Get Price

Floor Standing Low Speed Refrigerated Centrifuge BKB-3901

Low Speed Refrigerated Centrifuge
Key Features
  • Large capacity
  • Up to 6x2400ml capacity, it can separate 14.4L samples in one cycle, which greatly improves production efficiency.
  • Safe Structure
  • The overall centrifuge for blood bags has passed MCA ( (Maximum Credible Accident test)
  • After MCA is generated, the centrifuge door lid shall not be opened, and no solid greater than 0.5mm shall blown out of the centrifuge chamber, the position movement shall not exceed 30cm, ensuring the personal safety of the instrument operator to the greatest extent. (MCA test video can be provided)
  • Extensible
  • The system adopts a unified and standard Ethernet communication interface and provides a key parameter point table, to facilitate system expansion and bring data into system monitoring.
  • Programmable
SKU: BKB-3901
Pricing & Resources
  • Up to 3-Year Product Warranty
  • US & EU Compliance Standards
  • Door-to-Door Shipping
Recently Shipped To: 🇹🇿 Tanzania , 🇻🇳 Vietnam , 🇲🇾 Malaysia , 🇹🇼 Taiwan
Get Quote Download Catalog
Specifications Features Accessories For Purchase Get Quote

Technical Specifications

Detailed operating and construction parameters for this model.

ModelBKB-3901
Max. Speed7200rpm
Max. RCF12166xg
Max. Capacity6x1000ml
Angle Rotor Max. Speed7200rpm
Angle Rotor Max. RCF12166xg
Angle Rotor Max. Capacity6x1000ml
Swing Rotor Max. Speed4000rpm
Swing Rotor Max. RCF5600xg
Swing Rotor Max. Capacity6x2400ml(12x400ml or 24x200ml blood bags)
Speed Accuracy±10r/min
Time Setting RangeTwo modes optional:1min to 99h59min and 1s to 99min59s; Default mode: 1s to 99min59s
Timing ModeStart timing after spinning, Start timing after reaching setting speed, Continuous timing, Operation at an appointed time
Temperature Setting Range-20°C to 40°C, Step 1°C adjustable; the fast pre-cooling temperature can reach -20°C
Sample Temperature AccuracyEnsure sample(liquid) temperature accuracy is controlled to ±1°C
Pre-cooling FunctionYes
Temperature Accuracy±2°C
Imbalance ProtectionYes
Rotor IdentificationYes
Compressor UnitHigh Performance Compressor Unit; Environment-friendly refrigerant(R404a)
Computer ControlRS485 or RS232
Protection FunctionImbalance Protection, Rotor Identification, Door Lid Anti Pinch Protection, Motor Overheating Protection, Over-speed Protection and Over-temperature Protection
Noise≤65dB(A)
Power SupplyAC220V±22V 50Hz
Power Consumption7.0kW
Dimension (WxDxH)870x1020x970mm
Packing Dimension (WxDxH)1080x1310x1340mm
Net Weight545kg

Product Features

Key design, performance, usability, and safety advantages.

Large capacity
Up to 6x2400ml capacity, it can separate 14.4L samples in one cycle, which greatly improves production efficiency.
Safe Structure
The overall centrifuge for blood bags has passed MCA ( (Maximum Credible Accident test)
After MCA is generated, the centrifuge door lid shall not be opened, and no solid greater than 0.5mm shall blown out of the centrifuge chamber, the position movement shall not exceed 30cm, ensuring the personal safety of the instrument operator to the greatest extent. (MCA test video can be provided)
Extensible
The system adopts a unified and standard Ethernet communication interface and provides a key parameter point table, to facilitate system expansion and bring data into system monitoring.
Programmable
Save up to 2000 user-defined programs. Users can name each program to distinguish it. Each program can be divided into 5 steps (set speed, time, temperature), to meet the diversified experimental needs.
ACC/DEC Rates
Featuring 10 acceleration and 11 deceleration rates, to prevent the sample from a second emulsion or turbid, and achieve the best centrifugal effect.
Main interface function
In manual mode, the centrifuge parameters can be set quickly, and the G-force and speed can be switched by just touching the key. For the online monitoring of temperature and speed, the stability of temperature and speed during spinning can be viewed through the curve.
Powerful System Setting Function
Running data, error code records, and operation records can be stored through the system setting. Chinese / English operation language is optional. And user authority management and other characteristic functions can be managed as well.
Reliable Material
Centrifuge chamber adopt 2mm thick 316L stainless steel, Housing (3mm Q235 steel), Containment (22mm Q235 steel), Diaphragm indoor lid (2.5mm Q235 steel)
Energy saving
Dynamic compressor control (DCC) technology for optimized cooling performance. When the door lid is opened, the compressor is closed or the sleep time can be set to save energy. Rotor with windshield, little friction, and generates little heat.
Built-in safety
Featuring multiple protection, Such as automatic rotor identification, imbalance protection, over-speed protection, over-temperature protection, motor overheating protection, door lid protection, and so on.
Accessories For Purchase View compatible optional accessories and additional items available separately.
Name
Max. Speed
Max. RCF
Max. Capacity
Angle Rotor
7200
12166
6x1000ml
Adapter
7200
12166
6x500ml
Adapter
7200
12166
6x250ml
Adapter
7200
12166
24x50ml
Adapter
7200
12166
24x50ml(conical)
Swing Rotor Yoke
4000
5600
6x2400ml
Rectangular buckets
4000
5600
6x2400ml
Blood bag adapter
4000
5600
6x2x450ml
6x3x300ml
6x2x500ml
Swing Rotor Yoke
4000
5000
6x2x1000ml
Double positions round buckets
6x2x1000ml

Get Quote