Get Quote ▼

Microplate Reader BFA-8601

Full Wavelength Microplate Reader
Full Wavelength Microplate Reader is a high-quality reader based on a grating monochromator with a wavelength range of 200~1100nm. It is designed for medical, biological laboratories, and drug development institutions, and can be used for spectral scanning, endpoint method, and kinetic detection. Compared with similar products on the market, it has the...
  • Diverse types of carriers:
  • Suitable for 96 well plates, 384 well plates, ultramicro plates, and cuvette, with a variety of choices to meet your experimental needs. The cuvette mode has independent cuvette software, which can be directly used for photometric detection, kinetic or spectral scanning, and standard curve establishment. The ultra trace detection plate is designed for rapid detection of small volume samples. Supports simultaneous analysis of up to 16 samples. Users can quickly and conveniently clear the tested samples for continuous measurement.
  • Wide and accurate lighting system:
  • Using a flickering xenon lamp as the light source, wavelength selection is carried out through an advanced grating monochromator system. The wavelength detection range is 200~1100 nm, and full spectrum scanning can be performed in 1 nm steps. The self check function of the instrument during startup checks key components such as the light source, detector, and carrier position to ensure stable and reliable operation of the instrument.
Specifications Features Get Quote

Specifications

ModelBFA-8601
Display10 inch high-resolution capacitive touch screen
Light sourceXenon flash lamp / Number of flashes > 10^9
Wavelength range200-1100 nm
Wavelength accuracy2 nm
Wavelength repeatability0.2 nm
Optical systemGrating monochromator, 1 nm stepper
Reading range0 - 4.0 OD
Bandwidth< 2.5 nm
Carrier type96 well plate, 384 well plate, microplate, cuvette
Cuvette size (WxDxH)12.5 mm x 12.5 mm x 40-45 mm
Detection system2 silicon photoelectric detection tubes, 1 measurement, 1 reference
Linear @450nmR² ≥ 0.999, [0.0 - 3.0 Abs]
Absorbance Accuracy @450nm±(1.0% + 0.003 Abs), (0-2.0 Abs); ±2.0%, (2.0-2.5 Abs)
Repeatability of absorbance @450nmPrecision mode: CV < 0.5% or SD < 0.003; Quick mode: CV < 1.0% or SD < 0.003
Measure speed96 well plate for 8 seconds; 384 well plate for 15 seconds
OscillationLinear, with 3 adjustable speeds
Temperature rangeRoom temperature +4°C to 65°C
Temperature accuracy±0.5°C @ 37°C
Temperature uniformity±0.5°C @ 37°C
Input powerAC 100-240V, 3A, 50/60Hz
Power300 W
Fuse250V, 3A Φ5x20
Dimensions (WxDxH)300 mm x 430 mm x 242 mm
Net weight15 kg

Features

Diverse types of carriers:
Suitable for 96 well plates, 384 well plates, ultramicro plates, and cuvette, with a variety of choices to meet your experimental needs. The cuvette mode has independent cuvette software, which can be directly used for photometric detection, kinetic or spectral scanning, and standard curve establishment. The ultra trace detection plate is designed for rapid detection of small volume samples. Supports simultaneous analysis of up to 16 samples. Users can quickly and conveniently clear the tested samples for continuous measurement.
Diverse types of carriers: Suitable for 96 well plates, 384 well plates, ultramicro plates, and cuvette, with a variety of
Diverse types of carriers: Suitable for 96 well plates, 384 well plates, ultramicro plates, and cuvette, with a variety of
Diverse types of carriers: Suitable for 96 well plates, 384 well plates, ultramicro plates, and cuvette, with a variety of
Diverse types of carriers: Suitable for 96 well plates, 384 well plates, ultramicro plates, and cuvette, with a variety of

Wide and accurate lighting system:
Using a flickering xenon lamp as the light source, wavelength selection is carried out through an advanced grating monochromator system. The wavelength detection range is 200~1100 nm, and full spectrum scanning can be performed in 1 nm steps. The self check function of the instrument during startup checks key components such as the light source, detector, and carrier position to ensure stable and reliable operation of the instrument.
Wide and accurate lighting system: Using a flickering xenon lamp as the light source, wavelength selection is carried out

Equipped with incubation and oscillation functions:
Equipped with incubation function, the average temperature difference between wells is ±0.5°C at room temperature +4°C~65°C and 37°C. The oscillation frequency of linear oscillation mode is divided into low, medium, and high gears for users to choose from.
Equipped with incubation and oscillation functions: Equipped with incubation function, the average temperature difference

Powerful and rich software programs:
A fully functional data analysis software that can meet the vast majority of data processing needs. Built in multiple data processing methods, including quantitative curve fitting, qualitative analysis, dynamic calculation, custom equations, and four parameter fitting, and supports customized services for customers. Calculation methods can be added according to customer needs. Data can be exported to Excel with just one click, and detailed result reports can also be generated through built-in tools.
Powerful and rich software programs: A fully functional data analysis software that can meet the vast majority of data

Simple and convenient operation mode:
10.1-inch touchscreen display, capable of completing the entire testing process on a single machine, easy to operate, simple and user-friendly, with a graphical interface design and simple program editing. Various testing programs can be preset. 2 USB ports and 1 Ethernet port, supporting USB data export or connection to a computer.
Simple and convenient operation mode: 10.1-inch touchscreen display, capable of completing the entire testing process on a

User Interface:
User Interface: Main Interface Microplate Reader 10 inch high-resolution capacitive touch screen Xenon flash lamp / Number
Main Interface

Parameter settings Microplate Reader 10 inch high-resolution capacitive touch screen Xenon flash lamp / Number of flashes >
Parameter settings

Board layout interface Microplate Reader 10 inch high-resolution capacitive touch screen Xenon flash lamp / Number of
Board layout interface

Settings interface Microplate Reader 10 inch high-resolution capacitive touch screen Xenon flash lamp / Number of flashes >
Settings interface

Get Quote