Inductively Coupled Plasma Emission Spectrometer BICP-703

Inductively Coupled Plasma Emission Spectrometer BICP-703

  • Sea, Air, Door to Door Shipping
  • 1 Year Warranty
  • US & European Standards
Inductively coupled plasma atomic emission spectroscopy (ICP-AES) is very sensitive technique in emission spectroscopy that measures the mass percentage of the metals in the metal/polymer nanocomposites by exciting its metal atoms/ions by using a plasma and analyzing the emission wavelength of the electromagnetic radiation.
  • Full spectrum direct reading. Precision constant temperature,35 ± 0.1 °C,Distributed nitrogen purging, normal purging 1.8 L/min, fast purging 3.8 L/min.
Instant Quote
Specification Features Applications
RFPower technical parameter: 
      Circuit type:solid-state RF power supply, with function of automatch
      Frequency:27.12 MHz ± 0.05%
      Frequency Stability< 0.1 %
      Power Output:800 W - 1500 W
      Power Output Stability:< 0.3 %
      Escaped RF radiation:30 cm away from the instrument, electric field: E < 2V/m
Sampling System Technical Parameter: 
      Output working coil inner diameter:25 mm
      Torque tube:Three concentric, external diameter 20 mm
      Coaxial nebulizer:Outer diameter 6 mm
      Double barrel atomizing chamber:Outer diameter 34 mm
Gas Flow Controls: 
      Plasma Argon Flowmeter:(100-1000) L/h (1.6-16 L/min)
      Auxiliary Argon Flowmeter:(100-100) L/h (0.16-1.66 L/min)
      Carrier Argon Flowmeter:(100-100) L/h (0.16-1.66 L/min)
      Pressure Maintaining Valve:0 - 0.4 MPa
      Cooling Water:Temperature: 20-25 °C, Rate of Flow >5 L/min, Hydraulic Pressure >0.1 Mpa
Technical index of spectrometer: 
      Grating:Middle step grating,52.67 Ip/mm,64 sparkle angle
      Wavelength range:160-1000 nm
      Numerical aperture:F < 8, ultra-high luminous flux to ensure the detection limit and sensitivity of the instrument
      Resolution:< 0.0065 nm @ 200 nm
      Astigmatism:Equivalent background concentration of 10000 ppm Ca solution at As 189.042 nm <2 ppm
      Light chamber:Precision constant temperature,35 ± 0.1 °C,Distributed nitrogen purging, normal purging 1.8 L/min, fast purging 3.8 L/min
Testing device technical specifications: 
      Detector:CID
      Target Size:27.6 mm x 27.6 mm, 1024 x 1024 addressing detection units
      Reading mode:Non-destructive read (NDRO), full reading (FF) and arbitrary read integral (RAI)
  • Full spectrum direct reading. Precision constant temperature,35 ± 0.1 °C,Distributed nitrogen purging, normal purging 1.8 L/min, fast purging 3.8 L/min.
Environmental, Metallurgical, Geological, Petrochemical, Pharmaceutical, Food safety