Get Price

Single Beam UV Visible Spectrophotometer BSSUV-303-PC

Spectrophotometer

Simple-to-use instruments with advanced performance, its stray light is only 0.05%T. The local stand-alone software provides functions of Photometry, Quantitative Test, Kinetics and System Utilities functions.

Key Features
  • Large LCD screen (128*64 Dots).
  • The system can also save the test results, a total of 200 groups of data and 200 standard curves can be saved in the RAM. Convenient for check and reload.
  • Data can be restored after a sudden power cut.
  • Auto setting wavelength.
SKU: BSSUV-303-PC
Old SKU: BHV1C7
Pricing & Resources
  • Up to 3-Year Product Warranty
  • US & EU Compliance Standards
  • Door-to-Door Shipping
Recently Shipped To: ๐Ÿ‡ป๐Ÿ‡ณ Vietnam , ๐Ÿ‡ท๐Ÿ‡ผ Rwanda , ๐Ÿ‡ง๐Ÿ‡ท Brazil , ๐Ÿ‡ต๐Ÿ‡น Portugal
Get Quote Download Catalog
Specifications Features Accessories For Purchase Get Quote

Technical Specifications

Detailed operating and construction parameters for this model.

ModelBSSUV-303-PC
Wavelength Range190-1100 nm
Spectral Bandwidth4 nm
Optical SystemSingle Beam, Grating 1200 lines/mm
Wavelength Accuracyยฑ0.5 nm
Wavelength Repeatability0.3 nm
Photometric Accuracyยฑ0.5%T or ยฑ0.004A @ 1A
Photometric Range0-200%T,-0.3-3 A, 0-9999 Conc
Stray Light0.05%T @ 220 nm, 360 nm
Stabilityยฑ0.001 A/h @ 500 nm
DisplayGraphic LCD (128*64 dots)
Keyboard22 Membrane keypad
Standard Cell HolderStandard 10 mm pathlength cuvette
Sample Compartment4-position 10 mm cell changer
Light SourceTungsten & Deuterium lamp
OutputUSB Port & Parallel Port (Printer)
Power RequirementAC 110/220 V 50/60 Hz
Dimensions (LxWxH)470x373x187 mm
Weight14 kg

Product Features

Key design, performance, usability, and safety advantages.

Large LCD screen (128*64 Dots).

The system can also save the test results, a total of 200 groups of data and 200 standard curves can be saved in the RAM. Convenient for check and reload.

Data can be restored after a sudden power cut.

Auto setting wavelength.

Tungsten lamp & Deuterium lamp can be turned on/off individually to extend lifetime.

The optional application software M. Wave Professional provides complete control of the spectrophotometer from a computer through the built-in USB port. It can expand to the following functions: Quantitative, Kinetics, Wavelength Scan, Multi-wavelength & DNA/Protein Test.

Pre-aligned design makes it convenient to change lamps.

Large sample compartment; it can accommodate 5-100 mm path length cuvettes with optional holders. A variety of optional accessories are available.


Main Menu:

Move the cursor on the function menu you want, then press ENTER key to go into the corresponding interface.

Main Menu: Move the cursor on the function menu you want, then press ENTER key to go into the corresponding interface.


Basic Mode:

Absorbance, Transmittance or Concentration measurements.

It can display and save 200 groups of data, 5 groups per screen.

Basic Mode: Absorbance, Transmittance or Concentration measurements. It can display and save 200 groups of data, 5 groups


Kinetics:

This mode may be used for time course scanning or reaction rate calculations. Abs. VS Time graphs are displayed on the screen in real time. It can record 1000 data.

Kinetics: This mode may be used for time course scanning or reaction rate calculations. Abs. VS Time graphs are displayed on


Quantitative:

Standard Curve

At most, 9 standard samples can be used to establish a standard curve. The curve and its equation will be displayed on the screen simultaneously. You can measure your unknown concentration solutions by the curve. Total 200 curves can be saved in the RAM.

Coefficient Method

If you have known the coefficient K*a + b is known, you can input them directly by the button, and then test your unknown solutions.

