Atomic Absorption Spectrophotometer BFU1CN4

Atomic Absorption Spectrophotometer
  • Sea, Air, Door to Door Shipping
  • 1 Year Warranty
  • US & European Standards



Atomic Absorption Spectrophotometer Double Beam Czerny-Turner type, focal lengths at 350mm

Specifications

ModelBFU1CN4
Optical SystemDouble Beam
MonochromatorCzerny-Turner type, focal lengths at 350mm
GratingHolographic diffraction with 1800 lines/mm
Wavelength Range190-900 nm
SlitsAutomated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm
Wavelength Repeatability±0.05 nm
Wavelength Accuracy±0.15 nm
LampAutomated 8-lamp turret
Reading ModeT, A, C
Photometric Range0-125%, -0.1-3.00A
Static Baseline Drift (Cu)≤0.002A/30 min
Dynamic Baseline Drift (Cu)≤0.004A/15 min
Background Correction
Flame
--Characteristic Concentration≤0.035ug/ml
--Detection Limit (Cu)≤0.004ug/ml
--Repeatability (Cu)RSD≤0.5%
--Acetylene Flow ControlAuto 12-Level
--Air Assist ControlAuto 4-Level
--Ignition MethodPC control
--DetectorWide range UV sensitive photomultiplier tube
--Burner HeadTitanium 100mm burner for air/acetylene operation
--NebulizerHigh efficiency glass nebulizer
--Spray ChamberCorrosion resistant material spray chamber
-Safety ProtectionAutomatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched
Auto SamplerOptional
Graphite Furnace
--Characteristic AmountCd≤0.8pg, Cu≤20pg
--Detection Limit (Cu)Cd≤0.8pg, Cu≤5pg
--Repeatability (Cu)RSD≤2.5%
--Heating range of graphite furnaceRoom temperature-3000°C
--High power heating range1500-3000°C
--Slope and holding time1-255s
-Heating rateMaximum heating rate 2000°C/s
--Atomization heating mode
--Heating rate1 L/min
--Protective gas flow inside pipe4-speed adjustable (0, 50, 200, 250/min flow)
-Safety Protection
Auto SamplerOptional
Data Processing
--Measuring methodFlame method, Graphite furnace method, Hydride generation-Atomic absorption method, Flame emission method
-Concentration calculation methodStandard curve method (6 linear/non-linear fitting methods), Standard addition method, Interpolation method
-Repeat measurement times1-30 times, Calculate and give the average value of absorbance/concentration, standard deviation and relative standard deviation
-Report printingParameter printing, Data result printing
-Dimensions/ Weight850 x 650 x 550 mm/95kg
-Ambient Temp.10 ~ 35 °C
-Ambient Humidity≦85 %
-Power110/220V, 50/60Hz

Description

The Atomic Absorption Spectrophotometer is fully PC controlled. It can be flexibly equipped with an optional graphite furnace, auto sampler and hydride generator. Unique optical mechanical design, safe and convenient flame system, optional background correction technologies, as well as convenient functions provided by the workstation, suit your pursuit of automatic and precise test results.

Features

1. Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument.
2. Comprehensive and safe intelligent gas control module.
3. Excellent full band deuterium lamp background correction technology and high-performance self absorption double background correction.
4. Fully automatic instrument control, light source supports high-performance element lamp, and can be completed quickly with one key.
5. Original lamp position eight lamp holder 360 degree rotation design.
6. Novel atomizer and intelligent elevator.
7. Simple, professional, automatic and fully operated RG WIN AAS workstation software under MS window system.




Request Quote
Name*:
Email*:
I am *: Distributor End User Others
WhatsApp :
Product :
Subject :
Message :