Get Price

Chromatography BHB-302

Gas Chromatography

The Gas chromatograph system is a new product with an intelligent interconnection system for the new century. It features a large-sized touch-capacitive display for easy and fast switching between functions, and it combines external control with intelligent interconnection to meet specific analytical needs. Additionally, this instrument is equipped with a...

Key Features
  • High-precision gas flow control system with 8th-generation EPC.
  • Built-in one-key factory calibration function.
  • super-silent variable frequency motor system.
  • Bluetooth data transmission and control.
SKU: BHB-302
Pricing & Resources
  • Up to 3-Year Product Warranty
  • US & EU Compliance Standards
  • Door-to-Door Shipping
Recently Shipped To: 🇳🇬 Nigeria , 🇶🇦 Qatar , 🇬🇲 Gambia , 🇳🇵 Nepal
Get Quote Download Catalog
Specifications Features Applications Items Included Get Quote

Technical Specifications

Detailed operating and construction parameters for this model.

ModelBHB-302
General Specifications
--Temperature control zones8 channels
--Temperature control range5°C to 350°C above room temperature
--Increment1°C
--Accuracy±0.01°C
--Program temperature ramp steps32 steps / 33 platforms.
--Number of detectors3 (maximum); options include FID, TCD, ECD, FPD, NPD, PDHID.
Flame Ionization Detector (FID)
--Minimum LOD≤3x10-12 g/s (n-hexane to iso-octane solution)
--Baseline noise≤5x10-14 A
--Baseline drift≤1x10-13 A/30 min
--Linear dynamic range≥10^6
Thermal Conductivity Detector (TCD)
--Minimum LODS ≥ 5000 mV·ml/mg (standard); 8000 mV·ml/mg (high sensitivity) (benzene-toluene solution) (selectable amplification 2, 4, 8 times)
--Baseline noise≤10 μV
--Baseline drift≤30 μV/30 min
--Linear dynamic range≥10^4
Electron Capture Detector (ECD)
--Minimum LOD≤1x10-14 g/s
--Baseline noise≤0.05 mV
--Baseline drift≤0.2 mV/30 min
--Linear dynamic range≥10^3
--Radiation source63Ni
Flame Photometric Detector (FPD)
--Minimum LOD(S) ≤5x10-11 g/s, (P) ≤1x10-12 g/s
--Baseline noise≤0.05 mV
--Baseline drift≤0.3 mV/30 min
--Linear dynamic range≥10^3 (S), 10^2 (P)

Product Features

Key design, performance, usability, and safety advantages.

High-precision gas flow control system with 8th-generation EPC.
Built-in one-key factory calibration function.
super-silent variable frequency motor system.
Bluetooth data transmission and control.
Intelligent program temperature control system.
colorful7-inch LED screen design
FID detector features automatic ignition, flameout, and automatic gas cireuit opening. Achieving intelligent control mode.
Data communication: Ethernet (LAN), RS-232 serial interface, online remote control system data transmission.
Applications Explore common laboratory, research, industrial, and process applications.

The Gas Chromatograph has a wide range of applications, and customized instruments are more scientific. It is used in various industries, such as industrial and mining enterprises, third-party testing organizations, pharmaceutical companies, universities, research institutions, quality inspection, environmental testing, petrochemicals, food safety, and other fields for qualitative and quantitative analysis and testing.

Items Included Review the standard components and accessories supplied with this product.
Image
Name
Description
Chromatography 8 channels 5°C to 350°C above room temperature
Headspace Sampler
The Smart Cloud Platform Multi-Position Headspace Sampler is a newly developed and designed smart functional headspace sampler by our company. It emphasizes intelligent features and visual memory capabilities. With its innovative structural design that utilizes XYZ three-axis movement, it boasts accurate positioning, precise operation algorithms, short trajectory curves, high speed, efficiency, and user-friendly operation. It comes standard with a heating oscillation function.

Get Quote