Key Features
  • The optical platform, employing a novel "silicon-aluminum alloy integral casting" structure, is integrally suspended and installed within the main instrument structure.
  • 10cm all-titanium burner head
  • Corrosion-resistant PPS atomizing chamber, supports multiple atomizer extensions
  • Flame foot pedal reading function for easy data reading
  • Comprehensive safety alarm system with dual software and hardware protection
  • Supports oxygen-enriched flame extension, automatic/manual flow extension, etc.
SKU: BEQ-4401
Pricing & Resources
  • Up to 3-Year Product Warranty
  • US & EU Compliance Standards
  • Door-to-Door Shipping
Recently Shipped To: 🇨🇦 Canada , 🇲🇹 Malta , 🇲🇿 Mozambique , 🇷🇸 Serbia
Get Quote Download Catalog
Specifications Features Get Quote

Technical Specifications

Detailed operating and construction parameters for this model.

ModelBEQ-4401
Wavelength Range170-900nm
Spectral BandwidthCu ≤ ±0.02 nm
Wavelength Accuracy≤ ±0.20 nm
Wavelength Accuracy Error0.12 nm
Wavelength Repeatability≤ 0.08 nm
Wavelength Repeatability Result0 nm
Spectral Bandwidth DeviationCu ≤ ±0.02 nm
Shift Slit Positioning Error≤ 0.10 nm
Shift Slit Positioning Error Result0.02 nm
Static Baseline Drift≤ 0.003 Abs / 30 min
Static Baseline Drift Result0.0025 Abs
Dynamic Baseline Drift≤ 0.003 Abs / 15 min
Dynamic Baseline Drift Result0.001 Abs
Static Baseline Noise≤ 0.001 Abs
Static Baseline Noise Result0.0008 Abs
Dynamic Baseline Noise≤ 0.003 Abs
Dynamic Baseline Noise Result0.0002 Abs
Short-Wave Noise≤ 0.01 Abs
Short-Wave Noise Result0.002 Abs
Short-Wave Background≤ 1.5%
Short-Wave Background Result0.8%
Short-Wave High Voltage≤ 650 V
Short-Wave High Voltage Result522 V
Long-Wave Noise Result0.001 Abs
Long-Wave Background Result0.5%
Long-Wave High Voltage Result328 V
Flame Sensitivity - Characteristic Concentration of Cu≤ 0.03 μg/ml/1%
Flame Sensitivity Result0.019 μg/ml/1%
Sensitivity≥ 0.15 Abs
Sensitivity Result0.22 Abs
Apparent Atomization Rate≥ 8%
Apparent Atomization Rate Result12%
Detection LimitCu ≤ 0.003 μg/ml
Detection Limit Result0.0007 μg/ml
D2 Background Correction Capability≥ 60 times
D2 Background Correction Result320 times
Flame PrecisionCu ≤ 0.5%
Flame Precision Result0.25%
Calibration Curve LinearityCu ≤ 5%
Calibration Curve Linearity Result1.80%
Flame Linearity Range≥ 0.6 Abs
Flame Linearity Range Result1.05 Abs
Safety of Flame Atomization SystemYes
Corrosion Resistance Capability of Atomization SystemYes
Data Processing FunctionCorrect and Valid
Insulation Resistance≥ 20 MΩ
Insulation Resistance Result787 MΩ
Leakage Current≤ 5 mA
Leakage Current Result0.66 mA
Electrical and Mechanical Automatic Control FunctionYes
Control Function ResultFlexible, Stable and Reliable
AppearanceYes
Complete Sets of InstrumentYes

Product Features

Key design, performance, usability, and safety advantages.

The optical platform, employing a novel "silicon-aluminum alloy integral casting" structure, is integrally suspended and installed within the main instrument structure.
10cm all-titanium burner head
Corrosion-resistant PPS atomizing chamber, supports multiple atomizer extensions
Flame foot pedal reading function for easy data reading
Comprehensive safety alarm system with dual software and hardware protection
Supports oxygen-enriched flame extension, automatic/manual flow extension, etc.

Get Quote