Get Quote ▼

Thermal Cycler BFA-1201

Gene Amplification Instrument, Gene Cycler
The PCR instruments adopts Linux operating system, matched with 10.1-inch capacitive touch screen, with simple and smooth operation, accurate and fast data display; Front and rear air ducts allow instruments to be placed side by side, saving space; Zero evaporation technology, sealing 96 holes separately; Pressure rod type hot cover, close and tighten the...
  • Gene amplification instrument
  • Adopting high-efficiency and long-life Peltier refrigeration chips, with a maximum heating rate of 7.0 °C/s and a maximum cooling rate of 6.0 °C/s, saving valuable experimental time.
  • The company's unique innovative pressure rod type hot cover component patented technology, elastic downward pressure locking linkage mechanism, and hot cover thermal conductivity design ensure that the reagents in each hole evaporate "zero" during the experiment.
  • Automatic power-off protection, automatically running unfinished programs after power restoration
Old SKU: BFA1M1
Specifications Features Applications Get Quote

Specifications

ModelBFA-1201
U Disk functionUnlimited downloads on USB flash drive, instrument supports import and export
Types of consumables0.2ml single tube, 8-Tube Strips
Communication Interface1*LAN 1*RS232 2*USB
96 well plate96 well plate (excluding Full skirt)
Wireless functionSupports WIFI connection
Refrigeration chipImported refrigeration chips
Air duct designFront in bottom out air duct design to protect operators from burns
LCD10.1-inch high-definition full-color touch LCD screen
SystemLinux
LanguageBilingual in Chinese and English
Temperature function
Block temp. control range0~105°C
Temperature accuracy≤±0.1°C
Maximum heating rate7.0°C/s
Temp. Display Resolution0.1°C
Maximum cooling rate6.0°C/s
Temperature ControlBlock/Sample temperature control
Temperature Uniformity≤±0.2°C
Variable Temp. Rate0.1~6.0°C/s
Hot Lid Function
Hot Lid Temp. Range30~110°C adjustable
Automatic lid closing functionAutomatically close the hot cover when the block temperature drops below 20
Gradient function
Gradient temp. repeatability≤±0.1°C
Gradient temp. uniformity≤±0.25°C
Gradient Temp. Accuracy≤±0.5°C
Gradient Range30°C~105°C
Temp. difference range1°C~30°C
Gradient temp. point distribution12 columns
Programming function
Max. stepUp to 10 stages, max. 100 steps
Program Skip FeatureYes
Max. number of cyclesSingle cycle max. of 100, secondary nesting up to a max. of 10000, can do nested PCR experiment
Multi-user functionRealize multi person use without interfering with each other
Audit trailYes
Tm calculatorYes, users only need to input the base sequence to calculate the melting temperature and annealing temperature, which improves work efficiency
Single step time range1''~99'59'' or set infinite time
Time increasing/decreasing1~1200s, can do Long PCR experiments
Temp. increase/decrease0.1~20°C, can do Touchdown PCR
Low temperature insulationCan be set for unlimited low-temperature insulation time
Power-off protectionYes
Program pause functionYes
Program GuideUsers only need to modify a few parameters to quickly experiment
Program import and export functionFiles can be exchanged between instruments of the same type through USB drives
Other Parameters
Wide voltage rangeGlobal universal power supply 100~240V, 50/60Hz
Fuse220V~6A or 110V~12A
Max. power800W
Size (W x D x H)273mm x 373mm x 264mm
Net weight10kg

Features

Gene amplification instrument
Adopting high-efficiency and long-life Peltier refrigeration chips, with a maximum heating rate of 7.0 °C/s and a maximum cooling rate of 6.0 °C/s, saving valuable experimental time.
The company's unique innovative pressure rod type hot cover component patented technology, elastic downward pressure locking linkage mechanism, and hot cover thermal conductivity design ensure that the reagents in each hole evaporate "zero" during the experiment.
Automatic power-off protection, automatically running unfinished programs after power restoration
The hot cover is made of silicone material with excellent sealing properties, and the hot cover is vertically pressed down to ensure that the reagents in each hole evaporate "zero" during the experiment.
Equipped with memory function, one click quick running of the previous program, convenient and efficient.
Has incubation function and the incubation temperature range is 0~105 °C
Ultra large storage capacity, capable of storing up to 100000 programs inside the machine
Hot cover temperature and working mode can be set to meet different experimental needs
User login management, user password protection, ensuring data security
Built in WIFI module, capable of monitoring instrument operation status on mobile phones
USB interface, supports importing and exporting data, supports mouse control of instruments
Featuring a 12 column gradient function, it facilitates users to quickly optimize reaction conditions
Equipped with a 10.1-inch display screen, it can run and view real-time operating status without connecting to a computer
Multi user functionality enables multiple users to use without interfering with each other, and can also manage users to ensure the security of experimental data
Supports saving program files in folders, making it convenient for users to manage program files.

1. Zero "evaporation patent technology
The hot cover is made of soft silicone material with excellent sealing properties. With the hot cover vertically pressed down, the 96 holes are sealed one-to-one, ensuring that the reagents in each hole "zero" evaporate during the experiment.
1. Zero "evaporation patent technology The hot cover is made of soft silicone material with excellent sealing properties.

2. Pressure Rod Patent Technology
The patented hot lid technology achieves vertical downward pressure, ensuring "zero" evaporation technology: the innovative hot lid elastic downward pressure locking linkage mechanism and hot lid thermal conductivity design ensure that the reagents in each hole do not evaporate during the experiment. The following is a specific description of this
Technology:
2. Pressure Rod Patent Technology The patented hot lid technology achieves vertical downward pressure, ensuring "zero"

Applications

The application scope of gene amplifiers is very wide, in various fields such as medicine, forensic science, biological research, agriculture and animal husbandry, food safety testing, environmental monitoring, biotechnology, public health, pharmaceutical industry, and gene therapy. As an important experimental equipment, it plays an irreplaceable role in promoting the development and application of life sciences.
The application scope of gene amplifiers is very wide, in various fields such as medicine, forensic science, biological
Forensic medicine

Clinical diagnosis Thermal Cycler Unlimited downloads on USB flash drive, instrument supports import and export 0.2ml single
Clinical diagnosis

Biological research Thermal Cycler Unlimited downloads on USB flash drive, instrument supports import and export 0.2ml
Biological research

Animal husbandry Thermal Cycler Unlimited downloads on USB flash drive, instrument supports import and export 0.2ml single
Animal husbandry

Food safety Thermal Cycler Unlimited downloads on USB flash drive, instrument supports import and export 0.2ml single tube,
Food safety

Environment detection Thermal Cycler Unlimited downloads on USB flash drive, instrument supports import and export 0.2ml
Environment detection

Public health Thermal Cycler Unlimited downloads on USB flash drive, instrument supports import and export 0.2ml single
Public health

Pharmaceutical industry Thermal Cycler Unlimited downloads on USB flash drive, instrument supports import and export 0.2ml
Pharmaceutical industry

Gene therapy Thermal Cycler Unlimited downloads on USB flash drive, instrument supports import and export 0.2ml single tube,
Gene therapy

Agriculture Thermal Cycler Unlimited downloads on USB flash drive, instrument supports import and export 0.2ml single tube,
Agriculture

Get Quote