Colorimeter BHJ1B1 (BDSC-106)
Differential Scanning Calorimeter- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards

Specifications
| Model | BHJ1B1 |
| Temperature range | Room temperature ~ 600°C, air cooling |
| Temperature resolution | 0.01°C |
| Temperature fluctuation | ±0.01°C |
| Temperature repeatability | ±0.1°C |
| Heating rate | 0.1~100°C/min |
| Constant temperature time | Program setting ≤ 24h |
| Temperature control mode | Heating, constant temperature, cooling (full automatic program control) |
| DSC range | 0 ~ ±600mW |
| DSC resolution | 0.01uW |
| DSC accuracy | 0.001mW |
| Working power supply | AC220V 50Hz or customized |
| Atmosphere control gas | Nitrogen, oxygen (instrument automatic switch) |
| Gas flow | 0~300mL/min |
| Gas pressure | 0.3MPa |
| Display mode | 24 bit color, 7 inch LCD touch screen display |
| Data interface | Standard USB interface |
| Parameter standard | With reference materials (indium, tin), users can adjust the temperature by themselves |
| Upper computer | Three-in-one operation software (also suitable for thermogravimetry and synchronous instruments) |
| Thermocouples | Several groups: one for sample, one for furnace body, and one for internal environment temperature |
Description
DSC is the company's highest precision differential. The sensor is made of importede-couple with high sensitivity.Signal acquisition circuit shielding protection, strong
anti-interference, high baseline stability.
The DSC is a touch screen type, which can be used for glass transition temperature test,
phase transition test, melting and enthalpy test, product stability and oxidation induction
period test.Wide range of application.
Features
1.Industrial level 7-inch touch screen, display information rich.2. New metal furnace structure, better baseline and higher precision.Indirect conduction mode is adopted in heating, which has high uniformity and stability, and reduces pulse radiation, which is better than traditional heating mode.
3. USB communication interface, strong versatility, reliable communication, support self
recovery connection function.
4. Automatic switching of two-way atmosphere flow, fast switching speed and short stable time.At the same time, a protective gas input is added.
5. The software is simple and easy to operate.

Furnace structure
Melting point, heat enthalpy, phase change temperature analysis :

Glass analysis:

Initial melting point, final melting point analysis:

Analysis of two or more section lifting temperatures:

Test report:

Accessory: