Nano Spectrophotometer BJN-4501
Micro-volume Spectrophotometer
Key Features
- Microscale sample testing; only 0.5-2 μL is required to complete the test, with a minimum sample volume of 0.5 μL. Supports both ultramicro and cuvette measurement.
- Wide detection range, up to 500 times that of a traditional spectrophotometer.
- Most samples can be tested directly without dilution.
- Direct testing with no warm-up required; suitable for container testing and routine testing.
- Full wavelength coverage of 190-1100 nm with 1 nm accuracy; automatic wavelength scanning from 190-900 nm.
- Compact and portable design, suitable for on-site testing.
- 2-in-1 functionality with support for OD600 detection, suitable for measuring the growth density of cells, bacterial cultures, yeast, and other samples.
- Built-in thermal printer with printing capability; can store approximately 100,000 sets of detection data and supports data export through a USB interface.
SKU: BJN-4501
Pricing & Resources
- Up to 3-Year Product Warranty
- US & EU Compliance Standards
- Door-to-Door Shipping
Technical Specifications
Detailed operating and construction parameters for this model.
| Model | BJN-4501 |
| Wavelength Range | 190-900nm |
| Spectral Bandwidth | |
| Wavelength Accuracy | 1nm |
| Minimum Sample Size | 0.5 μL |
| Optical Distance | 0.02 / 0.05 / 0.1 / 0.5 / 1 mm (five detection light paths, automatic switching) |
| Wavelength Resolution | 1 nm |
| Absorbance Accuracy | ±1% (0.76 at 260 nm) |
| Absorbance Resolution | 0.002 Abs (at 1 mm optical distance) |
| Absorbance Range | 0-750 A (10 mm equivalent) |
| OD600 Absorbance Range | 0-4.000 Abs |
| OD600 Absorbance Stability | [0, 3) ≤0.5%; [3, 4) ≤2% |
| OD600 Absorbance Repeatability | [0, 3) ≤0.5%; [3, 4) ≤2% |
| Nucleic Acid Detection Range | 1.5-37,500 ng/μL (dsDNA); lower limit 1.5 ng/μL |
| Protein Detection Range | 0.05-1110 mg/mL (BSA); 0.03-540 mg/mL (IgG) |
| Sample Pedestal Material | 304 Stainless Steel and Quartz |
| Measurement Time | <5 s |
| Detector | 2048-unit CMOS linear array sensor |
| Light Source | Xenon Flash Lamp |
| Dimensions (W x D x H) | 310 x 221 x 176 mm |
Product Features
Key design, performance, usability, and safety advantages.
Microscale sample testing; only 0.5-2 μL is required to complete the test, with a minimum sample volume of 0.5 μL. Supports both ultramicro and cuvette measurement.
Wide detection range, up to 500 times that of a traditional spectrophotometer.
Most samples can be tested directly without dilution.
Direct testing with no warm-up required; suitable for container testing and routine testing.
Full wavelength coverage of 190-1100 nm with 1 nm accuracy; automatic wavelength scanning from 190-900 nm.
Compact and portable design, suitable for on-site testing.
2-in-1 functionality with support for OD600 detection, suitable for measuring the growth density of cells, bacterial cultures, yeast, and other samples.
Built-in thermal printer with printing capability; can store approximately 100,000 sets of detection data and supports data export through a USB interface.
Supports intelligent automatic measurement without the need to press a key, simplifying the detection process.