Nano Spectrophotometer BSNA-201
Micro-spectrophotometer
Biolab Nano spectrophotometer is a compact, micro volume UV Visible Spectrophotometer with enhanced sensitivity that can detect samples at 3ng/μl. It gives you fast measurement typically less than 5sec\sample and provides rapid and reproducible results without prior dilution. With robust instrumentation and ease of use, our product is most preferred for...
- Wavelength range: 200nm-800nm
- Wavelength accuracy: ±1.0nm
- Easy user interface
- Reduce sample loss and eliminate the need for dilution by using low volumes of samples in 0.5μl to 2.0μl for sample measurement. The appropriate path length can be selected automatically or by manual selection.
Old SKU: BEQ1E1
Specifications
| Model | BSNA-201 |
| Minimum Sample Size | 0.3-2.0 μl |
| Wavelength Range | 260 nm, 230 nm and 280 nm |
| Wavelength Accuracy | Fixed wavelength point |
| Wavelength Reproducibility | <±0.2 nm |
| Spectral Bandwidth | ≤5 nm |
| Spectral Resolution | 5 nm |
| Absorbance Range | 0.2-75 (10mm equivalent absorbance) |
| Absorbance Accuracy | 0.01 |
| Absorbance Precision | 0.002 Abs |
| Path Length | 1 mm, 0.2 mm |
| Light Source | Xenon flash lamp |
| Life Time of Lamp | 10^9 flashes upto 10 years |
| Detector | UV Detector |
| Detection Range | Nucleic acid up to 10-3750 ng/μl (dsDNA); Protein up to 0.5 mg/ml-110 mg/ml (BSA) |
| Start-up Time | < 5s |
| Measurement Time | < 5s |
| Dimension (W/D/H) | 240x220x140 mm |
| Weight (Net/Gross) | 2.35 kg |
| Power | 12V 4A |
| Power Supply | 90-250V 50/60Hz |
Features
Wavelength range: 200nm-800nm
Wavelength accuracy: ±1.0nm
Easy user interface
Reduce sample loss and eliminate the need for dilution by using low volumes of samples in 0.5μl to 2.0μl for sample measurement. The appropriate path length can be selected automatically or by manual selection.
Rapid measurements. Read-time is typically takes less than 5sec per sample without washing cuvettes or dilutes the samples
Reliability and robust instrumentation. Easy to use interface
Press-to-read feature reduces the amount of time .Optics with no moving parts minimizes the incidence of optical misalignment
Calibration curves, kinetics or ratio measurements are displayed at the touch of a button at a connected computer.
Equipped with a built in printer
Wavelength accuracy: ±1.0nm
Easy user interface
Reduce sample loss and eliminate the need for dilution by using low volumes of samples in 0.5μl to 2.0μl for sample measurement. The appropriate path length can be selected automatically or by manual selection.
Rapid measurements. Read-time is typically takes less than 5sec per sample without washing cuvettes or dilutes the samples
Reliability and robust instrumentation. Easy to use interface
Press-to-read feature reduces the amount of time .Optics with no moving parts minimizes the incidence of optical misalignment
Calibration curves, kinetics or ratio measurements are displayed at the touch of a button at a connected computer.
Equipped with a built in printer
Applications
Ideal choice for quantitation of protein, DNA, RNA and photometric measurements in analytical labs and research areas.