Single Beam Visible Spectrophotometer BSSBV-304

Single Beam Visible Spectrophotometer BSSBV-304

  • Sea, Air, Door to Door Shipping
  • 1 Year Warranty
  • US & European Standards
Designed to conserve benchspace, our product offers the measurement range of 190-1100nm at bandwidth of 2nm. Engineered for a wide range of applications, our systems provide dependable performance and reliable results. It produces the photometric range of -0.3 to 3 A; 0-200 %T and photometric accuracy of ±0.3%T which makes it suitable for various quantitative assays.
  • Wavelength range: 320nm-1100nm
  • Optical System: 1200 lines/mm line Czerny Turner Diffraction Grating monochromator ensures high resolution, high photometric accuracy and low stray light
  • Bandwidth: 2&4nm
  • Detector: Silicon Photodiode
Instant Quote
Specification Features Applications Optional Accessories
Wavelength Range320-1100 nm
Wavelength Accuracy±0.5 nm
Wavelength Repeatability0.3 nm
Spectral Bandwidth2 nm
Photometric Range0-200 %T, -0.3 - 3 A, 0-9999 C
Photometric Accuracy±0.5 %T or ±0.004 A @ 1A
Stability±0.001 A/hr @ 500 nm
Stray Light0.05 %T @ 360 nm
Light SourceTungsten Lamp
Photometric ModeNone
Optical SystemSingle Beam , Grating 1200 lines/mm
Gross Dimension (W/D/H)470x373x187 mm
DisplayLCD
Weight (Net/Gross)12 kg
Power SupplyAC 110/220 V 50/60 Hz
  • Wavelength range: 320nm-1100nm
  • Optical System: 1200 lines/mm line Czerny Turner Diffraction Grating monochromator ensures high resolution, high photometric accuracy and low stray light
  • Bandwidth: 2&4nm
  • Detector: Silicon Photodiode
  • Measurement Range with ultra-low Stray Light: With its ultra-low stray light ≤0.05%Tis achieved on wavelength range of 320 - 1100 nm
  • Sample size: A wide range of standard cuvettes can be used based on the sensitivity or sample volume requirements.
  • Sophisticated and simplified sample analysis software: The Sample analysis software deliver scanning, fixed wavelength analysis, quantitative analysis, data collection, storage, export, and reporting.
  • With additional feature of an easy access USB port available in the unit, which enables results to be stored directly to a USB memory stick for easy transfer of data.
  • LCD display
  • Large sample compartment to accommodate 5-100mm cuvettes with holders
  • USB port and parallel port
  • Manually set wavelength
  • Automatic zero adjustment
Most suitable for quantitative determination assays and toxicological assays in environmental, industrial, pharmaceutical fields.
Accessory CodeNameDescriptionUnitLight Path (mm)
3000806007Holder4-cell holder for up to 50mm square cuvette
3000806008Holder4-cell holder for up to 100mm square cuvette
3000806009HolderLong path single cell holder for 100mm
3000806010HolderSingle cell holder for 10mm square Cuvette
3000806011HolderCylindrical cell holder(Φ16mm)
3000806019Other5° reflectance meachment attachment (minimum sample:20x20mm ;central beam height:50mm)/1pc
3000806020Lamp6v10w halogen lamp/1pc
3000806021Lamp12v20w halogen lamp (phillips)
3000806022Lamp12v20w halogen lamp (osram)
3000806023LampMilas deuterium lamp; 10v;300ma; 30w
3000806024LampDeuterium lamp/1pc
3000806025Thermo printer
3000806026Stylus printer
3000806027CuvettesSquare cuvettes; glass 10mm/4pcs
3000806028CuvettesSquare cuvettes; glass 20mm/4pcs
3000806029CuvettesSquare cuvettes; glass 30mm/4pcs
3000806030CuvettesSquare cuvettes; glass 50mm/4pcs
3000806031CuvettesSquare cuvettes; glass 100mm/4pcs
3000806032CuvettesSquare cuvettes; quartz 10mm/2pcs
3000806033CuvettesSquare cuvettes; quartz 20mm/2pcs
3001808006CuvettesSquare cuvettes; quartz 30mm/2pcs
3001808007CuvettesSquare cuvettes; quartz 50mm/2pcs
3000806035Cuvettes1000ul micro cell; central-beam height:8.5mm;15mm; 3x10x45mm; quartz/1pc
3000806036SoftwareDongles for 31.61 application software ; (UV analyst software)/1set
3000806037SoftwareSoftware (m.wave basic)/1set
3000806038SoftwareSoftware/1set
3000806039SoftwareAdvanced PC window software (m.wave professional)/1set
3000806040SoftwareSoftware (m.wave basic)/1set
3000806041HolderCell holder for micro cells; Central beam height: 15mm
3000806042USB connector lineUSB connector line (only for m.wave basic)/1pc
3000806043Quartz CuvetteCell; 100ul; 1pcs; central beam height: 15mm10
3000806044Quartz CuvetteCell; 200ul; 1pcs;central beam height:15mm10
3000806045CuvetteFlow cell; 5 mm; optical glass; 1pcs;central beam height:15mm; l5xw2xh5mm
3000806046CuvetteFlow cell; 10 mm; optical glass; 1pcs;central beam height:15mm; l10xw2xh5mm
3000806047CuvetteFlow cell; 20 mm; optical glass; 1pcs;central beam height:15mm;l20xw2xh5mm
3000806048CuvetteFlow cell; 30 mm; optical glass; 1pcs;central beam height:15mm; l30xw2xh5mm
3000806049CuvetteFlow cell; 5 mm; quartz; 1pcs; central beam height:15mm; l5xw2xh5mm
3001807006OtherA-102 peltier system; constant-temperature system; holder beam height:15mm
3000806052OtherA-100 peltier/sipper system; constant-temperature sipper system; holder beam height:15mm
3001808008Holder4-cell holder for 10mm to 50mm square cuvette
3001806009Holder4-cell holder for up to 100mm square cuvette
3000806054Holder10mm water-jacketed 4-cell holder
3000806055HolderTest tube holder(Φ8-Φ22mm)
3000806056HolderSolid sample holder(δ1.5mm-3mm; 1-position)
3000806057Silicon tubeSilicon tube; 1bag=1pair(1m+1m)/1bag
3000806060Glass cuvettesSquare cuvettes; volume:900ul2
3000806061Glass cuvettesSquare cuvettes; volume:450ul1
3000806062Quartz cuvettesSquare cuvettes; volume:1800ul/2pcs5
Request Quote
Name*:
Email*:
I am *: Distributor End User Others
WhatsApp :
Product :
Subject :
Message :