Biological Microscope BMIC-702
- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards
Digital Biological Microscope is an optical microscope that is primarily designed to observes cells, tissues as well as other biological specimens. Magnification range anywhere from 10x – 1,000x or more by attaching multiple objective lenses.
- The integration of structure design to save space. The Microscope has a compensation free binocular viewing head inclined at 30°, 360° rotatable. Valid mould proof design. It can be used under the high temperature and high humidity environment.
Specification
Features
Applications
Viewing Head | Compensation Free Binocular Head Inclined at 30°, 360° rotatable |
Achromatic Objectives | 4X, 10X, 40X (Spring) ,100X (Spring, Oil) |
Eyepiece | Wide Field Eyepiece:WF10 X, (WF16 X optional) |
Stage | Double Layer Mechanical Stage Size 120x125 mm |
Focusing | Coaxial Coarse and Fine Adjustment, Focusing Range 30 mm, Focusing Interval 0.002 mm |
Condenser | Abbe NA=1.25 with Iris Diaphragm & Filter |
Illumination | LED(1 W) Lamp 220 V or 110 V, (LED 3 W lamp optional) |
Power Supply | AC110/220 V ± 10 %, 50/60 Hz |
Package Size | 450x360x240 mm |
Gross Weight | 5 kg |
- The integration of structure design to save space. The Microscope has a compensation free binocular viewing head inclined at 30°, 360° rotatable. Valid mould proof design. It can be used under the high temperature and high humidity environment.
University, Medical, Laboratory, Research, Pharmaceutical
Operating Manual for BMIC-702
Download Operating Manual PDF1. Application
2. Specification of Standard Accessories
3. Objectives
4. Total magnification
5. Structure
6. Operation Instruction
7. Maintenance
8. Full set of the instrument
1. Application
The products have high degree of standardization, beautiful appearance, and also have the feature about rational structure, easy to use, clarity of visual field and quality stability. And these products also are the general Equipment for medical, research, and teaching.2. Specification of Standard Accessories
1. EyepiecesCategory | Magnification | Diameter of view-field(mm) | Remark |
Wide field eyepiece | WF10X | ф18 | |
WF16X | ф11 |
3. Objectives
Category | Magnification | Numerical aperture | Working distance | Remark |
Achromatic objectives | 4X | 0.10 | 37.5 | |
10X | 0.25 | 7.613 | ||
40X(s) | 0.65 | 0.632 | spring | |
100X(s.oil) | 1.25 | 0.198 | Spring oil |
4. Total magnification
Objectives | Tube coefficient | Total magnification | |
Eyepiece 10X | Eyepiece 16X | ||
4X | 1X | 40X | 64X |
10X | 100X | 160X | |
40X | 400X | 640X | |
100X | 1000X | 1600X |
4. Mechanical tube length: 160mm
5. ABBE condenser, NA=1.25
6. Filter diameter: 32mm
7. Coarse/fine focal range:20mm
8. Stage size:X-Y:120*125mm
Longitudinal movement range: 70mm
Horizontal movement range: 30mm
9. lamp:LED lamp
10. power:AC input 220V
5. Structure
This series of microscopes are composed of the following main components.1. Objective lens case and Nosepiece:
Microscope objective lenses are engraved with various tags: magnification, Mechanical tube length/ Cover slip thickness. Such as: objective 40X: 40/0.65; 160/0.17 means that the magnification is 40X; Mechanical tube length is 160mm; Cover slip thickness is 0.17mm, and about the objective 100X oil, it is engraved with ‘oil’.
Nosepiece guarantees smooth rotation by quadruple revolving nosepiece.
2. Eyepiece: Using WF10X wide field eyepiece.
3.This series of microscope’s binocular Tube spacing adjustable range is 55mm-75mm
4. Stage: it can be operated much easily by coaxial knob in low position.
5. Condenser: ABBE condenser N.A. =1.25 with iris diaphragm, kosher illumination is optional.
Condenser can move up and down, and the condenser through strict assembly and calibration, and Users should not arbitrarily disassemble.
6. Course Focusing Adjustment:
Coarse/fine focal range is 20mm. and it is on the bottom of left and right side. Rotating rough hands wheel, the working stage rapid decrease or increase. About the micro hands wheel, it can make the stage move up and down fine. There is an indexing on the micro hands wheel. Every lattice is 0.002mm.
7. Base:
This is the basis of the product; there are four Rubber machine feet, to make it more Stable.
6. Operation Instruction
1. Unpacking and installation:Microscope packaging is foam and carton; host packed in plastic bags, Objective are on the transparent plastic box, Eyepiece with a plastic bag, it should be carefully when install.
2. Adjustment of the microscope:
1)Insert the eyepiece into the eyepiece tube, and screw objectives into the nosepiece in sequence of different magnification from low to high. Then put the specimen on the stage and secure it the position with tablet and move it to the center of stage.
2) Turn on the power switch and adjust the brightness form dark to bright slowly. After working, you must adjust the brightness to a little dark before you turn it off.
3)Observe the specimen from lower magnification objective firstly and move the specimen to thecenter of view field, then rotate higher magnification objective. You may use the fine focusing knob to obtain the clear image. When100X (soil) objective is used; you should fill up with cedar wood oil (without bubble) between the front of objective and the specimen surface. After working, it should be wiped with a few xylems immediately.
4) In order to obtain bright and clear image, the illumination must be adjusted. When different objective is chosen, you should adjust the iris diaphragm of the condenser and different brightness of the light.
5) When the lamp needs to replace, you should shut off the power switch and replace it after the lamp is cool. Note: The contact must be firmed, and the filament center should be adjusted.
7. Maintenance
1. Open the package carefully to avoid the damage of the lenses or accessories2. Operate correctly, and put the dust cover on the microscope after work.
3. Don’t dismantle the instrument rashly besides the replaceable lest the correct position should be breached.
4. Keep the instrument in dry and cool place and away from the pollution and corrosion.
5. Please send the instrument to the special repair shop if it goes out of order.
6. When the objectives and eyepieces won’t be used for a long time, please place them into a dry box, and put the dust cover onto the microscope.
8. Full set of the instrument
1 | Mainframe of bio-microscope | 1 set |
2 | Eyepiece: WF10X WF16X | 2 pcs of each |
3 | Tube | 1 pc |
4 | Achromatic Objective:4X,10X,40X,100X(oil) | 1pc of each |
5 | Cedar wood oil | 0.3ml/bottle |
6 | Operation Manual | 1 copy |
7 | Dust cover | 1 pc |