5 W
Software compatibilityWin 7, Win XP, Win 8
Cuvette Mode (OD600 Measurement)
- Light source/
- Wavelength range/
- Absorbance range/
Fluorometer Mode
- Sensitivity/
- Linear dynamic range/
- Repeatability/

Features

User-Friendly Software, Easy to Use
Graphical software operation, more intuitive interface, the results can be directly exported, easy to save, view and output data.
Micro-Volumes Measuring
Only 0.5 μL-2 μL sample is needed for each test. After the measurement, the samples can be recovered and the precious samples can be studied with confidence.
Long Life Light Source, Do Not Need to Warm Up
Xenon flash, life span is 10⁹ (up to 10 years). No preheating, direct use, ready to test at any time.
High Concentration Detection
The maximum concentration of the detectable sample is 15000 ng/μL, and the sample basically does not need to be diluted.
Convenient and Easy to Use
Directly point the sample on to the sample plate without dilution or cuvette. The sample concentration can be measured as 50 times of the conventional uv-visible photometer, and the result can be directly output as the sample concentration.
Fast Detection
No dilution or cuvette needed in the detection process; 5 s can complete the test and display the result.
Single Machine Operation, Convenient and Efficient


It is a micro-spectrophotometer with full wavelength (200-800 nm).
The detectable sample is 50 times that of conventional UV / Vis spectrophotometer, and maximum detection concentration up to 4500 ng/μL (dsDNA).
High resolution CCD array detector, 5 s can complete the detection, display the results.
Long life pulse xenon lamp light source.
The need to connect PC computers to run detection, data saving, printing, sorting are very convenient.

More Info

Fluorescence Detection Mode (Can Be Customized)
Model
Nano500U (optional)
Nano500 (standard)
Nano500G (optional)
Nano500R (optional)
Channel
UV
Blue
Green
Red
Excitation wavelength
365±20 nm
460±20 nm
525±20 nm
625±20 nm
Emission wavelength
420-480 nm (60 nm)
525-570 nm (45 nm)
575-640 nm (65 nm)
670-725 nm (55 nm)

Fluorescence Detection Mode - Specification
Parameter
Specification
Light source
LED
Dynamic range
5 orders of magnitude
Linearity
R≥0.995
Detector
Photodiode
Repeatability
≤1.5 %
Stability
≤1.5 %
Sensitivity
dsDNA: 0.5 pg/μL
Measurement speed
3 s (once)

Applications

Different Fluorescence Channels: Nano Spectrophotometer 200~800 nm 0.5~2.0 μL
Different Fluorescence Channels:

UV Channel:
Excitation wavelength: 365±20 nm
Common reagent: Hoechst 33258, 4-MU, EnzChek Caspase
Nucleic acid quantification, plant GUS reporter gene detection, apoptosis detection

Blue Channel:
Excitation wavelength: 460±20 nm
Common reagent: PicoGreen, oligreen, RiboGreen, GFP, Protein, Fluorescein
dsDNA, ssDNA, GFP, gene detection, fluorescein detection, protein quantification.

Green Channel:
Excitation wavelength: 525±20 nm
Common reagent: Rhodamine, Cy3, RFP Vybrant Cytotoxicity
Rhodamine detection, Cy-3 fluorescence labeling detection, RFP gene detection, cytotoxicity detection.

Red Channel:
Excitation wavelength: 625±20 nm
Common reagent: Cy5, Quant-iT RNA
Cy-5 fluorescence labeling detection, RNA quantification




Request Quote
Name*:
Email*:
I am *: Distributor End User Others
WhatsApp :
Product :
Subject :
Message :