Chromatography BHB1C1
Gas Chromatography- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards

Specifications
| Model | BHB1C1 |
| Column Oven | |
| - Inner volume | 22L |
| - Temperature range | 5°C - 400°C at room temperature |
| - Temperature control accuracy | ±0.1°C |
| - Heating rate | 0.1 - 60°C / min |
| - The order of heating of the program | 9 |
| - Program temperature repeatability | ≤2% |
| - Cooling method | after the door |
| - Cooling rate | ≤10 mins (250°C - 50°C) |
| Sampler | |
| - Temperature control range | room temperature 7°C - 420°C |
| - Temperature control mode | independent temperature control |
| - Carrier gas flow control mode | constant pressure |
| - Number of simultaneous installations | up to 3 |
| - Injection unit type | packed column, shunt |
| - Split ratio | display |
| - Pre column pressure range | 0 - 400 kPa |
| - Pre column pressure control accuracy | Pre column pressure control accuracy: 0.1 kPa |
| - Flow setting range | H2O-200 ml/min, N2O-150 ml/min |
| - FID, TCD | optional one |
| Detector | |
| - Temperature control range | room temperature 7°C - 420°C |
| - Number of simultaneous installations | up to 2 |
| - Ignition function | automatic |
| - Detector | Hydrogen flame ionization detector (FID) |
| - Detection limit: | ≤3x10⁻¹² g/s (n-hexadecane) |
| - Baseline noise | ≤5x10⁻¹⁴ A |
| - Baseline drift | ≤6x10⁻¹³ A |
| - Dynamic range | 10⁷ |
| - RSD | ≤3% |
| - Sensitivity | 5000 mV·ml/mg (n-hexadecane) |
| Thermal Conductivity Detector (TCD) | |
| - Baseline noise | ≤0.05 mV |
| - Baseline drift | ≤0.15 mV / 30 min |
| - Dynamic range | 10⁵ |
| - Power supply voltage | 220V ±22V, 50Hz ±0.5Hz |
| Power | Power: 3000W |
Features
The host uses a 7-inch color touch screen, electronic display gas flow and pressure values.Computer anti-control (need to choose PC-side anti-control software) and the host touch screen to achieve synchronous two-way control.
Multi-core, 32-bit embedded hardware system to ensure reliable operation of the instrument.
One key to start a function.
Extensible synchronous external triggering function can be initiated by external signals (autosampler, thermal analyzer, etc.) at the same time to start the host and workstation.
Has a perfect system self-test function and automatic fault recognition.
Extended interface with 8 external events, which can be equipped with various function control valves and operate according to their own timing.
20 sets of sample test mode memory functions.
RS232 communication port.