Double Beam UV Visible Spectrophotometer
Double Beam UV Visible Spectrophotometer BHV1E2



Double Beam UV Visible Spectrophotometer BHV1E2
Spectrophotometer, Double Beam Spectrophotometer- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards

Specifications
Model | BHV1E2 |
Wavelength Range | 190-1100 nm |
Spectral Bandwidth | 1 nm |
Optical System | Double Beam, Grating 1200 lines/mm |
Wavelength Accuracy | ±0.3 nm |
Wavelength Repeatability | 0.2 nm |
Scan Speed | Hi, MED., LOW., MAX. 3000 nm/min |
Photometric Accuracy | ±0.3 %T or ±0.003A @1A |
Photometric Range | 0-200%T,-0.3-3A |
Stray Light | 0.04%T @220 nm, 360 nm |
Stability | 0.0003 A/h @500 nm |
Display | 5 inches LCD (320x240 dots) |
Baseline Flatness | ±0.0005 A |
Standard Cell Holder | Standard 10 mm single cell holder (2 pcs) |
Sample Compartment | Standard 10 mm pathlength cuvette |
Light Source | Tungsten & Deuterium lamp (Pre-aligned) |
USB Type A Port | USB Type A for USB memory device (Right side) |
USB Type B Port | USB Type B for optional computer connectivity (Back) |
Output Parallel Port | Parallel port for printer |
Power Requirement | AC 110/220 V 50/60 Hz |
Dimensions (LxWxH) | 589x428x200 mm |
Weight | 22 kg |
Description
It is an advanced double beam design consisting of 3 models.The two detectors measure sample and reference respectively and simultaneously for optimizing measurement accuracy.
They provide excellent performance for measurements in the range of 190 to 1100 nm, the memory is 32K. They are suitable for pharmaceutical, biochemical and clinical lab applications as well as routine applications such as quantitative analysis, kinetics, wavelength scan, multiple components and DNA/Protein. PC Windows application software makes these instruments versatile. All instruments provide excellent performance for measurements.
Features
Fixed or variable slits (Bandwidths).For stand-alone models, all software methods are included as built-in standard; this eliminates the need of software.
Online software upgrading via the internet helps to keep it updated.
Data Download-to-PC software expands the data storage to unlimited.
The stand-alone model has a 5-inch screen and the PC model has UV-Vis Analyst software.
Data can be saved by a USB memory device directly.
Stand-alone models of UV-6 Series have the same functions as UV-3 series; see next page for details.
Brief Introduction:
All methods are included as built-in standard; this eliminates the need for software. Online software update via the internet.
The local control software includes functions such as: Photometry, Quantitative, Wavelength Scan, Kinetics, DNA/Protein, Multi-wavelength Test and System Utilities.

Standard Curve:
Up to 10 standard solutions may be used to establish a calibration equation curve. There is a choice of four methods for fitting curves through the calibration points: Linear fit, Linear fit through zero, square fit and cubic fit.

Multi-Wavelength:
Up to 10 wavelengths may be entered, allowing the measurement of multiple wavelengths on a series of samples.

Wavelength Scan:
The Wavelength Scan intervals are 0.1, 0.2, 0.5, 1, 2, 5 nm, and High, Medium and Low scan speeds are available. Scan speeds vary from 100 to 3000 nm/min. Wavelengths are scanned from high to low so that the instrument stands-by at high wavelength. This minimizes the degradation of UV sensitive samples. Precise control of filter and lamp changes means that their effects are not seen on the final scan. Post-run manipulation includes re-scaling axes, curve tracking and peak picking.

Kinetics:
This mode may be used for scanning time courses or reacting rate calculations. Abs. VS Time graphs are displayed on the screen in real time.
Wait time and measurement time up to 12 hours may be entered with time intervals of 0.5, 1, 2, 5, 10, 30 seconds and 1 min.
Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for the rate calculation. Rate is calculated using a linear regression algorithm before multiplying by the entered factor.

DNA/Protein Test:
Concentration and DNA purity are calculated by Absorbance ratios 260 nm/280 nm or 260 nm/230 nm with optional subtracted absorbance at 320 nm.
DNA Concentration = 62.9A260 - 36.0A280 or 49.1A260 - 3.48A230
Protein Concentration = 1552A260 - 757.3A280 or 183A220 - 75.8A230
Other wavelengths and factors may be entered.

UV Analyst PC-Control Software:
The PC application software offers:
Photometric Mode
Quantitative test (Standard curve)
Wavelength Scan
Kinetics
DNA/Protein
Multi-Wavelength
System Utility
The PC application software UV-Vis Analyst takes the best features of the stand-alone version plus more powerful data processing, expanded data collecting, and storage capability. It comes standard with UV3/6 series PC models and is optional to stand-alone models.
Quantitative Test (Standard curve):
Use up to 20 standards to establish a standard curve. Four methods for fitting a curve:
Linear fit.
Linear through zero.
Square fit.
Cubic fit.

Multi-wavelength:
Up to 20 wavelengths can be selected and multiple samples can be measured. (Auto cell changer is required to run multiple samples automatically)

Wavelength Scan:
Automatically record peaks and valleys. The quantity of channels is unlimited; you can simultaneously store as many as desired.
Post-run manipulation and processing includes:
Re-scaling axes, curve.
1 to 4 derivative.
Smoothing, combination, zooming, overlap.

Kinetics (Abs. VS Time):
The Kinetics mode may be used for scanning time courses or reacting rate calculations. Abs. VS Time graphs are displayed on the screen in real time. Wait time, measurement time and time intervals may be entered.
Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for the rate calculation. Rate is calculated using a linear regression algorithm before multiplying by the entered factor.

DNA/Protein:
Concentration and DNA purity are quickly and easily calculated:
Absorbance ratios 260 nm/280 nm with optional subtracted absorbance at 320 nm.
DNA Concentration = 62.9A260 - 36.0A280
Protein Concentration = 1552A260 - 757.3A280
Other wavelengths and factors may be entered.

Accessories For Purchase
images | name | og_model |
![]() | Micro Cell Holder (Beam height: 15mm) | 900240 |
![]() | 8-Position Auto Cell Changer | 900310 |
![]() | 4-Cell Holder for 10mm SQU.cuvette | 900410 |
![]() | 4-Cell Holder for 50mm SQU.cuvette | 900420 |
![]() | 4-Cell Holder for 100mm SQU.cuvette | 900430 |
![]() | Square Cuvettes Glass :10 mm | 916101 QUARTZ: 10 mm 916111 20 mm 916112 30 mm 916113 50 mm 916114 100 mm 916115 |
20 mm | 916102 | |
30 mm | 916103 | |
50 mm | 916104 | |
100 mm | 916105 | |
Square cuvettes Quartz:10 mm | 916111 | |
20 mm | 916112 | |
30 mm | 916113 | |
50 mm | 916114 | |
100 mm | 916115 | |
![]() | Micro cell, Quartz (Beam height: 15mm) 100UL | 916126 |
200UL | 916127 | |
500UL | 916123 | |
![]() | Sipper System | 900140 |
![]() | Constant-Temperature System | 900150 |
![]() | Constant-Temperature Sipper System | 900160 |
![]() | Test Tube Holder | 900530 |
![]() | Cylindrical Cell Holder | 900540 |
![]() | Solid Sample Holder (Single Cell) | 900550 |
![]() | Water-Jacketed Cell Holder | 900610 |
![]() | 10mm Water-Jacketed 4-Cell Holder | 900620 |
![]() | Milas Deuterium Lamp | 916633 |
![]() | Halogen Lamp(Philips) | 6V10W: 911634 |
![]() | Halogen Lamp(Philips) | 12V20W: 916634 |
![]() | Halogen Lamp(Osram) | 961634 |
![]() | Self Masking Cont. Flowthrough G.Cell (Beam height: 15mm) 5mm | 916135 |
10mm | 916136 | |
20mm | 916137 | |
30mm | 916138 | |
Self Masking Cont. Flowthrough Q. Cell (Beam height: 15mm) 5mm | 916145 | |
10mm | 916146 | |
20mm | 916147 | |
30mm | 916148 | |
![]() | Thermal Printer | 920910 |