Thermal Cycler BFJ1R2
Thermal Cycler- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards

Specifications
Model | BFJ1R2 |
Capacity | 96x0.2ml + 77x0.5ml |
Formats | 0.1/0.2/0.5ml, 8 strips, 12 strips, Half skirt 96 wells plate, No skirt 96 wells plate |
Reaction Volume | 5-80μl, 5-120μl |
Temperature Range | 0-105°C |
MAX. Ramp Rate | 4.5°C/s |
Uniformity | ≤±0.2°C |
Accuracy | ≤±0.1°C |
Display Resolution | 0.1°C |
Temperature Control | Block/Tube |
Ramping Rate Adjustable | 0.01-4.5°C/s |
Hold at 4°C | Forever |
Gradient Uniformity | ≤±0.2°C |
Gradient Accuracy | ≤±0.2°C |
Gradient Temp. Range | 30-105°C |
Gradient Spread | 0.1-30°C |
Hot Lid Temperature | 30-115°C |
Hot Lid Height Adjustable | Stepless Adjustable |
Number of Programs | 200,000+ (USB FLASH) |
Max. No. of Step | 30 (Multiple nested PCR experiments) |
Max. No. of Cycle | 200 (Up to 100,000 in nested cycles) |
Time Increment/Decrement | 1s-600s, Long PCR is available |
Temp. Increment/Decrement | 0.1-10.0°C, Touchdown PCR is available |
Pause Function | Yes |
Auto Data Protection | Yes |
GLP Report | Record the running information of each step of the program to provide accurate data support for the analysis of experimental results |
File Encryption Function | Individual program files can be encrypted |
User Management Privilege | Three levels of access (administrator, user, guest) |
Email Notification | Email notification after experiment is over |
Lock Screen Function | Prevents accidental termination of the program being experimented on |
PC-LINK Function | Simultaneous on-line monitoring of more than 250 instruments |
Mobile Phone APP | Simultaneous on-line monitoring of more than 250 instruments |
Communication | USB 2.0,LAN,WIFI |
Dimensions | 390mmx270mmx255mm(LxWxH) |
Weight | 9kg |
Features
1. Six pieces of long service life Peltier heating units and form 3 circuits to control 3 temperature zones.2. Android operating system, capacitive touch screen, high-definition TFT display (8", 800x600 pixels, 16 colors) with graphical interface provides easy use for setting up and monitoring.
3. The running program and left time can be displayed in real time, allow to edit file when program is running.
4. Hot lid temperature and hot lid work mode can be set to meet different experiments need.
5. Built-in WIFI module, one machine can control multiple PCR machines at the same time through mobile APP or PC software.
6. Email notification after experiment is over.
7. Intelligent Economic
8. Convenient
Features

Stepless adjustable hot lid, fit tubes of different heights to avoid tube melt and evaporation.

Block