Heating Incubator BIGP-6203
Heating Incubator - natural convection: The heating incubator provides stable and controllable temperature environment through precise temperature control. It adopts natural convection mode, stable airflow and small temperature fluctuation. It is widely used in bacterial culture, fermentation, breeding, constant temperature culture and other tests. Heating...
- Intelligent:
- It provides two options: colorful touch screen controller and LCD controller. It is easy to operate. (Professional type LCD controller)
- With preset power on, standby and shutdown functions.
- Parameters such as multi-stage temperature, circulating wind speed, time and heating rate can be set and programmed at the same time, simplifying the complicated test process and realizing automatic control and operation.
- Up to 3-Year Product Warranty
- US & EU Compliance Standards
- Door-to-Door Shipping
Technical Specifications
Detailed operating and construction parameters for this model.
| Model | BIGP-6203 |
| Capacity | 124L |
| Temperature Range | RT+5 - 80°C |
| Type | Touch screen |
| Stability | ±0.2°C |
| Uniformity (at 37°C) | ±0.8°C |
| Display Resolution | 0.1°C |
| Max number of shelves | 2(10) |
| Max load per shelf | 20Kg |
| NW | 79Kg |
| Timing Range | 1 - 5999mins |
| Interior Dimension WxDxH (mm) | 520x480x490 |
| Exterior Dimension WxDxH (mm) | 810x588x755 |
| Electrical Requirement | AC220V/50Hz |
| Power Consumption | 550W |
Product Features
Key design, performance, usability, and safety advantages.
Extra Information View additional product guidance, technical notes, diagrams, and supporting information.
Precise temperature control:

The uniformity of the temperature inside the incubator chamber is ≤±10 degree , so that all samples are heated evenly.

Program control mode, linear temperature rise control.

Temperature fluctuation inside the incubator chamber is ±0.2 degree, which ensures the stability of the experiment.

Program control mode, Step heating control.

Ultraviolet sterilization system (option)

No overturning system

Temperature test hole

Sample temperature sensor (optional)
Operating Manual View instructions, operating procedures, safety information, and maintenance guidance.
1.Warranty
2.Contents of package
3.Installation requirements and safety tips
3.1 Installation requirements
3.2 Instruction for Safety
4.Product introduction
4.1 Function introduction
4.2 Specifications
1.Warranty
Thank you for purchasing a Biolab instrument. In normal use conditions, the instrument is guaranteed for a period of 12 months from the date of purchase.
The warranty is valid only if the product is original. It does not apply to any product or parts of it that have been damaged due to incorrect installation, improper connections, improper use, accident or abnormal conditions of operation.
The manufacturer declines all responsibility for damage caused by failure to follow instructions, lack of maintenance and any unauthorized modification
2.Contents of package
The instrument is delivered complete with the following parts:
- Incubator (main unit)
- 2 stainless steel wire shelves
- 4 brackets for shelves
- Power supply cable
- 2 core of fuse
- User manual
3.Installation requirements and safety tips
3.1 Installation requirements
The incubator should be installed in follow conditions:
1. Dry, clean and stable work table with a flat horizontal surface.
2. Respect minimum spaces around instrument 80 cm.
3. Room temperature between 41°F(5°C)and 104 °F(40°C), and relative humidity maximum of 85%.
4. Power supply socket with earth connection.
5. Power feed between 220-240V - 50-60Hz.
3.2 Instruction for Safety 
3.2.1 Danger!
The improper use of this unit may cause property damage and/or personnel injury.
1. The product must be properly electrically grounded (The Hot line or the Neutral line should not be the grounded connection adhere to the product's requirement before using).
2. Please ensure the voltage and frequency of the power supply are compatible with the incubator power requirements prior to use. The fluctuations of the supply voltage shall not exceed 10% of the nominal supply voltage.
3. This unit must use the included electrical cord with a dedicated electrical circuit with a confirmed electrical ground connection.
4. The power switch MUST be in the "OFF" position when power is connected or disconnected from unit.
5. Do not arbitrarily lengthen or shorten the power supply connection wire. Do not modify the power cord in any way.
6. It is prohibited to put in flammable, explosive, volatile, and corrosive substances for drying and baking.
7. Do not touch the chamber door, the chamber body or the surrounding surface when the set temperature is over 176°F(80°C)!
8. Do not put hands or objects into the air inlet or air outlet.
9. The unit should have routine inspections and should be serviced by a qualified service technician when needed.
3.2.2 Warning!
1. Please use the socket connecting with the ground connection to prevent electric shock. If the socket does not have the ground connection, the earth wire must be installed by the qualified electrician. Be sure not to conduct the ground connection through the gas pipe, water pipe, telephone line or lightning rod! This kind of ground connection may cause electric shock due to the incomplete loops.
2. 304 stainless steel material is not acid resistance, so please pay attention to the corrosion prevention measures. Never place corrosive materials inside the unit to prevent damage
3. Do not tension the power supply cord when plug in.
4. The power cord must be removed from receptacle when any of the following occur:
When replacing the fuse;
When the product is waiting for overhaul due to faults;
When the product goes out of service for a long time;
When the product is being moved;
3.2.3 Caution!
1. The incubator should be located on a strong solid surface.
2. Take care when opening and closing the door to prevent damage to delicate internal components.
4.Product introduction
4.1 Function introduction


