Get Price
Laboratory Horizontal Autoclave BKK-1402
Horizontal Pressure Steam Sterilizer
Key Features
- Automatically controlled the sterilizing process, easy to operate.
- With drying function, suitable for medical dressing drying.
- With over-temperature, over-pressure auto-protect.
- The door can not be opened until the pressure in the chamber is reduced to 0.027MPa. And the unit can not be started if the door doesn't close well.
- The safety valve will be opened automatically when the inner pressure is over 0.24MPa and the steam would be exhausted in the water tank.
- Automatically cut off the power if the water leak happens, and alarm in the meanwhile.
- The chamber of the sterilizer is made of stainless steel.
SKU: BKK-1402
Pricing & Resources
- Up to 3-Year Product Warranty
- US & EU Compliance Standards
- Door-to-Door Shipping
Technical Specifications
Detailed operating and construction parameters for this model.
| Model | BKK-1402 |
| Capacity | 200L |
| Sterilization Temperature | 134°C |
| Working Pressure | 0.22 MPa |
| Features | With drying function |
| Sterilizing chamber size | 200L Φ515 x 1000 mm |
| Working temperature | 134°C |
| Temperature adjust range | 40-134°C |
| Time for sterilization | 0-60 min |
| Time for drying | 0-60 min |
| Heat average | ≤±2°C |
| Power | 9 kW / 380 V, 50 Hz |
| Dimension (mm) | 1400 x 670 x 1650 |
| Exterior package dimension (mm) | 1560 x 820 x 1850 |
| G.W / N.W | 350 / 260 kg |
Product Features
Key design, performance, usability, and safety advantages.
Automatically controlled the sterilizing process, easy to operate.
With drying function, suitable for medical dressing drying.
With over-temperature, over-pressure auto-protect.
The door can not be opened until the pressure in the chamber is reduced to 0.027MPa. And the unit can not be started if the door doesn't close well.
The safety valve will be opened automatically when the inner pressure is over 0.24MPa and the steam would be exhausted in the water tank.
Automatically cut off the power if the water leak happens, and alarm in the meanwhile.
The chamber of the sterilizer is made of stainless steel.
Applications Explore common laboratory, research, industrial, and process applications.
The horizontal autoclave, which adopted the way of gravity exchange to release the cold air from the chamber more completely to ensure the reliable sterilization. The control system automatically adjusts the steam inlet and outlet according to chamber temperature during sterilizing. This unit is an ideal equipment for clinics, scientific research institutes and other organizations to sterilize surgical instruments, fabric glasses, and the culture media etc.