Magnetic Stirrer BFL1BB2 (BMGS-107)

Magnetic Stirrer
  • Sea, Air, Door to Door Shipping
  • 1 Year Warranty
  • US & European Standards



Magnetic Stirrer Ø135mm (5 inch) Nylon+GF

Specifications

ModelBFL1BB2
Work plate DimensionØ135mm (5 inch)
Work plate materialNylon+GF
Motor typeBrushless DC motor
Stirring positions1
Max. stirring quantity [H2O]3L
Max. magnetic bar [length]50mm
Speed range0-1500rpm
Speed displayScale
Protection classIP42
Motor output Power3W
Power10W
Voltage, Frequency100-240V, 50/60Hz
Dimension [WxDxH]150x260x80mm
Weight1.8kg
Permissible ambient temperature and humidity5-40°C, 80%RH

Features

Digital speed control within the range of 0-1500 rpm
Maximum stirring quantity of H₂O at 3L

Operating Manual

Download


Preface
Service
Warranty
1. Safety Instructions
2. Proper use
3. Inspection
    3.1 Receiving Inspection
    3.2 Listing of Items
4. Control
    4.1 Control elements
    4.2 Display
5. Trial run
6. Function: Heating (Digital hotplate model)
    6.1 Working with external temperature sensor
    6.2 Residual heat warning(HOT)
7. Stirring
8. Faults
9. Maintenance and Cleaning
10. Associated standards and regulations
11. Specifications

Preface

Welcome to the " BlueSpin (Hotplate) Magnetic Stirrer ". Users should read this Manual carefully, follow the instructions and procedures, and be aware of all the cautions when using this instrument.

Service

When help needed, you can always contact the Service Department of manufacturer for technical support in the following ways:

Please provide the customer care representative with the following information:

• Serial number( on the rear panel)

• Certification

• Description of problem (i.e., hardware or software)

• Your contact information

Warranty

This instrument is warranted to be free from defects in materials and workmanship under normal use and service, for a period of 24 months from the date of invoice. The warranty is extended only to the original purchaser. It s hall not apply to any product or parts which have been damaged on account of improper installation, improper connections, misuse, accident or abnormal conditions of operation.

For claims under the warranty please contact your local supplier. You may also send the instrument directly to manufacturer, enclosing the invoice copy and by giving reasons for the claim.

1. Safety Instructions

BFL1BB2

Warning!

Read the operating instructions carefully before use.

Ensure that only trained staff works with the instrument.

BFL1BB2

Risk of burn!

Caution when touch the housing parts and the hotplate which can reach temperature of 280 °C .

Pay attention to the residual heat after switching off.

BFL1BB2

Protective ground contact!

Make sure that socket must be grounded (protective ground contact) before use.

Table 1

When working wear personal safety guards to avoid the risk from:

- Splashing and evaporation of liquids

- Release of toxic or combustible gases

Set up the instrument in a spacious are on a stable, clean, non-slip, dry and fireproof surface. Do not operate the instrument in explosive atmospheres, with hazardous substances or under water.

Gradually increase the speed, reduce the speed if:

- Stirring bar breaks away due to high speed

- The instrument is not running smoothly, or container moves on the base plate

Temperature must always be set at least 50 °C lower than the fire point of the media used.

Be aware of hazards due to:

- Flammable materials or media with a low boiling temperature

- Overfilling of media

- Unsafe container

Process pathogenic materials only in closed vessels.

Check the instrument and accessories prior to each use. Do not use damaged components. Safe operation is only guaranteed with the accessories described in the "Accessories " chapter. Accessories must be securely attached to the device and can not come off by themselves. Always disconnect the plug before fitting accessories.

When the external temperature sensor needed, the tip of the measuring sensor must be at least 5-10 mm from vessel bottom and wall.

The instrument can only be disconnected from the main power supply by pulling out the main or the connector plug.

The voltage stated on the label must correspond to the main power supply.

Ensure that the main power supply cable does not touch the hotplate. Do not cover the device.

The instrument may only be opened by experts.

Keep away from high magnetic field.

Do not use this instrument in an explosive environment; This instrument has no explosion-proof function.

2. Proper use

The instrument is designed for mixing and/or heating liquids in schools, laboratories or factories.

Observe the minimum distances between the devices, between the device and the wall and above the assembly (min. 100 mm)

Tags:, Description:, Attributes-End, Welcome to the " BlueSpin (Hotplate) Magnetic Stirrer ". Users should read this Manual

Figure 1

This device is not suitable for using in residential areas or other constraints mentioned in Chapter 1.

3. Inspection

3.1 Receiving Inspection

Unpack the equipment carefully and check for any damages which may have arisen during transport. Please contact manufacturer/supplier for technical support.