4.2 Specifications
Natural Convection Incubator
Specification | Requirement | Our Model | Compliance | Deviation | Notes |
Type of System | Fully Automated, Random-Access Clinical Chemistry Analyzer with STAT Functionality | Fully Automated, Random-Access with STAT Functionality | Yes | - | The requirement matches the quoted model. |
Design | Bench Top / Floor Top, Open System | Bench Top design | Yes | - | bench-top model |
Reagent System | Integrated with on-board reagentcooling | 90 refrigerated reagent positions | Yes | - | Reagent cooling is specified as 2-8°C in both systems. |
Reagent Capacity | 32 reagent positions for 10 ml, 25ml, 50 ml bottles | 90 Reagent positions | Yes | - | Our model has a higher capacity (90 positions). |
Reagent Volume per Test | 250 μl per test | 10-350 μl per test | Yes | - | Within acceptable range. |
Sample System | Outer segment with 50 barcode readable positions, inner segment with 12 positions | 60 or 90 sample positions, built-in barcode system available | Yes | - | Meets the requirement with extra capacity in sample positions. |
Sample Volume | 1-30 μl | 1-70 μl | Yes | - | Sample volume exceeds requirement. |
Pipetting System | 1000 μl syringe, programmable in 1 μl steps | 1-70 μl sample syringe, programmable in 0.1 μl steps | Yes | - | The quoted model has more precise pipetting for sample volumes. |
Cuvette Wash | Fully automatic, overflow-level detector | Automatic cuvette washing | Yes | - | It has systems provide automatic cuvette washing. |
Light Source | Quartz-iodine lamp 12V-20W | 12V/30W halogen-tungsten lamp | Yes | - | Light sources are similar. |
Wavelength Range | 340 - 800 nm | 340, 405, 450, 480, 505, 546, 570,600, 630, 700, 750, 800 nm | Yes | - | Matches wavelength range requirements. |
Photometric Range | -0.1 to 3.0 Absorbance, Resolution 0.001 Abs | 0-3.5 Abs, 0.001 Abs resolution | Yes | - | Both systems are in compliance with photometric range. |
Measurement Mode | Kinetic, mono- and bichromatic end-point, two-point measurement | Kinetic, Fixed-time, Rate (Kinetic), 1- and 2-point, non-linear calibration | Yes | - | Model offer a range of measurement modes. |
Quality Control | Up to 15 controls, Westgard rules, Levey-Jennings plots | Real-time QC, Westgard multi-rule, Cumulative Sum Check, Twin Plot | Yes | - | Model offer quality control mechanisms. |
Quality Standard | ISO Certified, CE | CE, ISO 9001, ISO 13485 | Yes | - | Both are compliant with ISO, CE. |