Quantitative: Standard Curve At most, 9 standard samples can be used to establish a standard curve. The curve and its


System Utilities:

Lamp management, time & date set, obtain dark current, calibrate wavelength, default system, and some other system functions.

System Utilities: Lamp management, time & date set, obtain dark current, calibrate wavelength, default system, and some


M. Wave Professional PC-Control Software:


Brief Introduction:

M. Wave Professional application software is based Microsoft Windows, the instrument can be controlled by PC software through the built-in USB communication port, which makes the UV/Vis Series with more functions and easy to control.


Quantitative:

Use up to 20 standards to establish a standard curve. Three methods for fitting a curve:

Linear fit.

Linear through zero.

Square fit.

Quantitative: Use up to 20 standards to establish a standard curve. Three methods for fitting a curve: Linear fit. Linear


Multi-wavelength Test:

You can set up to 20 wavelengths to measure a sample.

Multi-wavelength Test: You can set up to 20 wavelengths to measure a sample. Single Beam UV Visible Spectrophotometer


Wavelength Scan:

Automatically records peaks and valleys.

The quantity of the curves stored is unlimited.

Post-run manipulation and processing includes:

Re-scaling axes, curve.

Smoothing, combination, zooming, overlap.1 to 4 derivatives.

Wavelength Scan: Automatically records peaks and valleys. The quantity of the curves stored is unlimited. Post-run


Kinetics:

The Kinetics mode may be used for scanning time courses or reacting rate calculations. Abs. Vs. Time graphs are displayed.

Kinetics: The Kinetics mode may be used for scanning time courses or reacting rate calculations. Abs. Vs. Time graphs are


DNA/Protein Test:

Optional two formulas:

DNA Concentration = 62.9A260 - 36.0A280 or 49.1A260 - 75.8A230

You can also enter other wavelengths and factors to calculate.

DNA/Protein Test: Optional two formulas: DNA Concentration = 62.9A260 - 36.0A280 or 49.1A260 - 75.8A230 You can also enter

Functions:

Photometry

Absorbance, Transmittance or Energy measurements. It can display and save 200 groups of data, 5 groups per screen.

Quantitative

Standard Curve

At most, 9 standard samples can be used to establish a standard curve. The curve and its equation will be displayed on the screen simultaneously. You can measure your unknown concentration solutions by the curve.

A total of 200 curves can be saved in the Memory.

Coefficient Method

If the coefficient k & b in the formula C = k*a + b is known, you can input them directly by the button, and then test your unknown solutions.

Kinetics

This mode may be used for time course scanning or reaction rate calculations. Abs. VS Time graphs are displayed on the screen in real time. It can record 1000 data.

System Utilities

Lamp management, time & date set, obtain dark current, calibrate wavelength, default system, and some other system functions.

Accessories For Purchase View compatible optional accessories and additional items available separately.
Images
Name
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Micro Cell Holder
(Beam height: 15mm)
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
8-Position Auto Cell Changer
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
4-Cell Holder for 10mm SQU.cuvette
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
4-Cell Holder for 50mm SQU.cuvette
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
4-Cell Holder for 100mm SQU.cuvette
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Square Cuvettes
Glass :10 mm
20 mm
30 mm
50 mm
100 mm
Square cuvettes Quartz:10 mm
20 mm
30 mm
50 mm
100 mm
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Micro cell, Quartz
(Beam height: 15mm)
100UL
200UL
500UL
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Sipper System
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Constant-Temperature System
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Constant-Temperature Sipper System
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Test Tube Holder
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Cylindrical Cell Holder
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Solid Sample Holder (Single Cell)
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Water-Jacketed Cell Holder
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
10mm Water-Jacketed
4-Cell Holder
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Milas Deuterium
Lamp
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Halogen Lamp(Philips)
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Halogen Lamp(Philips)
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Halogen Lamp(Osram)
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Self Masking Cont. Flowthrough G.Cell
(Beam height: 15mm)
5mm
10mm
20mm
30mm
Self Masking Cont. Flowthrough Q. Cell
(Beam height: 15mm)
5mm
10mm
20mm
30mm
Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm
Thermal Printer

Get Quote