Get Price
Floor Standing Low Speed Refrigerated Centrifuge BKE-3501
Floor Low Speed Large Capacity Refrigerated Centrifuge
Key Features
- RPM increase stepped in 100rpm, with accuracy as high as ±20rpm
- Able to configure acceleration/deceleration time in the permitted range according to the user requirement
- Auto detection of imbalance, over speed, over heat and door lock protection
- Used refrigerant , which meets the environmental protection requirements. The temperature range is -20 ~ 40 DEG C, and the centrifugal cavity temperature can be maintained at 4 degrees at the highest rotational speed.
- Optional self-correction balancing swivel. When swivel is out of balance, error message will be displayed, which will warning and machine will be stopped automatically. No need to balance if the weight difference between blood bags is 3*50g.
- Adopted without carbon brush and variable-frequency motor to save trouble.
- Machine made of steel with three layers of protection, safe and reliable
- Minimal vibration, quiet operation, noise level lower than 65 dB
SKU: BKE-3501
Pricing & Resources
- Up to 3-Year Product Warranty
- US & EU Compliance Standards
- Door-to-Door Shipping
Technical Specifications
Detailed operating and construction parameters for this model.
| Model | BKE-3501 |
| Max. Speed | 6500rpm |
| Max. RCF | 6680xg |
| Max. Capacity | 6x1000ml |
| timing range | 1min~23h59min |
| Temp Range | -20°C~40°C |
| Temp Accuracy | ±2.0°C |
| RPM accuracy | ±20r/min |
| power supply | AC 220±22V,50Hz,30A |
| total power | 4500W |
| Centrifuge chamber diameter | ≤ 65dB(A) |
| dimensions (length x width x height) | 600mm |
| packaging dimensions (length x width x height) | 840x730x1240mm |
| Net Weight | 940x830x1340mm |
| Gross Weight | 260kg |
| 300kg |
Product Features
Key design, performance, usability, and safety advantages.
RPM increase stepped in 100rpm, with accuracy as high as ±20rpm
Able to configure acceleration/deceleration time in the permitted range according to the user requirement
Auto detection of imbalance, over speed, over heat and door lock protection
Used refrigerant , which meets the environmental protection requirements. The temperature range is -20 ~ 40 DEG C, and the centrifugal cavity temperature can be maintained at 4 degrees at the highest rotational speed.
Optional self-correction balancing swivel. When swivel is out of balance, error message will be displayed, which will warning and machine will be stopped automatically. No need to balance if the weight difference between blood bags is 3*50g.
Adopted without carbon brush and variable-frequency motor to save trouble.
Machine made of steel with three layers of protection, safe and reliable
Minimal vibration, quiet operation, noise level lower than 65 dB
Blood bank specific horizontal square cup rotor 6x1000 ml, able to isolate 6 X 400 ml of 5 strip blood bags and 24 X 100ml platelet transferring bag.
Accessories For Purchase View compatible optional accessories and additional items available separately.
| Name | Capacity | Speed | RCF |
| Angle Rotor | 6x250ml | 6500rpm | 6610xg |
| 6x300ml | 6500rpm | 6610xg | |
| 6x500ml | 6000rpm | 6680xg | |
| Swing-out Rotor | 6x1000mlSquare cup(round cup) | 4200rpm | 5100xg |