Get Quote ▼
Cooled Incubator BICL-8102
Cooling Incubator
- Microprocessor control
- • Polished stainless-steel chamber, semicircular arcs at corners for easy cleaning, and the space between the shelves in the chamber is adjustable.
- • Latest PID controller
- • R134a refrigerant, imported compressor
- • Independent temperature-limiting alarm system ensures experiments run safely.(Option)
- • Printer connector and RS485 connector are options which can connect printer and computer
- to record the parameters and the variations of temperature.(Option)
- • There is a 25mm instruction connection hole on the left side of the chamber for easy testing operation and temperature measurement.
Old SKU: BGI1U2
Specifications
| Model | BICL-8102 |
| Temperature Range | -10°C~65°C |
| Display Resolution | 0.1°C |
| Temperature Stability | High Temp ±0.5°C / Low Temp ±1.0°C |
| Electrical Requirement | 220V 50Hz |
| Ambient Temperature | +5°C~35°C |
| Power Consumption | 1100W |
| Interior Dimension (WxDxH)mm | 500x400x600 |
| Exterior Dimension (WxDxH)mm | 650x770x1320 |
| Shelves | 2(pcs) |
| Timing Range | 0~9999min |
| Packing Dimension | 87*79*161 |
| CBM | 1.11 |
| Net Weight | 130.00 |
| Gross weight | 181 |
Features
Microprocessor control
• Polished stainless-steel chamber, semicircular arcs at corners for easy cleaning, and the space between the shelves in the chamber is adjustable.
• Latest PID controller
• R134a refrigerant, imported compressor
• Independent temperature-limiting alarm system ensures experiments run safely.(Option)
• Printer connector and RS485 connector are options which can connect printer and computer
to record the parameters and the variations of temperature.(Option)
• There is a 25mm instruction connection hole on the left side of the chamber for easy testing operation and temperature measurement.
Option:
• Printer
• Independent temperature-limiting Alarm system
• RS485 connector
• Polished stainless-steel chamber, semicircular arcs at corners for easy cleaning, and the space between the shelves in the chamber is adjustable.
• Latest PID controller
• R134a refrigerant, imported compressor
• Independent temperature-limiting alarm system ensures experiments run safely.(Option)
• Printer connector and RS485 connector are options which can connect printer and computer
to record the parameters and the variations of temperature.(Option)
• There is a 25mm instruction connection hole on the left side of the chamber for easy testing operation and temperature measurement.
Option:
• Printer
• Independent temperature-limiting Alarm system
• RS485 connector
Applications
Serve for preserve culture medium, serum, medicine as well as microorganism training and
environmental testing etc.
environmental testing etc.