Laboratory High Speed Refrigerated Centrifuge BCBHR-208

Table Top High Speed Universal (refrigerated) Centrifuge, Table Top High Speed Refrigerated Centrifuge
  • 1. It is Refrigerated centrifuge .Widely used for laboratory, chemistry and hospital.
  • 2.Pre-cooling design, 10 kinds of acceleration and deceleration
  • 3. More than 10 rotors for your choice
  • 4. High speed, low noise, compact design and small vibration
  • 5. User-friendly LED display provides speed, time and temperature parameters.
  • 6. Brushless frequency motor which in great torque, no powder pollution, free maintenance, quick in speed up and down.
  • 7. Imbalance sensor and over speed sensor, the centrifuge body is made of high-quality steel, very safe.
Old SKU: BFH1BZ1
Specifications Features Accessories For Purchase Manual Get Quote

Specifications

ModelBCBHR-208
Max. Speed16000 rpm
Max. RCF27170xg
Max. Capacity4x300ml
Time Range0~99min59sec
RPM/RCF ConvertYes
Noise≤ 55dBA
Speed Accuracy±20rpm
Acc/Dec10 Kinds
Temperature accuracy±1°C
Temperature range-20°C-40°C
Power supplyAC 220V/110V 50HZ/60HZ
CertificatesCE,ISO & Calibration report are available

Features

1. It is Refrigerated centrifuge .Widely used for laboratory, chemistry and hospital.
2.Pre-cooling design, 10 kinds of acceleration and deceleration
3. More than 10 rotors for your choice
4. High speed, low noise, compact design and small vibration
5. User-friendly LED display provides speed, time and temperature parameters.
6. Brushless frequency motor which in great torque, no powder pollution, free maintenance, quick in speed up and down.
7. Imbalance sensor and over speed sensor, the centrifuge body is made of high-quality steel, very safe.

Accessories For Purchase

Name
Max Speed (rpm)
Max Volume (ml)
Max. RCF (xg)
Swing rotor rack (aluminium alloy)
Swing buckets (round cup) (aluminium alloy)
4000
4x300ml
3180
Swing buckets (square cup) (aluminium alloy)
4000
4x300ml
3150
Swing buckets (aluminium alloy)
4000
4x24x7ml
3150
Swing buckets (aluminium alloy)
4000
4x24x5ml
2750
Swing buckets (aluminium alloy)
4000
4x16x10ml
3150
Microplate rotor
4000
2x4x96 well
2910
Swing rotor rack (stainless steel)
Swing buckets (stainless steel)
5000
4x1x50ml
4730
Swing buckets (stainless steel)
5000
4x1x100ml
4730
Swing buckets (stainless steel)
4000
4x2x100ml
3020
Swing buckets (stainless steel)
4000
4x2x50ml
3020
Swing buckets (stainless steel)
4000
4x8x15ml
3200
Swing buckets (stainless steel)
4000
4x6x15ml
3200
Swing buckets (stainless steel)
4000
4x4x10ml
2770
Swing buckets (stainless steel)
4000
4x4x7/5ml vacuum tube adapter
2360
Swing buckets (stainless steel)
4000
4x6x10ml
2770
Swing buckets (stainless steel)
4000
4x6x7/5ml vacuum tube adapter
2360
Swing buckets (stainless steel)
4000
4x8x10ml
2770
Swing buckets (stainless steel)
4000
4x8x7/5ml vacuum tube adapter
2360
Swing buckets (stainless steel)
4000
4x16x5ml
vacuum tube
2520
Swing buckets (stainless steel)
4000
4x16x7ml vacuum tube
2880
Swing buckets (stainless steel)
4000
4x12x10ml vacuum tube
2880
Fixed Rotor
16000
4x8PCR
15760
Fixed Rotor
16000
6x8PCR
24370
Fixed Rotor
16000
8x8PCR
17480
Fixed Rotor
16000
12x8PCR
26090
Fixed Rotor
15000
40x0.5ml
22920
Fixed Rotor
16000
12x1.5/2ml
17940
Fixed Rotor
16000
24x1.5/2ml
23440
Fixed Rotor
16000
30x1.5/2ml
27170
Fixed Rotor
16000
48x1.5/2ml
21700
Fixed Rotor
16000
16x5ml
22200
Fixed Rotor
16000
6x10ml
21500
Fixed Rotor
14000
12x10ml
21200
Fixed Rotor
14000
16x10ml
22610
Fixed Rotor
14000
8x15ml
20630
Fixed Rotor
12000
12x15ml
17060
Fixed Rotor
5000
24x15ml
3500
Fixed Rotor
5000
30x15ml
3830
Fixed Rotor
15000
6x30ml
21880
Fixed Rotor
12000
12x30ml
17640
Fixed Rotor
14000
6x50ml(falcon)
21850
Fixed Rotor
12000
8x50ml(falcon)
18200
Fixed Rotor
12000
10x50ml(falcon)
11240
Fixed Rotor
14000
6x50ml(round)
21730
Fixed Rotor
12000
8x50ml(round)
17830
Fixed Rotor
14000
4x85ml
21960
Fixed Rotor
12000
6x85ml
17750
Fixed Rotor
9000
8x85ml
11160
Fixed Rotor
14000
4x100ml
20220
Fixed Rotor
12000
6x100ml
16390
Fixed Rotor
9000
8x100ml
11120
Fixed Rotor
4000
12x100ml
2970
Fixed Rotor
5000
4x250ml
6960
Fixed Rotor
6000
6x250ml
9510
Swing Rotor
15000
4x5ml
19920
Swing Rotor
12000
4x30ml
20090
Swing Rotor
10000
4x50ml
16240
Vertical rotor
16000
16x5ml
16450
Vertical rotor
14000
8x30ml
19750

