Get Price

Laboratory Vertical Autoclave BDN-101

Vertical Autoclave, Standard

We have always prioritized safety since its establishment, adhering to the highest industry standards and providing multiple safety guarantees from design, manufacturing,use,application to service.

Key Features
  • Safety:
  • 1. Triple protection for lack of water
  • The bottom of the sterilization chamber is equipped with three different dry burning protection devices:liquid expansion type, copper temperature sensing type, and electric ion type (water level sensor), to avoid misjudgment caused by a single method.
  • 2. Saturated steam monitoring
SKU: BDN-101
Old SKU: BEO1B1
Pricing & Resources
  • Up to 3-Year Product Warranty
  • US & EU Compliance Standards
  • Door-to-Door Shipping
Recently Shipped To: 🇵🇦 Panama , 🇹🇳 Tunisia , 🇵🇷 Puerto Rico , 🇮🇪 Ireland
Get Quote Download Catalog
Specifications Features Accessories For Purchase Get Quote

Technical Specifications

Detailed operating and construction parameters for this model.

ModelBDN-101
Capacity (L)29
Chamber dimension (Dia*H)(mm)460x570x925
Chamber dimension (Dia*H)(mm) ΦΦ320x394
Rated power (W)2300
SUS304 Basket Size (pcs)(Φ300x265)x1
Working Environment1P 220V±10% 14A 50Hz/60Hz
Temperature display accuracy0.1°C
Working Environment5°C~40°C, RH < 85%
Chamber materialSUS304 (opt. SUS316L)
Sterilization temp. range105°C~138°C
Lid open wayOne button open / Interlock sensor
Sterilization time1-6000 min
Melting temp.60°C-115°C
Melting time1-6000 min
Warming temp.45°C-79°C
Warming time1-9999 min
Exhaust speed controlAutomatic 6-level discharge
Memory function60 programs, 999 cycles by USB
Appointment timer range0-15 days
Pressure gauge-0.1-0.5 MPa
Pressure valve set pressure0.29 MPa
Cooling lock OPEN temp. range40°C-99°C (solid) / 40°C-80°C (liquid)
Sterilization modeLiquid, solid, wrapped instrument, fabric, waste, agar, self-defined
ControllerInspiration II Smart Controller
Cooling wayFast cooling fan
Safety deviceInterlock, double interlock, lid check, dry scorch protection, safety valve, water sensor, over-temp/pressure protection, electrical safety, cooling lock, anti-scald, auto troubleshooting
Biosafety functionOptional 0.2 μm biosafety filter (S models)
6 level exhaust speed controlStandard
Auto water fill-
Drying-
Deodorization-
Access permission5 level
Fast cooling fanStandard
Sterilization recordStandard
USB portStandard
Micro-printerOption
CondenserOption
SUS316L steelOption
Pharma package testing programOption
Air inlet filter-
Display systemLCD
Load thermometer(Floating PT100 sensor)Option
Printing set(printer+digital pressure sensor)Option
Auto drainageOption
APP control/Remote controlOption
Steam collecting wayInternal
Auto cleaningOption
Packing Dimension69*61*125
CBM0.53
Net Weight114
Gross weight135

Product Features

Key design, performance, usability, and safety advantages.

Safety:

1. Triple protection for lack of water

The bottom of the sterilization chamber is equipped with three different dry burning protection devices:liquid expansion type, copper temperature sensing type, and electric ion type (water level sensor), to avoid misjudgment caused by a single method.

2. Saturated steam monitoring

The system automatically monitors the purge out of cold air to ensure the pure steam environment

3. Humanized design

The lid and bench corners are covered with insulation to avoid getting scald

4. Auto troubleshooting

System will monitor the working status, and will cut the power, send out alarm, and report the error information once any abnormal situation detected

5.Electrical protection

Prevention for overcurrent,short circuit and electricity leakage

6.Cooling LOCK open temperature

Each program can set different lid OPEN temperatures,especially for liquid programs ,so as to prevent users from opening the lid and causing burns when the articles are still in a high temperature state.

