Sample Concentrator BCON-108
- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards
Concentrator refers to the amount of a substance in a defined space. Concentration is especially used for concentrating or preparing sample in batches in laboratory.
- "Wide temperature control range up to 150°C
- Equipped with an air chamber and a special adjustable stand, nitrogen blowing can be achieved
- Simple or programmed temperature control mode, making the experiment more convenient
- Compact structure, easy to use in narrow spaces
Specification
Features
Applications
Temp. Control Range | R.T.+5°C ~100°C |
Temp. Setting Range | 5 °C ~ 150 °C |
Temp. Stability @ 40 ~100 °C | ± 0.5 °C |
Temp. Stability @ 100~150 °C | ± 1 °C |
Block Temp. Uniformity @ 100 °C | ± 0.3 °C |
Block Temp. Uniformity @ 150 °C | ± 0.5 °C |
Temp. Display Accuracy | 0.1 °C |
Heating Speed | ≤ 30 min (40 °C to 150 °C ) |
Time Range | 1 min ~99 h 59 min |
Needle Plate Max. Lift Stroke | 286 mm |
Gas-in Joint Outer Diameter | Φ7 mm |
Nitrogen Pressure | ≤0.1 MPa |
Nitrogen Flow Rate | 0~10 L/min |
Needle Length | 150 mm |
Sample Capacity | 2 standard block |
Voltage | AC 220 V/AC 110 V 50 Hz/60 Hz |
Fuse | 250 V,3 A /6 A,Ф 5 × 20 |
Dimension(W × D × H) | 285 × 225 × 95 |
Net Weight(kgs) | 2.64 kgs |
Power | 400 W |
- "Wide temperature control range up to 150°C
- Equipped with an air chamber and a special adjustable stand, nitrogen blowing can be achieved
- Simple or programmed temperature control mode, making the experiment more convenient
- Compact structure, easy to use in narrow spaces
- High-definition color screen display, providing an intuitive and clear visual experience
- Real-time temperature and constant temperature countdown time
- With metal blocks, samples are protected from contamination
- The metal block is easy to replace, easy to clean and sterilize
- Built-in over-temperature protection device to keep you and experiments safe
- Temperature deviation calibration, more accurate temperature control
- Fault code display function, the system has its own fault detection function
- The buzzer sound can be turned off, making the experiment quieter
- Sliding operation and touch buttons, novel and fashionable
- The height of the air chamber can be adjusted to make it suitable for different test tubes, and the standard air needle length is 150 mm
- When concentrating toxic solvents, the entire system can be placed in a fume hood
- The heater causes the sample to be rapidly heated to the evaporation temperature, and at the same time, the gas is blown to the surface of the solution through the gas needle, which promotes the rapid evaporation of the solution and the concentration of the
- sample
- Unique patented design for air channel control system, enhances air tightness and reduces potential leakage; easy to operate, lift/press air needle to realize channel switch; the switching status of each channel is clear at a glance"
Drug screening, hormone analysis, liquid phase