Operating Manuals

Download Manual (PDF)

1. Model and name
2. Application
3. Features and specifications
4. Technical data
5. Matched Rotor
6. Working principle
    6.1 The principle of the centrifugation
    6.2 How to calculate the relative centrifugal force (RCF)
    6.3 The confirmation of centrifugal time
7. Unpacking the centrifuge
8. Installation
9. Operation
    9.1 Plug in the centrifuge
    9.2 Open the cover
    9.3 Install the rotors
    9.4 Close the cover
    9.5 Contents in the showing window
    9.6 set parameters
    9.7 Start
    9.8 Stop
    9.9 Open the cover
10. Other function
11. Note
12. Warranty Policy

Safety Notices:

We appreciate your business with our Instrument. To prevent any potential accident, please operate centrifuges according to the following safety protocol.

1. Unplug the main power cord, when performing maintenance or when centrifuge is expected not being used for a long period of time.

2. Load the rotor with samples arranged symmetrically. Opposing tubes must be of equal weight. If necessary, use "water blank" tubes to balance sample tubes of unequal weigh. Do not conclude that tubes are balanced by sight over volume. Use the pan balance provided in the centrifuge room for balancing tubes in rotors for the centrifuge.

3. Never exceed the maximum speed posted for the rotor!

4. Never use the rotor that appears damaged (e.g. O-rings missing, scratched, corroded, and cracked).


Thank you!

1. Model and name

BCBHR-208 Tabletop high speed refrigerated centrifuge

2. Application

Tabletop high speed refrigerated centrifuge is widely used in the fields of clinic medicine, biochemistry, laboratory, genetic engineering and radio immunity, best choice to all labs of science units and hospitals.

This centrifuge is in accord with national standard GB4793.7-2001 and international standard IEC 61010-02-2.

3. Features and specifications

Brushless frequency motor and digital display which indicates the speed, time and temperature.

Frame is 3 tiers protection steel jacket, and with the stainless steel chamber. Electronic lock and pneumatic spring and automatic locked cover can assure the security.

Small vibration, low noise and beautiful design. Adopt advanced CPU control system realizing microprocessor control, it can control rotate speed, temperature and relative RCF, digital display.

4. Technical data

Technical Parameters:

Max speed:

16000rpm

Max RCF:

27170xg

Max volume

4x300ml

Noise:

≤58dBA

Timer

0~99h59min

Net weight:

118KG

Dimension(HxDxW):

640x665x420mm

Power supply

AC 220V/110V 50/60HZ 10A

Temperature Range:

-20°C~40°C

Temperature Accuracy

±1°C

Speed accuracy:

±20rpm

Package

wooden box

Table 1

5. Matched Rotor

Many rotors can be chosen to meet the different centrifugal requirements

Main technical parameters of the rotors:

Rotor No.

