Infant Incubator BEM2CD2

Infant Incubator
  • Sea, Air, Door to Door Shipping
  • 1 Year Warranty
  • US & European Standards



Infant Incubator AC220V, 50/60Hz (Standard) 1320VA; AC110V, 60Hz (Optional) 950*645*(1250~1450)mm

Specifications

ModelBEM2CD2
Power SupplyAC220V, 50/60Hz (Standard) 1320VA; AC110V, 60Hz (Optional)
Size(L*W*H)950*645*(1250~1450)mm
Maximum Heater Output Power(220VAC)Air Chamber Heater: 330W; Water Tank Heater: 155W
Auxiliary Network Power OutputAC220V/50Hz, both maximum permissible currents are 220V 1.5A
Heater Indication0~100%, 10% increasing amount
Temperature Control ModeBed temperature mode; The skin temperature mode
Bed Temperature Control Temperature Range25.0~37.0°C; 37.1~39.0°C (Span mode)
Skin Temperature Control Range34.0~37.0°C; 37.1~38.0°C (Span mode)
Skin Temperature Sensor Display Range5.0~65.0°C
Heating Time≤50min
Temperature Variability≤0.5°C
Temperature Uniformity (Mattress in horizontal position)≤0.8°C
Temperature Uniformity (Mattress in tilted position)≤1.0°C
Difference Between Average Incubator Temperature and Control Temperature≤1.5°C
Skin Temperature Sensor Accuracy±0.3°C
The running time of the tank after it is filled with distilled waterHumidity below 70%RH, at least 24h
Water Tank Capacity1500ml
Humidity Display Range0%RH~99%RH
Humidity Control RangeCAH%RH~90%RH (1% per adjustment)
Humidity Control Accuracy±10%
Oxygen Concentration Display Range0%~99%
Oxygen Concentration Display Resolution1%
Oxygen Concentration Control Accuracy±5% oxygen volume concentration
Oxygen Concentration Setting Range21%~60% (1% per adjustment)
Oxygen Sensor Service LifeThe maximum use time is 10000h at 100% oxygen concentration
Transport Storage Temperature-20°C~+55°C
Atmospheric Pressure Range500hPa~1060hPa
Relative Humidity (≤)≤93%RH
Packing Size/Gross Weight1150*800*1600mm, 190kg
Relative Humidity (30%-75%)30%RH~75%RH
The Environment Temperature+20°C~+30°C
Service Altitude≤2000m
Over Voltage CategoryII
Pollution Levels2
Ambient Air Velocity≤0.3m/s
Environmental Noise In Incubator Baby CompartmentNo more than 55dB(A) at stable temperature
Carbon Dioxide Concentration In The Infant CompartmentA mixture of 4% carbon dioxide and air was fed into an 8mm diameter tube ... concentration was less than 0.5% after stabilization
The velocity of air flow over a baby's mattress≤0.35m/s
General AlarmPower failure alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, water tank placement error alarm, water shortage alarm
The System AlarmMcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, analog-to-digital conversion chip 2544 failure alarm, analog-to-digital conversion chip 2548 failure alarm, over temperature alarm, temperature heating system failure, humidity heating system failure
Temp. ControlBed/Skin Temperature
DisplayLCD
Bed Temp. Control Range25°C~39°C
Skin Temp. Control Range34°C~38°C
Humidity Control RangeCAH%~99%RH
Oxygen Control Range/
CabinetYes
Height Adjustable/

Description

Infant incubator is one of the important equipment used in medical institutions. It is mainly used for constant temperature cultivation, temperature resuscitation, oxygen delivery, rescue, hospitalization and observation of sick infants and premature infants. It is used in hospitals, confinement centers, neonatology, etc.

Features

1. LCD display.
2. Double control modes of bed temperature and skin temperature.
3. Double-layer thermostatic cover, automatic air curtain device.
4. Humidity control function.
5. Air&Oxygen blender.
6. Oxygen supply system.
7. Baby cot is infinitely adjustable.
8. 24 kinds of sound and light alarm, comprehensive protection of baby safety.




Request Quote
Name*:
Email*:
I am *: Distributor End User Others
WhatsApp :
Product :
Subject :
Message :