Get Quote ▼
Concentrator BCON-109
Sample Concentrator
Sample Concentrator (visible) is mainly used for concentrating or preparing sample in batch. Such as drug screening, hormone analysis, liquid phase and mass spectrometry in the analysis of sample preparation. It works by blowing nitrogen, in the surface of sample which is being heated to accelerate evaporating and separating the solvent in the samples...
- Synchronously working with heating by dry bath in the bottom and nitrogen blowing on the surface accelerates liquid evaporation
- and sample concentration.
- The length of a standard gas needle is 150mm.
- The height of the air chamber plate can be adjusted. The unique characteristics: Sample surface in the tube can be observed while concentrating.
Old SKU: BFA1CE1
Specifications
| Model | BCON-109 |
| Temp. Control Range | R.T. +5°C~150°C |
| Temp. Setting Range | 5°C~150°C |
| Temp. Stability@40~100°C | ±0.5°C |
| Temp. Stability@100~150°C | ±1°C |
| Block Temp. Uniformity@100°C | ±0.5°C |
| Block Temp. Uniformity@150°C | ±1°C |
| Temp. Display Accuracy | 0.1°C |
| Heating Speed | <30min (40°C to 150°C) |
| Time Range | 1min ~99h59min |
| Needle Plate Max. Lift Stroke | 285mm |
| Gas-in Joint Outer Diameter | Φ7mm |
| Nitrogen Pressure | <0.1MPa |
| Nitrogen Flow Rate | 0~10L/min |
| Needle Length | 150mm |
| Sample Capacity | 1 Standard Visible Block |
| Voltage | AC 220V / AC 110V, 50/60Hz |
| Power | 400W |
| Fuse | 250V, 3A/6A, Φ5x20 |
| Dimension (WxDxH) | W.220 x D.260 x H.525mm |
| Net Weight | 5.8kgs |
Features
Synchronously working with heating by dry bath in the bottom and nitrogen blowing on the surface accelerates liquid evaporation
and sample concentration.
The length of a standard gas needle is 150mm.
The height of the air chamber plate can be adjusted. The unique characteristics: Sample surface in the tube can be observed while concentrating.
Gas needle is controlled independently. Separately blow of each needle and flow regulating of each needle are available to avoid gas waste.
The entire equipment can be put into ventilation cabinet when the concentration sample in toxic solvents.
Built in overheat protection, automatic fault detection and fault beep alarm devices.
LED displays immediate temperature and diminishing time. Operation is simple and convenient.
and sample concentration.
The length of a standard gas needle is 150mm.
The height of the air chamber plate can be adjusted. The unique characteristics: Sample surface in the tube can be observed while concentrating.
Gas needle is controlled independently. Separately blow of each needle and flow regulating of each needle are available to avoid gas waste.
The entire equipment can be put into ventilation cabinet when the concentration sample in toxic solvents.
Built in overheat protection, automatic fault detection and fault beep alarm devices.
LED displays immediate temperature and diminishing time. Operation is simple and convenient.
Accessories For Purchase
| Images | Spec | Dia. of hole | Name | Block dimension |
![]() | 10 mm x 12 | 10.5 mm | Round bottom | 153.5 x 95.5 x 50 mm |
![]() | 12 mm x 12 | 12.5 mm | Round bottom | 153.5 x 95.5 x 50 mm |
![]() | 13 mm x 12 | 13.5 mm | Round bottom | 153.5 x 95.5 x 50 mm |
![]() | 15 mm x 12(7ml tube) | 15.5 mm | Round bottom | 153.5 x 95.5 x 50 mm |
![]() | 16 mm x 12(10ml/15ml tube) | 16.5 mm | Round bottom | 153.5 x 95.5 x 50 mm |
![]() | 19 mm x 12 | 19.5 mm | Round bottom | 153.5 x 95.5 x 50 mm |
![]() | 20 mm x 12 | 20.5 mm | Round bottom | 153.5 x 95.5 x 50 mm |