Multi-parameter Analyzer BEP1P1 (BMET-1301)
Portable Ph/orp Meter- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards

Specifications
| Model | BEP1P1 |
| pH Measuring Range | -2 ~ 20 pH |
| Temperature Measurement Range | 0 ~ 105 °C, 32 ~ 221 °F |
| pH Resolution | 0.001, 0.01, 0.1 |
| mV Measuring Range | ± 1999.9 mV |
| Temperature Accuracy | ± 0.5 °C, ± 0.9 °F |
| pH Basic Error | ± 0.002 pH |
| Basic Error | ± 0.2 mV |
| pH Calibration Points | 1 ~ 5 points (USA, NIST, DIN, Custom) |
| Temperature Compensation | Automatic/Manual 0 ~ 100 °C, 32 ~ 212 °F |
| Storage Capacity | Stores up to 500 data sets |
| Temp Calibration Points | 1 point |
| Calibration Due Alarm | 1 ~ 31 days |
| Hold Function | Manual or Automatic endpoint detection |
| Stability Criteria | Low or High |
| mV Calibration Points | 1 point (Only for Relative mV mode) |
| Output | USB communication interface |
| Dimensions and Weight | 170 (L) x 85 (W) x 30 (H) mm |
| Weight | 300 g |
| Standard accessories | pH electrode, temperature probe, pH buffer solutions (4.01 / 7.00 / 10.01), carrying case |
| Power Supply | 3 x 1.5 V AA batteries or DC5 V power adapter |
Description
Multi-parameter Analyzer simultaneously measures Ion, Conductivity, Dissolved Oxygen, Temperature that otherwise requires four different meters. With the appropriate probes installed, it can also simultaneously measure several or one parameters.Features
pH1 to 5 points push-button calibration with auto-buffer recognition
Selectable pH buffer group (USA / NIST / DIN) or using the custom calibration solutions
Automatic electrode diagnosis with pH slope and offset display
Automatic Temperature Compensation provides accurate reading over the entire range
Calibration Due Reminder prompts user to calibrate the meter regularly
ORP
1 point offset calibration allows adjusting the displayed value to a known standard
Relative and absolute millivolt modes provide the reliable ORP measurements
GENERAL
Stability indicator shows when a measurement is recognized as stable
Auto-Hold feature senses and locks the measurement endpoint
Setup menu allows setting the 9 parameters, including the pH buffer group, number of calibration points, resolution, stability criteria, auto-power off, etc
Reset feature automatically resumes all settings back to factory default options
Expanded memory stores and recalls up to 500 data sets
Stored readings can be transferred into the computer by USB communication interface
Multi-mode power scheme (battery, power adapter or USB port) ensures that use the meter smoothly.