Get Quote ▼
Laboratory Horizontal Autoclave BAHZ-301
Horizontal Pressure Steam Sterilizer
- Automatically controlled the sterilizing process, easy to operate.
- With drying function, suitable for the medical dressing drying.
- With over-temperature, over-pressure auto-protect.
- The door cannot be opened until the pressure in the chamber is reduced to 0.027 MPa. And the unit cannot be started on if the door doesn't close well.
- The safety valve will be open automatically when the inner pressure over 0.24 MPa and the steam would be exhausted the water tank.
- Automatically cut off the power if the water-lack happened, and alarm at the meanwhile.
- The chamber of the sterilizer is made of stainless steel.
- With printer.
Old SKU: BGQ1B1
Specifications
| Model | BAHZ-301 |
| Sterilizing chamber volume | 150L φ440x1000mm |
| Working pressure | 0.22MPa |
| Working temperature | 134°C |
| Temperature adjust range | 40~134°C |
| Time for sterilization | 0~99min |
| Time for drying | 0~99min |
| Heat average | ≤ ±2°C |
| Power | 9KW/380V.50Hz |
| Dimension (mm) | 1400x650x1590 |
| Transport dimension (mm) | 1560x860x1820 |
| G.W/N.W | 422kg / 368kg |
Features
Automatically controlled the sterilizing process, easy to operate.
With drying function, suitable for the medical dressing drying.
With over-temperature, over-pressure auto-protect.
The door cannot be opened until the pressure in the chamber is reduced to 0.027 MPa. And the unit cannot be started on if the door doesn't close well.
The safety valve will be open automatically when the inner pressure over 0.24 MPa and the steam would be exhausted the water tank.
Automatically cut off the power if the water-lack happened, and alarm at the meanwhile.
The chamber of the sterilizer is made of stainless steel.
With printer.
With drying function, suitable for the medical dressing drying.
With over-temperature, over-pressure auto-protect.
The door cannot be opened until the pressure in the chamber is reduced to 0.027 MPa. And the unit cannot be started on if the door doesn't close well.
The safety valve will be open automatically when the inner pressure over 0.24 MPa and the steam would be exhausted the water tank.
Automatically cut off the power if the water-lack happened, and alarm at the meanwhile.
The chamber of the sterilizer is made of stainless steel.
With printer.
Applications
The horizontal autoclave, which adopts the way of gravity exchange to release the cold air from the chamber more completely to ensure reliable sterilization. The control system automatically adjusts the steam inlet and outlet according to chamber temperature during sterilizing. This unit is an ideal equipment for clinics, scientific research institutes and other organizations to sterilize surgical instruments, fabric glasses, and the culture media etc.