Laboratory High Speed Centrifuge BFH3B3

Vacuum Centrifugal Concentrator
  • Sea, Air, Door to Door Shipping
  • 1 Year Warranty
  • US & European Standards



Laboratory High Speed Centrifuge Room Temperature~+100°C ±1°C Laboratory High Speed Centrifuge Room Temperature~+100°C ±1°C

Specifications

ModelBFH3B3
Temp. RangeRoom Temperature~+100°C
Temp. Accuracy±1°C
Max. Speed2500rpm
Max. Capacity12x100ml
Timer0~99h59min
Vacuum Control Range0.1~1000mbar
Main unit withstands vacuum levels0.01mbar
Noise≤58dBA
Power0.7kw
Power supply220v,50Hz
Dimension(LxWxHmm)440*536*304mm

Features

1. High-definition LCD touch screen, simul-taneously displaying operational parameters: speed, temperature, vacuum, and running time.
2. Delayed start: after reaching a fixed speed, Start the vacuum pump to effectively prevent sample mixing.
3. Fully automatic vacuum control system, vacuum setting range0.1~1000mbar, Control accuracy 0.1mbar.
4. 1.5/2ml Rotor stacking for simultaneous use; rotor replacement without tools.
5. Programmable with temperature and pressure settings; capable of storing 36 programs.
6. Compatible with various rotor heads; transparent glass window for easy observation.
7. Magnetic drive: maintenance-free, non-contact drive, fully sealed.
8. Safety in use: inductive electric self-suction door lock ensures the centrifugal concentrator can only start when the door cover is fully closed and locked.
9. Can be used in conjunction with freeze-drying systems.

Accessories For Purchase

imagesnameog_modelcold trap solventcold trap temp.description
imagesnameog_modelcold trap solventcold trap temp.descriptionog_priceprice Laboratory High Speed Centrifuge Room

01/ Used with the IC Series Cold Trap
01/ Used with the IC Series Cold Trap Laboratory High Speed Centrifuge Room Temperature~+100°C ±1°C

02/ Used with the Intact Freeze Dryer as a Cold Trap
02/ Used with the Intact Freeze Dryer as a Cold Trap Cold trap IC-5002 2L -50°C The evaporation rate is influenced not only
Cold trap
IC-5002
2L
-50°C
The evaporation rate is influenced not only by the energy input but also by the pumping speed of the vacuum pump. The main
factor affecting the efficiency of the vacuum pump is the large evaporative surface area of the sample, rather than the sample quantity or volume. To reduce evaporation time, we
recommend using a cold trap in conjunction with centrifugal concentration. This not only helps in condensing water vapor but also increases the vapor density of organic solvents, making it easier for condensation to occur.

imagesnamerotor typerotor volume
Rotor
Angle Rotor
42x1.5/2ml
Laboratory High Speed Centrifuge Room Temperature~+100°C ±1°C
Rotor
Angle Rotor
108x1.5/2ml
Rotor
Angle Rotor
48x5ml
Rotor
Angle Rotor
30x10ml
Laboratory High Speed Centrifuge Room Temperature~+100°C ±1°C
Rotor
Angle Rotor
24x15ml
Laboratory High Speed Centrifuge Room Temperature~+100°C ±1°C
Rotor
Angle Rotor
8x50ml
Laboratory High Speed Centrifuge Room Temperature~+100°C ±1°C
Rotor
Angle Rotor
6x100ml
Laboratory High Speed Centrifuge Room Temperature~+100°C ±1°C
Rotor
Angle Rotor
16*20ml Sample vial
Laboratory High Speed Centrifuge Room Temperature~+100°C ±1°C
Rotor
Angle Rotor
16*5ml+8*4ml+8*3ml
Laboratory High Speed Centrifuge Room Temperature~+100°C ±1°C
Rotor
Microplate Rotor
2x96 well

imagesnamedescription
Laboratory High Speed Centrifuge Room Temperature~+100°C ±1°C
Vacuum Pump
Oil pump (standard configuration)
Laboratory High Speed Centrifuge Room Temperature~+100°C ±1°C
Vacuum Pump
Chemical corrosion-resistant
diaphragm pump (optional)
Laboratory High Speed Centrifuge Room Temperature~+100°C ±1°C
Vacuum Pump
Chemical corrosion-resistant
hybrid pump (optional)