Rotor type

Volume(ml)

Speed

(r/min)

RCF(xg)

05133

Angle rotor

16000

4x8PCR

15760

05134

Angle rotor

16000

6x8PCR

24370

05135

Angle rotor

16000

8x8PCR

17480

05136

Angle rotor

16000

12x8PCR

26090

05106

Angle rotor

15000

40x0.5

22920

05101

Angle rotor

16000

12x1.5/2

17940

05102

Angle rotor

16000

24x1.5/2

23440

05103

Angle rotor

16000

30x1.5/2

27170

05104

Angle rotor

16000

48x1.5/2

27170

05107

Angle rotor

16000

16x5

22020

05109

Angle rotor

16000

6x10

21500

05110

Angle rotor

16000

12x10

25800

05111

Angle rotor

14000

16x10

22610

05113

Angle rotor

14000

8x15

20630

05114

Angle rotor

12000

12x15

17060

05140

Angle rotor

5000

24x15

3500

05141

Angle rotor

5000

30x15

3830

05117

Angle rotor

15000

6x30

21880

05118

Angle rotor

12000

12x30

17640

05120

Angle rotor

14000

6x50 Falcon

21850

05122

Angle rotor

12000

8x50 Falcon

18200

05124

Angle rotor

9000

10x50 Falcon

11240

05145

Angle rotor

4000

24x50

2940

05121

Angle rotor

14000

6x50 round

21730

05123

Angle rotor

12000

8x50 round

17880

05125

Angle rotor

14000

4x85

21960

05126

Angle rotor

12000

6x85

17750

05127

Angle rotor

9000

8x85

11160

05128

Angle rotor

14000

4x100

20220

05129

Angle rotor

12000

6x100

16390

05130

Angle rotor

9000

8x100

11120

05148

Angle rotor

4000

12x100

2970

05131

Angle rotor

8000

4x250

9090

05132

Angle rotor

7000

6x250

8050

05193

Angle rotor

12000

24 capillary

15800

05224

Swing rotor

15000

4x5

19920

05225

Swing rotor

12000

4x30

20090

05226

Swing rotor

10000

4x50

16240

05619

Swing rotor

4000

4x300ml round cup

3180

05620

Swing rotor

4x300ml square cup

3150

05623

Swing rotor

4x24x5ml

2840

05622

Swing rotor

4x24x7ml

3140

05621

Swing rotor

4x18x10m

3140

05211

Swing rotor

4000

4x250ml Corning bottle

3260

05214

Swing rotor

4000

2x4x96 well

2910

05629

Swing rotor

5000

4x1x50ml

4730

05630

Swing rotor

4x1x100ml

4730

05635

Swing rotor

4000

4x2x100ml

3200

05634

Swing rotor

4x2x50ml

3200

05640

Swing rotor

4x12x10ml

2880

05636

Swing rotor

4x12x7ml

2760

05637

Swing rotor

4x12x5ml

2480

05631

Swing rotor

4x8x10/15ml

3200

05632

Swing rotor

4x6x10/15ml

3200

05639

Swing rotor

4x16x5ml

2530

05638

Swing rotor

4x16x7ml

2890

Table 2

6. Working principle

6.1 The principle of the centrifugation

Centrifuge will produce RCF during operation. Due to sedimentation caused by RCF make the subject dangling in the solution to form precipitation. The substance of the more proportion turned the direction of the largest radius rotor, the lighter substance is on heavier substance and let the subjects of different proportion to be separated hierarchically.

6.2 How to calculate the relative centrifugal force (RCF)

Centrifugation is depending on the RCF, RCF is depending on the speed and centrifugal radius, the formula of calculating the RCF as follows:

Thank you!, BCBHR-208 Tabletop high speed refrigerated centrifuge, Tabletop high speed refrigerated centrifuge is widely

The transfer coefficient 11.2 is a approx value, which is calculating according acceleration of gravity(1g = 9.81m/s2)

6.3 The confirmation of centrifugal time

Same RCF, centrifugation time is inversely proportional to centrifugal solution's proportion description. The more of the proportion, the less of the time. The less of the proportion, the more of the time.

