Nano Spectrophotometer BEP1K1
Nano Spectrophotometer- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards

Specifications
| Model | BEP1K1 |
| Minimum Sample Size | 1-2.0 μl |
| Wavelength Range | 260nm, 280nm |
| Absorbance Range | 0.02-80A |
| Absorbance Accuracy | 1% (7.332Abs at 260nm) |
| Absorbance Precision | 0.005Abs |
| Photometric Repeatability | <1.5% |
| Path Length | 0.5 mm |
| Light Source | UV LED |
| Detector | UV-silicon photocell |
| Detection Range | Nucleic acid up to 10-4000ng/ul (dsDNA) |
| Measurement Time | < 8s |
| OD600 nm Measurement | |
| OD600 nm Measurement - Wavelength Range | 600±8 nm |
| OD600 nm Measurement - Absorbance Range | 0-4A |
| Software | USB |
| Software Compatibility | Android System |
| Sample Pedestal Material | Aluminium alloy and Quartz fiber |
| Dimension (W/D/H) | 210x280x181 mm |
| Weight (Net/Gross) | 3.5 kg |
| Standby Power | 5 W |
| Power | 25 W |
| Power Supply | 24V DC |
Features
1. User-friendly software, easy to useGraphical software operation, more intuitive interface, the results can be directly exported, easy to save, view and output data.
2. Micro-volumes measuring
Only 0.5 μL-2 μL sample is needed for each test. After the measurement, the samples can be recovered and precious samples can be studied with confidence.
3. Fast detection
No dilution or cuvette needed in the detection process; 5 s can complete the test and display the result.
4. Long life light source, do not need to warm up
Xenon flash, life span is 10⁸ (up to 10 years). No preheating, direct use, ready to test in any time.
5. High concentration detection
The maximum concentration of the detectable sample is 15000 ng/μL ( dsDNA as an example), and the sample basically does not need to be diluted.
6. Convenient and easy to use
Directly point the sample on to the sample plate without dilution or cuvette. The sample concentration can be measured as 50 times of the conventional uv-visible photometer, and the result can be directly output as the sample concentration.
7. Single machine operation, convenient and efficient
8. It is a full-wavelength micro-spectrophotometer, and it is a fixed wavelength ultra-micro nucleic acid analyzer.
Advantages:
It is a fixed wavelength (260 nm, 280 nm, 365 nm) ultra-micro nucleic acid analyzer, which is used for routine analysis of micro sample testing and is a supplement to the full wavelength instruments
Android system, 7-inch capacitive touch screen, no computer connection required.
LED light source, long life component.
It is mainly used to detect the concentration and purity of nucleic acid, and to detect the concentration of nucleic acid at 260 nm, the concentration of protein at 280 nm. The 260 / 280 ratio is used to measure the purity.
Newly designed OD600 optical path detection system, new cuvette mode, convenient for the concentration detection of bacteria, microorganisms and other culture solutions.
The test data is transferred to the computer via USB for easy sorting and analysis.
Easy-to-use data printing options, can print the report directly through the built-in printer.