Handheld Spectrophotometer Reflectance: D/8 (Diffuse illumination, 8° acceptance) SCI & SCE; Exclude UV CIE No.15, GB/T Handheld Spectrophotometer Reflectance: D/8 (Diffuse illumination, 8° acceptance) SCI & SCE; Exclude UV CIE No.15, GB/T Handheld Spectrophotometer Reflectance: D/8 (Diffuse illumination, 8° acceptance) SCI & SCE; Exclude UV CIE No.15, GB/T Handheld Spectrophotometer Reflectance: D/8 (Diffuse illumination, 8° acceptance) SCI & SCE; Exclude UV CIE No.15, GB/T Handheld Spectrophotometer Reflectance: D/8 (Diffuse illumination, 8° acceptance) SCI & SCE; Exclude UV CIE No.15, GB/T

Specifications

ModelBJH1B3
Optical GeometryReflectance: D/8 (Diffuse illumination, 8° acceptance) SCI & SCE; Exclude UV
Standards CompliantCIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO77241, ASTM E1164, DIN5033 Teil7
Integrating Sphere SizeΦ40 mm
Light SourceCombined full spectrum LED light source
Spectrophotometric ModeFlat Grating
SensorSilicon photodiode array (double row 40 groups)
Wavelength Range400-700 nm
Wavelength Interval10 nm
Semiband Width10 nm
Measured Reflectance Range0-200%
Measurement ApertureCustomized one aperture: MAV: φ8 mm/Φ10 mm; SAV: φ4 mm/φ5 mm
Specular ComponentSCI & SCE
Color SpacesCIE LAB, XYZ, Yxy, LCh, CIE LUV, sRGB, βxy, Munsell (C/2)
Color difference formulasΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00
Other Colorimetric IndexWI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), Staining Fastness, Color Fastness, Color Strength, Opacity, 8° Glossiness
Observer2° / 10°
IlluminantD65, A, C, D50, F2 (CWF), F7 (DLF), F10 (TPL5), F11 (TL84), F12 (TL83/U30)
Displayed Data (results)Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
Measurement TimeAbout 1.5 s (simultaneous measurement SCI/SCE about 3.2 s)
RepeatabilitySpectral reflectance: MAV/SCI, Standard deviation within 0.1% (400-700 nm: within 0.20%). Chromaticity value: MAV/SCI, within ΔE*ab 0.04 (30x white plate at 5 s intervals after calibration)
Interinstrument ErrorMAV/SCI within ΔE*ab0.2 (Average for 12 BCRA Series II color tiles)
Measurement ModeSingle measurement, average measurement (2-99 times)
Locating MethodCamera locating, stabilizer cross position
Dimension (LxWxH)129 x 76 x 217 mm
WeightApprox. 600 g
Battery3.7V, 5000mAh Li-ion; 6000 measurements within 8 hours
Illuminant Life Span5 years; more than 3 million times measurements
Screen/Display3.5-inch TFT color LCD; capacitive touch screen
Data PortUSB
Data storageStandard: 1000 pcs; Sample: 20,000 pcs (one PCS can include both SCI & SCE)
LanguagesSimplified Chinese, English, Traditional Chinese
Operating EnvironmentTemperature: 0-40 °C; Humidity: 0-85% (no condensation); Altitude < 2000 m
Storage EnvironmentTemperature: -20-50 °C; Humidity: 0-85% (no condensation)
Standard AccessoriesPower Adapter; User Guide; PC Software (download from office website); USB cable; White & Black Calibration Cavity; Protective Cover; Wrist strap; One aperture (8 mm or 4 mm)
Optional AccessoriesMicro Printer; Powder test box

Description

Designed for fast and precise color measurements of surfaces, spectrophotometer can easily achieve precise color transmission, and can also serve as a detection device for precise color matching systems, which is widely used in the quality control of color difference for various products. Equipped with highend color management software, can be connected to a computer for more functional extensions.
Dual optical path system
Custom 8mm or 4mm aperture
SCI and SCE spectrum
3.5inch TFT true color screen
Storage 20000 test data
Excellent interstation consistency dE*ab<0.2; Ultrahigh repeatability accuracy: dE*ab Better than + or 0.04
Color management software

Features

D / 8 geometric optical structure
Adopt combined LED light source with high life and low power consumption;
Customized one 8mm or 4mm aperture ( the flat/ tip measuring aperture can be switched easily, which is suitable for more tested sample)
Dual optical path system, the optical resolution in the visible range is less than 10nm, which can measure the SCI and SCE spectrum of the sample at the same time;
Accurate spectrum and lab data, used for color matching and accurate color transmission;
High hardware configuration: 3.5inch TFT true color screen, capacitive touch screen, 1000 line blazed grating, silicon photocell array detector with large photosensitive area, etc;
USB interface,convenient for expansion of various functions;
Super dirt resistant and stable standard white calibration board; Calibrated white tile (artificial diamond zirconium material)
Mohs hardness: 9
Spectral reflectance:>90%
No discoloration due to changes in temperature and humidity
No discoloration from oxidation
Ultrahigh strength and resistant to scratching
Large capacity storage space, which can store more than 20000 pieces of test data
2/10 standard observer's angle, multiple light source modes, multiple surface color systems, meet various standards of chromaticity indicators, and the needs of various customers for color measurement;
Camera locating position and Stabilizer cross measurement position;
PC software has powerful function expansion;




Request Quote
Name*:
Email*:
I am *: Distributor End User Others
WhatsApp :
Product :
Subject :
Message :