Same solution, centrifugation time is inversely proportional to RCF. The bigger RCF, the less of the time. Contrary, the smaller RCF, the more of the time.

Same RCF, centrifugation time is related to Min centrifugal radius, longer basket(test bottles) require a longer centrifugation time.

Therefore, the separation time is difficult to calculate. Usually it is decided by the general test.

7. Unpacking the centrifuge

7.1 Check the package before opening the packing box

7.2 Examine the Centrifuge for any shipping damage. If any damage was found, please contact our service department.

8. Installation

8.1 The work table should be smooth and stable, the four feet of the centrifuge should touch the surface of the work table firmly

Thank you!, BCBHR-208 Tabletop high speed refrigerated centrifuge, Tabletop high speed refrigerated centrifuge is widely Warning : In order to ensure safety, please keep 30cm space around the instrument, and stay out of the safety space in operation, do not store any inflammable and any other dangerous goods in the safety space.


8.2 Electrical source should be 220V/110V Single phase, with independent earth line

Thank you!, BCBHR-208 Tabletop high speed refrigerated centrifuge, Tabletop high speed refrigerated centrifuge is widely Caution! Error voltage or the voltage over 10% will damage

the instrument. You need to check the voltage before connect the power.


8.3 This instrument only can be used indoor and it is better to operate under 20°C (constant temperature) condition. maximum relative humidity is 80% for 31°C, while 50% for 40°C, and avoid placing the centrifuge under heat producer(e.g sunshine,heating pipe and radiator)

Thank you!, BCBHR-208 Tabletop high speed refrigerated centrifuge, Tabletop high speed refrigerated centrifuge is widely Caution! In order to assure ventilation effect, you should keep enough space for centrifuge devices. Overheating and poorly ventilated room will damage the instrument.


8.4 Use the attached power cord

Thank you!, BCBHR-208 Tabletop high speed refrigerated centrifuge, Tabletop high speed refrigerated centrifuge is widely Danger: Centrifuge rear over with power socket !, the security identity is enclosed. socket is 220V/110V, be careful when connecting the socket.

9. Operation

9.1 Plug in the centrifuge

There is a switch on the lower right side, on pressing the switch, the compressor starts to work, the digital tube on the panel will light; now the centrifuge is electrified.

9.2 Open the cover

There is a "open the lock" button on the controlling board, as the following diagram, press the "open the lock" button, the lock will be unlocked, pull the cover in upward direction, the gas spring will help you open the cover.

8.4 Use the attached power cord, Danger: Centrifuge rear over with power socket !, the security identity is enclosed. socket

Figure 1

9.3 Install the rotors

(a) you should check whether the rotors have crack and corrosive maculation(especially the bottom of the centrifugal hole) every time before putting them into use. The rotors which has corrosive maculation are forbidden to use, the rotors which beyond the warranty time are also forbidden to use, there is a in the of the centrifuge。

(b) Install the rotor correctly: (pay attention to this part carefully)

8.4 Use the attached power cord, Danger: Centrifuge rear over with power socket !, the security identity is enclosed. socket

Figure 2

8.4 Use the attached power cord, Danger: Centrifuge rear over with power socket !, the security identity is enclosed. socket

Figure 3

8.4 Use the attached power cord, Danger: Centrifuge rear over with power socket !, the security identity is enclosed. socket

Figure 4

Take out the sleeve expension screw from the centrifuge chamber, put the sleeve expension screw into the motor shaft. Rotating with the wrench from closewise with 1-2 circles,then put the rotor. Check the sleeve expension screw to make sure it is very loose before putting into rotor. That is because only when the sleeve expension screw is very loose,the rotor can be fully installed down to the shaft which is correctly installed. If the rotor is installed fully: move the rotor up and down from the shaft,you could hear "bang bang..." sound.If you find the sleeve expension screw is tight and the rotor can not be installed down fully,rotating with the wrench from anticlosewise 3-4 circles to loose the screw and move the rotor up and down to check,if you can hear"bang bang",it is correct,if not,continue to loose the screw till the rotor can be fully installed down to the shaft. Only after the rotor is fully installed down to the shaft,then you can tighten the rotor.

