Climatic Chamber BCCL-1407
Temperature & Humidity Chamber
- Touch Screen Humidity Chamber
- • Polished stainless-steel chamber, semicircular arcs at corners for easy cleaning, and the height between the shelves in the chamber are adjustable.
- • Homogeneity air circulating system.
- • With temperature and humidity sensor.
- • With programmable controller, large LCD screen.
- • R134A refrigerant, With compressor and fan motor.
- • A 25mm validation port on side of the chamber for easy testing operation and temperature validation.
- • Over temperature and temperature deviation alarms.
Old SKU: BGI1BF7
Specifications
| Model | BCCL-1407 |
| Temperature control range | L:10~100°C |
| Temperature accuracy | 0.1°C |
| Temperature Stability | High temp: ±0.5°CLow temp: ±1°C |
| Humidity control range | 35~95%RH |
| Humidity Accuracy | ±3%RH |
| Power Consumption | 1900W |
| Ambient Temperature | +5~30°C |
| Electrical Requirement | 220V 50HZ |
| Interior Dimension (WxDxH,mm) | 500x400x550 |
| Exterior Dimension (WxDxH,mm) | 650x800x1310 |
| Shelves | 2PCS |
| Packing Dimension | 87*79*161 |
| CBM | 1.11 |
| Net Weight | 130.00 |
| Gross weight | 171 |
Features
Touch Screen Humidity Chamber
• Polished stainless-steel chamber, semicircular arcs at corners for easy cleaning, and the height between the shelves in the chamber are adjustable.
• Homogeneity air circulating system.
• With temperature and humidity sensor.
• With programmable controller, large LCD screen.
• R134A refrigerant, With compressor and fan motor.
• A 25mm validation port on side of the chamber for easy testing operation and temperature validation.
• Over temperature and temperature deviation alarms.
• Compressor over-heat and over-load protections, fan motor over-heat and waterlack protections.
• Independent audible and visible temperature-limiting alarm system ensures
experiments run safely.
• 100 groups with 1000 periods 999 circulations, max timing for each period is 99 hours 59 minutes.
Options:
• Micro printer
• Independent temperature limiting alarm system.
• RS485 connector can connect computer to record and print the parameters and the variations of temperature.
• Polished stainless-steel chamber, semicircular arcs at corners for easy cleaning, and the height between the shelves in the chamber are adjustable.
• Homogeneity air circulating system.
• With temperature and humidity sensor.
• With programmable controller, large LCD screen.
• R134A refrigerant, With compressor and fan motor.
• A 25mm validation port on side of the chamber for easy testing operation and temperature validation.
• Over temperature and temperature deviation alarms.
• Compressor over-heat and over-load protections, fan motor over-heat and waterlack protections.
• Independent audible and visible temperature-limiting alarm system ensures
experiments run safely.
• 100 groups with 1000 periods 999 circulations, max timing for each period is 99 hours 59 minutes.
Options:
• Micro printer
• Independent temperature limiting alarm system.
• RS485 connector can connect computer to record and print the parameters and the variations of temperature.