BFL1BB2 Note:

If there is any apparent damage to the system, please do not plug it into the power line.

3.2 Listing of Items

The package includes the following items:

Items

Qty

Main unit

1

Power cable

1

User Manual

1

Table 2

4. Control

4.1 Control elements

Tags:, Description:, Attributes-End, Welcome to the " BlueSpin (Hotplate) Magnetic Stirrer ". Users should read this Manual

Figure 2

LED Digital Hotplate Magnetic Stirrer

Tags:, Description:, Attributes-End, Welcome to the " BlueSpin (Hotplate) Magnetic Stirrer ". Users should read this Manual

Figure 3

LED Digital Magnetic Stirrer

Tags:, Description:, Attributes-End, Welcome to the " BlueSpin (Hotplate) Magnetic Stirrer ". Users should read this Manual

Figure 4

Classic Magnetic Stirrer

Tags:, Description:, Attributes-End, Welcome to the " BlueSpin (Hotplate) Magnetic Stirrer ". Users should read this Manual

Figure 5

Items

Descriptions

Digital

hotplate

model

Temperature Control Knob

Heat

Set the temperature parameters. The function "heating" is switched ON or OFF via push ON/OFF knob.

Speed

Control Knob

Stir

Set the rotary speed. The function "Stirring" is switched ON or OFF via push ON/OFF knob.

LED Display

LED displays the real working state and all settings.

Probe

When the external temperature sensor PT1000 is plugged in, probe icon is lit.

Power

Switch

Switch ON or OFF the instrument.

Digital

model

Temperature Control Knob

Stir

Set the rotary speed. The function "Stirring" is switched ON or OFF via push ON/OFF knob.

LED Display

LED displays the real working state and all settings.

Power

Switch

Switch ON or OFF the instrument.


Classic

model

Speed

Control Knob

Stir

The stirring function is switched ON by rotating the knob.

Power

Switch

Switch ON or OFF the instrument.

Table 3

4.2 Display

Table 3, Figure 6, Digital hotplate model, Table 4, Figure 7, Digital model, Table 5, Make sure the required operating

Figure 6

Digital hotplate model

Character s

Descriptions

Temperatu

When heating function was switched ON, LED displays

re display

the temperature setting value and shifts to real value in 5

area

seconds. When the heating function is switched OFF and the hotplate temperature is still above 50 ° C, LED displays "Hot", otherwise LED displays OFF.

Speed

When stirring function was switched ON, LED displays the

display

speed setting value and flashes. The setting value does

area

not flash until real speed reaches the set point.

Table 4

Table 3, Figure 6, Digital hotplate model, Table 4, Figure 7, Digital model, Table 5, Make sure the required operating

Figure 7

Digital model

Character s

Descriptions

Speed

When stirring function was switched ON, LED displays the

display

speed setting value and flashes. The setting value does

area

not flash until real speed reaches the set point.

Table 5

5. Trial run

Make sure the required operating voltage and power supply voltage match.

Ensure the socket must be properly grounded.

Plug in the power cable ,ensure the power is on and begin initializing.

Add the medium into the vessel with an appropriate stirring bar.

Place vessel on the work plate.

Set the target stirring speed and begin.

Observe the stirring bar and LED display (digital model).

Set the target temperature and start heating.

Observe the LED display (digital hotplate model).

Stop the heating and stirring functions.

If these operations above are normal, the device is ready to operate. If not, the device may be damaged during transportation, please contact manufacturer/supplier for technical support.

BFL1BB2 Warning!

Forbid to transfer the vessel when the instrument working.

6. Function: Heating (Digital hotplate model)

The device is controlled by digital temperature control technology, which has two separate safe circuits. The hotplate is kept at a constant

temperature by a digital control circuit. The hotplate temperature can also be monitored from a separate, adjustable safe circuit. The two

temperature sensors internal for temperature control are built into the hotplate. The single external PT1000 can monitor the temperature of sample.

Plug in the external PT1000.

Set the temperature via rotating the temperature control knob slowly to the target value.

When the heating function is switched on, the LED displays the temperature value on the left-hand side.

The heating function is switched on or off by pushing heating knob. The instrument automatically displays the last running speed an temperature parameters once turned on.

Generally, the LED screen cannot display the actual temperature of sample in the vessel or hotplate surface, temperature differences as following:

- Hotplate center and outer edge.

- The sample in the vessel and hotplate surface.

In order to ensure the accuracy of the temperature inside the container, please use the external temperature sensor PT1000.