(c)adding test liquids into the centrifugal tubes(about 75% of the tube capacity) and then weighing them with the balance, the weight error of every tube should be less than 2 grams, if it is micro capacity tube, checking whether them are in the same level with your eye.

(d)the input centrifugal tubes should be even. The tubes input improper, unserious weigh the tubes and imbalance working will result in accidents.

(e)fix the covers of the rotors and fasten the screw, checking whether the "O" shape seal is damaged and in the slot.

9.4 Close the cover

Close the cover gently, the cover will lock automatically, if it is closed unwell, the engine won't work when you push the "start" button, the screen will show "E-1", it means that the cover is not closed.

9.5 Contents in the showing window

A: rotors NO. B: speed/relative centrifugal force (RCF)

C: time/break down D: temperature E: acceleration

F: deceleration G: rotors NO. Light H: speed light

I: relative centrifugal force (RCF) light

8.4 Use the attached power cord, Danger: Centrifuge rear over with power socket !, the security identity is enclosed. socket

Figure 5

(A)rotors NO.

It shows the last 2 numerals of the rotors number, it can fully meet the requirements of every kinds of rotors equipped with this machine.

(B)speed/RCF

It shows 5 numerals, it shows 3 kinds of parameters, the first one is speed value; the second one is RCF value, the third one is the program number which stored or in using.

(C) time

It shows the time value and break down situation, the break down number as the follows:


Break down

Cover unclosed

Motor problem

Non-stop

Tempe transducer problem

Parameter receiving problem

Parameters confirming problem

Over speed

display

E-1

E-2

E-4

E-5

E-6

E-7

E-8

Table 3

(D)temperature

It shows the temperature value.

(E)acceleration and deceleration

It shows 10 kinds of speed NO. In one numeral, the time spends on accelerating and decelerating is between 2-10minutes. The bigger of the numeral in showing, the shortest of the time spends on accelerating and decelerating.

9.6 set parameters

There are 10 buttons on the controlling board (just as the following diagram),

Table 3, (D)temperature, It shows the temperature value., (E)acceleration and deceleration, It shows 10 kinds of speed NO.

Figure 6

"ⅰ"open light "ⅱ"start light "ⅲ"stop light

(a) Set button

You can set the "Rotors number", "speed","Temerature","speed acceleration" and "speed deceleration" transferable with this button and the "△""▽" button. For example: Push the "set" button for two times when the centrifuge is in shut down status, the "speed" display will flash, then you can set speed use the "▽""△"button. The speed will flash two times to be confirmed automatically (in the process of flash, don't push any button) you can set all the parameters like this way.

(b)△button and▽button

Push the△button and hold on, the figure will become bigger and bigger, click the△button,the figure will become bigger one by one.

Push the▽button and hold on , the figure will become smaller and smaller, click▽button, the figure will become smaller one by one.

(c)"RCF" button,set the RCF.

Note: Press "RCF" button,the speed window will show RCF. Press the "RCF" button the second time,it will be back to show Speed. The RCF value comes with a dot to show,while speed value doesn't,for example,17180g the window will show 17180., at the same time,the RCF light is a red light;11000rpm,the window will show 11000,at the same time,the speed light is a green light.

(d)"Save"button,save the program,10 programs can be stored.How to set and save programs: Press "call" button,the speed window will show P0 or P1...P9,press △button and▽button to change from P0-P9.Now we set Program 0,when it shows P0,press "set" button,to set speed,rotor No.,time,temperature,acceleration/deceleration according to the above way.When you finish,press "save" button two times to save the program you set.

(e)"Call"button,call the program stored.press △button and▽button to change from P0-P9.

how to calculate the centrifugal time:The calculation of the centrifugal time is in direct ratio with the RCF while in inverse ratio with the density of the liquids. The centrifugal time depends on the maximum RCF and minimum radius; the long bucket will inevitably result in long centrifugal time. The centrifugal time is hard to calculate, it is mainly depending on the experiment.

9.7 Start

Press the "start" button, the green light beside the "start" button will on, the centrifuge will start to work according the parameters you set. Centrifugal chamber temperature by cold hot in turn way in establishment temperature +/-2°C In scope automatic control temperature. The time parameter starts the countdown.

