Atomic Absorption Spectrophotometer BJN1G1 (BAAS-606)

Atomic Absorption Spectrophotometer
  • Sea, Air, Door to Door Shipping
  • 1 Year Warranty
  • US & European Standards



Atomic Absorption Spectrophotometer 8 lamps automatic turret, automatic alignment 110/220 V (+5% ~ -10%), 60/50 Hz; 5000 VA

Specifications

ModelBJN1G1
Light Source8 lamps automatic turret, automatic alignment
Power Supply110/220 V (+5% ~ -10%), 60/50 Hz; 5000 VA
Lamp CurrentPulsed power supply
Optical SystemLarge 1800 /mm grating ruling, full closed optical system
Wavelength Range185 - 900 nm. Automatically peak find, a key optical optimization function
Wavelength Accuracy± 0.15 nm
Wavelength Repeatability< 0.01 nm
Spectral Bandwidth0.1, 0.2, 0.4, 0.7, 1.0, 1.4, 2.0 nm (7 steps with automatic changeover)
Baseline Stability≤ ±0.002A/30 min (Static) ≤ ±0.004A/30min (Dynamic)
Absorbance Range0 - 4 A
Flame Analytical System
- DetectorImported photomultiplier tube
- Burner HeadFull titanium combustion head, 50 mm or 100 mm general combustion head
- Atomization ChamberPolymer explosion-proof spray chamber
- NebulizerAtomizer efficient glass atomizer, can also be customized
- Ignition TypeMicrocomputer control, automatic ignition
- Gas ControlAutomatic gas control system
- Detection Limits (Cu)0.002 μg/mL
- PrecisionRSD ≤ 0.5%
Graphite Furnace Analytical System
- Heating ModeVertical heating
- Temperature Control MethodVertical optical temperature monitoring graphite tube wall temperature
- Temperature RangeRoom temperature to 3000 °C
- The ProgramAutomatic temperature control up to 20 order
- Temperature ControlThe furnace enriched up to 20 times
- Characteristics Volume0.4 x 10 - 12 g (Cd)
- Detection Limit: Graphite Furnace Analytical System0.4 x 10 - 12 g (Cd)
- PrecisionRSD ≤ 2%
- The Cooling WaterCan choose cooling water circulation system
- SafetyThe graphite tube damage, water flow air pressure and other alarm temperature overheating protection

Description

An analytical technique used to measure the concentrations of elements in a sample. The system is incredibly sensitive and can detect down to micrograms (?g). It is performed by focusing a beam of known wavelength of ultraviolet (UV) light through a flame and into a detector.

Features

Eight lamp flame/graphite furnace integrated machine. Imported photomultiplier tube. The graphite tube damage, water flow air pressure and other alarm temperature overheating protection.

Applications

Food and Beverage Industry, Water Analysis, Clinical Research, Pharmaceutical, Mining and Geology, Environmental Monitoring, Oil and Petroleum, Forensics.