6.1 Working with external temperature sensor

Table 3, Figure 6, Digital hotplate model, Table 4, Figure 7, Digital model, Table 5, Make sure the required operating

Figure 8

The external temperature sensor PT1000 is the manufacturer ' s standard accessory. When PT1000 sensor is connected and rotate the temperature control knob, LED displays the temperature setting value and shifts to real value in 5 seconds. Safe circuit controls hotplate temperature under 320 ° C. Comparing with the temperature control of the hotplate, the external temperature sensor can control the medium 's temperature more precise. The heating function will be stopped automatically under abnormal conditions. Please operate follow the instructions below:

l Switch OFF the instrument.

l Ensure the external temperature sensor is inserted in the media heated.

l Switch ON the instrument and run heating function.

If the heating function does not work, please contact manufacturer/supplier for technical support.

6.2 Residual heat warning(HOT)

In order to prevent the risk of burns from a hotplate, digital hotplate has a residual heat warning function. When the heating function is switched off and the heating plate temperature is still above 50 °C, "Hot" will flash to warn that there is a hazard of burns from the hotplate. When the unit is powered off, the LED screen displays the temperature of hotplate and Hot in turn. When the hotplate temperature drops to below 50 ° C, the unit will automatically switch off. If users want to turn off the LED immediately, just pull out the plug directly. When the plug is pulled out, the residual heat warning function cannot be run.

7. Stirring

The function "stirring" of LED digital model is switched on or off via pushing on/off speed control knob. The speed range of 200 to 1500 rpm and in steps of 10 rpm.

The function "stirring" of classic model is switched on or off via rotating speed control knob. The speed range of 200 to 1500 rpm.

8. Faults

Instruments can 't be power ON

- Check whether the power line is unplugged

- Check whether the fuse is broken or loose

Fault in power ON self test

- Switch OFF the unit, then switch ON and reset the instruments to factory default setting.

Stir speed cannot reach set point

- Excessive medium viscosity may cause abnormal speed reduction of the motor

Unit cannot be powered off when switched off.

- Check if the residual heat warning function is still ON and hotplate temperature is above 50 °C (the LED screen still work and " Hot " flash).

If these faults are not resolved, please contact dealer/ suppler.

9. Maintenance and Cleaning

Proper maintenance can keep instruments working properly and lengthen its lifetime.

Do not spray cleanser into the instrument when cleaning.

Unplug the power line when cleaning.

Only use recommended cleansers:

Dyes

Isopropyl alcohol

Construction materials

Water containing tenside /Isopropyl alcohol

Cosmetics

Water containing tenside /Isopropyl alcohol

Foodstuffs

Water containing tenside

Fuels

Water containing tenside

Table 6


Before using other method for cleaning or decontamination, the user must ascertain with the manufacturer that this method will not harm the instrument. Wear the proper protective gloves during cleaning of

the instrument.

BFL1BB2 Note:

Electronic device cannot clean with cleanser.

If you require maintenance service, must be cleaned the instrument in advance to avoid pollution of hazardous substances, and to send back into original packing.

If the instrument will not use for a long time, please switch off and place in a dry, clean, room temperature and stable location.

10. Associated standards and regulations

Construction in accordance with the following Safety standards:

EN 61010-1

UL 61010-1

CAN/CSA C22.2(1010-1) EN 61010-2-10


Construction in accordance with the following EMC standards:

EN 61326-1


Associated EU guidelines:

EMC-guidelines: 89/336/EWG

Instrument guidelines: 73/023/EWG


Changes or modifications not expressly approved by the party

responsible for compliance could void the user's authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.


These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

11. Specifications

Items

Specifications

Digital (heating) model

Classic

model

Voltage [VAC]

*100~120/200~240 100~240

Frequency [Hz]

50/60

50/60

Power [W]

*515/15

10

Stirring point position quantity

1

1

Max. stirring quantity (H2O) [l]

3

3

Max. magnetic bar [LxØ,mm]

50

50

Motor type

Brushless DC motor

Max. power input of motor [W]

5

5

Max. power output of motor [W]

3

3

Speed range [rpm]

200 - 1500, increment:10

0 - 1500

Rotary speed display

LED

Scale

Plate material

*Ceramic coated/Plastic

Dimensions of workplate (mm)

φ135

φ135

*Heating power [W]

500

-

*Temperature range [ °C]

RT+5-280, increment:1

-

*Temperature display [°C]

LED

-

*Temperature display accuracy [ °C]

±1

-

*The safe temperature of hotplate [°C]

320

-

*Temperature sensor in medium

PT1000

-

*Control accuracy of heating temperature with temperature sensor [°C]

±0.2

-

*Residual heat warning

50°C

-

Dimensions (mm)

*260 x150 x100

260 x150 x80

Weight [kg]

1.8

1.8

Permitted ambient temperature [ °C]

5-40

Permitted relative humidity

80%

Protection class acc. To DIN 60529 *Hotplate model

IP21

Table 7







Request Quote
Name*:
Email*:
I am *: Distributor End User Others
WhatsApp :
Product :
Subject :
Message :