9.8 Stop

It will cut off the electricity automatically in the process of operation when the centrifugal time is 0, the red light will on , it will decelerating according the parameters you set, when you hear the buzz sound the rotors will stop, you can open the cover now. If you want to stop the machine, you should press the "stop" button, the machine will stop according the above procedure.

9.9 Open the cover

You can open the cover till the "ⅰ"open light on .

10. Other function

10.1 over speed protection:for safe operation of this machine, the following protection for every kind of rotor is made in the program:

① if the speed set by the operator exceed the maximum speed of the rotor, it can't work when you press the "open" button, you will see "E-8" in the break down window.

② if the speed gets out of control and exceeds the maximum speed of the rotor for 500r/min, it will stop automatically and you will see "E-7" in the break down window.

Warning:over speed set by the operator is forbidden!Which severely break the operational rules and will result in accident, which can not be identified, so the duty of the accident is fully on the operator, In case of accidents, the following operation is forbidden:

For example: the maximum speed is 3500r/min for NO.3 rotor, but the operator mistakes it for NO.1 rotor, which maximum speed is 5000r/min, if the operator set the speed at 5000r/min , it will working at the speed of 5000r/min, then severely accidents will be happened.


10.2 transferable showing of the RCF :the main parameter which set in the program is speed, the "speed" light will on, if you want to know the RCF in the operation, just press the "set" button, the "RCF" light will on, now the figure in the "speed" window is RCF. If you only know the RCF parameter of the test liquids, you can set the RCF as the main parameter; you can set it according the following procedure: press the "set" button, the "speed" light will flash, the RCF light will on, input the RCF parameter, and then press the "open" button, the machine will operate according the RCF parameter. If you want to know the speed in the operation, press the "set" button, the "speed" light will on, the figure showing in the "speed" window is speed.


10.3 memory function:When all the parameters are set, they will be memorized by the machine. The parameters in the window are what you set last time when you restart the machine.


10.4 this machine has the function of self-diagnosis, When the machine meets the following questions, it will cut off automatically; you are allowed to restart it till the problem is solved.

① the cover unclosed

② over speed break down, when the speed exceeds the stipulated maximum speed for 500/min, it will cut off.

③ temperature measuring break down

④ speed transducer break down

⑤parameters set error

Except the "rotors NO." all the other parameters you can change in the process of operation, it will work according the changed parameters.


10.5 The switch of the cover will be off electricity automatically for safe operation, even you press the "open" button, and it can't open. Press the "open" button, you can open the cover till the machine stops working.


10.6 When the cover is closed or the machine cuts off suddenly, and you want to take out the test tubes, then you can insert the 5(mm) wrench attached with the machine into the engine, which is in the front bottom of the machine, turn around, the cover will open.

11. Note

11.1 The rotor which has crackle is forbidden to use, or accidents will be happened

11.2 The corrosive rotor is forbidden to use.

11.3 The rotor which beyond the warranty time is forbidden to use, aluminum rotor has a 5-year life time. It can be used for 3000 times and 2000 hours. When the rotor is used for 5 years or 3000 times or 2000 hours, then it can't be used anymore. It has attained its usage age.

11.4 The time between cut off and plug in must be more than 3 minutes, or the compressor will be damaged.

11.5 When repair the machine or it won't be put into use for a long

time, you should dismantle the plug.

11.6 You are forbidden to open the cover before the rotor stops, and you also can't stop the rotor with your hand.

11.7 When the rotors damaged you can only move the centrifuge for 30(cm), make sure no dangerous subjects within 30 (cm) around the centrifuge.

11.8 The operator can't lean on the centrifuge when it is in operation, non-worker can't stay around the centrifuge.

11.9 You should care for the overflowed harmful substance when open the rotor cover or clean the centrifugal chamber.

11.10 You should put up the note on your work place.

12. Warranty Policy

1. We have one -year warranty on our all products

2. After the machine fixed, our professional technician will file it and keep track of the usage of the machine.

3. We will pay attention to the feedback of the customers within 24 hours.

4. We won't charge customers any money for repairing the machine in one-year warranty time.

5. We only charge for the accessories on repairing the machine beyond the one-year warranty time.

Get Quote