7.Evenly distributed interlock

Evenly distributed interlock device is safer and more reliable than ordinary interlocking devices

8.Real time monitor

System will monitor the lid locking, pressure and temperature status on a real time basis to guarantee the safe and successful work of the autoclave

9.Double protection for over pressure

Mechanical pressure gauge and electric sensing system, once pressure is abnormal, system will cut power, release the pressure and send out an alarm

10.Safety test function

Regular testing of system security and safety protection measures is possible

11.Temperature monitor

Power cut and alarming sent, if there is temperature is too high or temperature rising is abnormal

12. One button to open

Press slightly to close, one button to open ( if not safe inside, can not open)


Note: Requirements for sterilization water: distilled water (conductivity not less than 3 p S/em)

When configured as an S biosafety type, a condenser is standard Spare parts


Note :Baskets can also be customized, as well as melting and warming temperature range


Intelligent:

1.App control (Option)

Download the APP software on your mobile phone, which can monitor the sterilization process in real-time,Query historical data, alarm information, etc.

2.Program memory storage system

Users can set their own program, and save it in the system.

3.Saturated steam monitoring

The system automatically monitors the purge out of cold air to ensure the pure steam environment

4.Calibration port

Offer temperature and pressure interface, together with the 3Q adapter joints, can insert max 15 sensors one time to do the calibration work.

5.Special software for drug packaging materials (option)

The product meets the 2020 Chinese Pharmacopoeia or EP10.2 standards.


Humanization:

1.Just right depth

Conforming to ergonomics, the chamber depths of 29/54/88/120/150L Chamber are 394/726/733/658/819(mm) making it easy to take and place samples and maintain the instrument

2.Front water tank

Front water tank, easy to plug in and out


Advanced:


Colorful LCD screen LCD screen with English and Chinese choice,using text, data, and graphical methods to dynamically

Colorful LCD screen

LCD screen with English and Chinese choice,using text, data, and graphical methods to dynamically display various statuses, the sterilization process is clear at a glance.


Data reading and curve conversion Provide USB interface for easy reading or storage of sterilization data. The sterilization

Data reading and curve conversion

Provide USB interface for easy reading or storage of sterilization data. The sterilization data is converted into curves for case data analysis.


6 level of exhaust speed control After sterilization,you can choose different exhaust speed, and you can adjust it freely at

6 level of exhaust speed control

After sterilization,you can choose different exhaust speed, and you can adjust it freely at any time of exhausting


Auto drainage/Auto cleaning (option) Added with a water pump, press the drainage button to start drainage, or set it to

Auto drainage/Auto cleaning (option)

Added with a water pump, press the drainage button

to start drainage, or set it to timed automatic drainage.Automatic cleaning can be set to regular cleaning or cleaning after each sterilization cycle.


5 level access permission The operation permissions for instruments are divided into five levels, with each level of user

5 level access permission

The operation permissions for instruments are divided into five levels, with each level of user

having an independent password and multiple IDs that can be assigned. Each level of user has

limited access to certain usage permissions


Sterilization record storage Built in large capacity memory, can store 999 sterilization cycles and can be queried, printed

Sterilization record storage

Built in large capacity memory, can store 999 sterilization cycles and can be queried, printed

or exported for easy traceability management


FO value calculation FO value is automatic calculated, can print out by micro-printer Condenser(Option) Equipped with a

FO value calculation

FO value is automatic calculated, can print out by micro-printer

FO value calculation FO value is automatic calculated, can print out by micro-printer Condenser(Option) Equipped with a

Condenser(Option)

Equipped with a professional condenser, the steam generated during the sterilization process is converted into water through the condenser, achieving zero discharge of water vapor/mist.


Slightly press the lid Laboratory Vertical Autoclave 29 460x570x925

Slightly press the lid


Interlock sensor Laboratory Vertical Autoclave 29 460x570x925

Interlock sensor


One button to open Laboratory Vertical Autoclave 29 460x570x925

One button to open


Slightly lift up Laboratory Vertical Autoclave 29 460x570x925

Slightly lift up

Accessories For Purchase View compatible optional accessories and additional items available separately.
Images
Name
Description
Laboratory Vertical Autoclave 29 460x570x925
Micro printer
To print temp. time
and FO value

Printing set:printer+digital
pressure sensor:can print temp.and pressure in data and flowchart way
Laboratory Vertical Autoclave 29 460x570x925
Digital pressure sensor
Printing set:printer+digital
pressure sensor:can print temp.and pressure in data and flowchart way
Laboratory Vertical Autoclave 29 460x570x925
Load thermometer
Floating PT100 sensor
Laboratory Vertical Autoclave 29 460x570x925
Tray
Laboratory Vertical Autoclave 29 460x570x925
Stainless steel bucket
Laboratory Vertical Autoclave 29 460x570x925
IQ/OQ/PQ
(3Q)adapter joint
Laboratory Vertical Autoclave 29 460x570x925
Adjust foot

Get Quote