Double Beam UV Visible Spectrophotometer BKG-901
Double Beam Uv-vis Spectrophotometer
Key Features
- Spectral bandwidth: The spectral bandwidth of the instrument is 1nm / 2nm, which ensures excellent spectral resolution and accuracy required for analysis.
- Ultra-low stray light: excellent C-T monochromator optical system, advanced electronic system, to ensure ultra-low stray light level better than 0.03%, to meet the user's measurement needs of high absorbance samples.
- High-quality devices: The core devices are made of high-quality imported parts to ensure the stability and longevity of the instrument. For example, the core light source device is derived from the long-life deuterium lamp of Hamamatsu in Japan, which guarantees a working life of more than 2000 hours, greatly reducing the maintenance frequency and cost of daily replacement of the light source of the instrument.
- Long-term stability and reliability: The design of the optical dual-beam optical system, coupled with real-time digital proportional feedback signal processing, effectively offsets the signal drift of
- light sources and other devices, ensuring the long-term stability of the instrument baseline.
- High wavelength accuracy: The high-level wavelength scanning mechanical system ensures the accuracy of wavelengths better than 0.3nm and the repeatability of wavelengths better than 0.1nm. The instrument uses the built-in spectral characteristic wavelengths to automatically perform wavelength detection and correction to ensure long-term wavelength accuracy stability.
- Light source replacement is convenient: the instrument can be replaced without removing the shell. The light source switching mirror supports the function of automatically finding the best position. The in-line deuterium tungsten lamp design does not require optical debugging when replacing the light source.
- The instrument is rich in functions: The instrument is equipped with a 7-inch large-screen color touch LCD screen, which can perform wavelength scanning, time scanning, multi-wavelength analysis, quantitative analysis, etc., and supports the storage of methods and data files. View and print the map. Easy to use, flexible and efficient.
SKU: BKG-901
Pricing & Resources
- Up to 3-Year Product Warranty
- US & EU Compliance Standards
- Door-to-Door Shipping
Recently Shipped To:
🇱🇰 Sri Lanka , 🇳🇬 Nigeria , 🇺🇾 Uruguay , 🇲🇿 Mozambique
Get Quote
Download Catalog
Technical Specifications
Detailed operating and construction parameters for this model.
| Model | BKG-901 |
| Wavelength Range | 190-1100 nm |
| Spectral Bandwidth | 1 nm |
| Wavelength Accuracy | ±0.3 nm |
| Optical System | Optical double beam system |
| Monochromator System | Czerny-Turner monochromator |
| Grating | 1200 lines/mm high-quality holographic grating |
| Wavelength Reproducibility | ≤0.1 nm |
| Photometric Accuracy | ±0.002 Abs (0-0.5 Abs); ±0.004 Abs (0.5-1.0 Abs); ±0.3%T (0-100%T) |
| Photometric Reproducibility | ≤0.001 Abs (0-0.5 Abs); ≤0.002 Abs (0.5-1.0 Abs); ≤0.1%T (0-100%T) |
| Stray Light | ≤0.03% (220 nm, NaI; 360 nm, NaNO₂) |
| Noise | ≤0.1%T (100%T); ≤0.05%T (0%T); ≤±0.0005 A/h (500 nm, 0 Abs, 2 nm bandwidth) |
| Baseline Flatness | ±0.0008A |
| Baseline Noise | ±0.1%T |
| Baseline Stability | ≤0.0005 Abs/h |
| Modes | T / A / C / Energy |
| Data Range | -0.00-200.0%T; -4.0-4.0 A |
| Scan Speed | High / Medium / Low / Very Low |
| Wavelength Scan Interval | 0.05 / 0.1 / 0.2 / 0.5 / 1 / 2 nm |
| Light Source | Japan Hamamatsu long-life deuterium lamp; long-life halogen tungsten lamp |
| Detector | Photocell |
| Display | 7-inch large-screen color touch LCD |
| Interface | USB-A / USB-B |
| Power Supply | AC 90-250V, 50/60 Hz |
| Dimensions | 600 x 470 x 220 mm |
| Weight | 24 kg |
Product Features
Key design, performance, usability, and safety advantages.
Spectral bandwidth: The spectral bandwidth of the instrument is 1nm / 2nm, which ensures excellent spectral resolution and accuracy required for analysis.
Ultra-low stray light: excellent C-T monochromator optical system, advanced electronic system, to ensure ultra-low stray light level better than 0.03%, to meet the user's measurement needs of high absorbance samples.
High-quality devices: The core devices are made of high-quality imported parts to ensure the stability and longevity of the instrument. For example, the core light source device is derived from the long-life deuterium lamp of Hamamatsu in Japan, which guarantees a working life of more than 2000 hours, greatly reducing the maintenance frequency and cost of daily replacement of the light source of the instrument.
Long-term stability and reliability: The design of the optical dual-beam optical system, coupled with real-time digital proportional feedback signal processing, effectively offsets the signal drift of
light sources and other devices, ensuring the long-term stability of the instrument baseline.
High wavelength accuracy: The high-level wavelength scanning mechanical system ensures the accuracy of wavelengths better than 0.3nm and the repeatability of wavelengths better than 0.1nm. The instrument uses the built-in spectral characteristic wavelengths to automatically perform wavelength detection and correction to ensure long-term wavelength accuracy stability.
Light source replacement is convenient: the instrument can be replaced without removing the shell. The light source switching mirror supports the function of automatically finding the best position. The in-line deuterium tungsten lamp design does not require optical debugging when replacing the light source.
The instrument is rich in functions: The instrument is equipped with a 7-inch large-screen color touch LCD screen, which can perform wavelength scanning, time scanning, multi-wavelength analysis, quantitative analysis, etc., and supports the storage of methods and data files. View and print the map. Easy to use, flexible and efficient.
Powerful PC software: the instrument is able to connect to the computer via USB. The software supports multiple functions such as wavelength scanning, time scanning, kinetic testing, quantitative analysis, multi-wavelength analysis, etc. There is an optional audit tracking version software that provides user authority management, operation traceability, and meet various requirements in different analysis fields such as pharmaceutical companies.